Skip to main content

How to build a small concrete path

Build a durable concrete path in Australia: excavate 175mm, compact a 75mm DGB20 base, set formwork with 1:50 falls, and place 20 to 25 MPa reinforced slab.

Quick answer

To build a concrete path in Australia, excavate 175 mm, compact 75 mm of roadbase, and pour a 100 mm thick slab using 20 to 25 MPa concrete. Position SL62 mesh on 50 mm bar chairs and maintain a 1:50 cross-fall for run-off compliance under AS 3727.1:2016.

Skill level
Intermediate
Time
1-2 days active work, plus 7 days curing
Trade
Building & Construction
Updated
28 November 2026

Tools you will need

  • Masterfinish 1800mm - Aluminium Screed with Level Vial
  • Marshalltown 141D - 150mm x 75mm Walking Edger
  • Marshalltown QLT 11 x 4.5 inch - Magnesium Float
  • Sakai PC63 or Crommelins CC70 - Petrol Plate Compactor
  • Stabila 196-2 - 1200mm Heavy Duty Spirit Level
  • OX Tools Pro - 150mm x 75mm Stainless Steel Groover
  • Kelso 100L - Heavy Duty Tradesman Steel Wheelbarrow

What is involved in building a small concrete path?

A small concrete path is a practical DIY project for backyard access, garden walkways and side paths, provided you plan the levels properly and work methodically. For most Australian homes, the key to a durable result is good excavation, a compacted base, correct falls for drainage, and proper curing rather than just the concrete itself.

What skill level is required for a small concrete path project?

Intermediate — Estimated time: 1-2 days active work, plus 7 days curing

What tools are essential for constructing a concrete path in Australia?

Tape measure, 5-8 m minimum
String line, string line pins and line level, or a laser level for more accurate falls
Marking paint or builder’s chalk
Shovel, trenching spade and mattock for excavation
Wheelbarrow, 100-130 L
Plate compactor, 60-80 kg class, for compacting subgrade and road base; hire is usually more economical than buying for a one-off job
Hand tamper for tight areas where a plate compactor cannot reach
Circular saw or handsaw for cutting formwork
Drill/driver or hammer for fixing formwork stakes
Spirit level, 1200 mm minimum
Screed board, straight aluminium or timber, 1800-2400 mm long
Concrete mixer, 120-160 L, if hand mixing; hire is generally more economical than purchase unless you do frequent concrete work
Concrete rake or shovel for placing the mix
Magnesium float or wood float for initial finishing
Steel trowel for edge touch-up only; not essential for a broom finish
Edging tool and groover/jointer
Broom with medium bristles for non-slip finish
Bolt cutters or angle grinder for cutting reinforcing mesh
Garden hose with fine spray or pump sprayer for curing
PPE: safety boots, gloves, eye protection, hearing protection, dust mask/P2 respirator, long sleeves and sunscreen

What materials are needed for a durable concrete path in Australia?

Concrete, 20 MPa premixed concrete recommended for consistency; for hand mixing use a general-purpose mix ratio of 1:2:3 (cement:sand:aggregate by volume)
Cement, sand and 10-14 mm aggregate if mixing on site
Road base or crusher dust, 75-100 mm compacted thickness
Formwork boards, typically 100 x 25 mm treated pine or similar straight boards
Timber or steel stakes, 450-600 mm long, for holding formwork
Reinforcing mesh, such as SL62 mesh, optional for very short light-duty paths but recommended for better crack control
Bar chairs, 40-50 mm, to keep mesh off the ground
Expansion joint foam, 10 mm thick, where the path abuts a house slab, existing concrete or other rigid structures
Plastic sheeting or curing compound for curing
Tie wire for securing mesh
Clean water for mixing and curing
Topsoil or gravel for backfilling edges after formwork removal

Typical quantities for a small path:

Concrete volume = Length x Width x Thickness
Example: 10 m long x 900 mm wide x 100 mm thick = 0.9 m³ concrete
Add 10% allowance for waste and uneven ground
Road base for the same path at 75 mm compacted = about 0.68 m³ before compaction allowance

Safety Requirements

Wear safety boots, gloves, eye protection and a P2 dust mask when handling cement and cutting materials
Wet concrete is caustic and can cause cement burns; wash off splashes immediately
Use correct manual handling for cement bags, mesh and formwork; get help for lifting and moving heavy loads
Keep children and pets clear of the work area during excavation, pouring and curing
Check for underground services before digging; use Before You Dig Australia and confirm any local utility requirements
Ensure runoff falls away from the house and does not direct water onto neighbouring property; check local council drainage requirements
Maintain finished concrete levels below weep holes and damp-proof course; as a general rule, keep the path at least 75 mm below weep holes at brick veneer walls
For paths near retaining walls, boundaries, easements or where significant excavation is required, seek engineering or council advice
Concrete work should follow good practice under AS 3600 for durability and placement; if the path will carry vehicles or structural loads, engineering certification is required

Step-by-Step Guide

Step 1: Plan the path size, thickness and drainage

Decide the path width and use. For a garden or side path, 750-1000 mm wide is typical, with 900 mm a practical all-round size. For light foot traffic, 75 mm concrete can work on a well-prepared base, but 100 mm thickness is a safer DIY standard, especially where wheelbarrows, bins or garden equipment will be used.

Plan the fall so water drains away from buildings. A crossfall of 1:80 to 1:100 is suitable for most paths. On a 900 mm wide path, that means a drop of about 9-11 mm from one side to the other.

Step 2: Measure the area and calculate materials

Measure the length, width and thickness to calculate concrete volume:

Length x Width x Thickness = m³

Example:

10 m x 0.9 m x 0.1 m = 0.9 m³ concrete

For road base:

10 m x 0.9 m x 0.075 m = 0.675 m³

Add around 10% for waste, over-excavation and uneven ground. If the total concrete volume is over about 0.3 m³, ordering premixed concrete is usually easier and often better value than hand mixing.

Step 3: Set out the path with string lines

Mark both edges of the path using string lines and pegs. Check the width at several points to keep it consistent. Use a line level or laser level to set the finished height and required fall.

If the path runs beside a house, set the height so the finished surface remains at least 75 mm below weep holes. Also make sure the path does not trap water against walls or fences.

Step 4: Excavate to the correct depth

Excavate all topsoil, roots and soft material. For a standard DIY path, dig to allow for:

75-100 mm compacted road base
75-100 mm concrete

That usually means an excavation depth of 150-200 mm below finished surface level. On soft or reactive ground, dig deeper and increase the base thickness until you reach firm material.

Trim the bottom as evenly as possible. Remove loose spots and fill low areas with compacted base, not with extra concrete.

Step 5: Compact the subgrade and install the base

Compact the natural ground first with a plate compactor. Then place road base in layers no thicker than 50 mm and compact each layer thoroughly. The final compacted base should be 75-100 mm thick and follow the same fall as the finished path.

A firm, well-compacted base is critical. You should be able to walk on it without leaving deep footprints. If the area remains soft after compaction, remove the weak material and replace it with additional compacted base.

Step 6: Install formwork and check levels

Fix 100 x 25 mm form boards along both sides of the path using stakes at roughly 1000-1200 mm centres, closer on curves. Keep the top of the forms at the finished concrete height.

Check:

Width is consistent
Crossfall is correct
Forms are straight and solid
Corners and joints are secure

Any movement in the formwork will show in the finished path, so take the time to get this right.

Step 7: Install reinforcement and isolation joints

If using reinforcing mesh, cut it so it sits inside the formwork with clear cover from the edges. Support it on 40-50 mm bar chairs so it stays off the base during the pour. Do not lay mesh directly on the ground.

Install 10 mm expansion joint foam where the new path meets:

House slabs
Existing concrete
Brick walls
Steps or rigid structures

For a small straight path, control joints should be planned at about 1.2-1.8 m spacing, or no more than about 24-30 times the slab thickness. For a 100 mm thick path, keep joint spacing to roughly 2.4-3.0 m maximum.

Step 8: Prepare the concrete

For best consistency, order 20 MPa premixed concrete for larger jobs. For small hand-mixed jobs, use:

1 part cement
2 parts clean sand
3 parts 10-14 mm aggregate

Add only enough water to make the mix workable. The concrete should hold its shape and not be runny. Too much water weakens the path, increases shrinkage and causes dusting and cracking.

Mix enough labour and tools before you start. Concrete finishing is time-sensitive, especially in hot or windy Australian conditions.

Step 9: Place the concrete evenly

Pour or wheelbarrow the concrete into the forms and spread it with a rake or shovel. Place it slightly higher than the form edges to allow for screeding.

Work from one end to the other without long delays. If hand mixing, keep each batch consistent in water content and finish each section while the concrete is still workable.

Lift the reinforcing mesh slightly as the concrete goes in if needed, but the mesh should already be supported on chairs.

Step 10: Screed the surface to level

Using a straight screed board resting on the forms, draw the screed across the concrete in a sawing motion while moving forward. This levels the surface and removes excess concrete.

Fill any low spots immediately and re-screed. The finished level should match the top of the formwork and maintain the planned fall for drainage.

Step 11: Float, edge and joint the path

Once the bleed water has started to disappear, use a magnesium float or wood float to smooth the surface and compact the cream. Do not finish while water is sitting on top.

Run an edging tool along the formwork edges to round them slightly and reduce chipping. Form your control joints with a groover to a depth of about one-quarter of the slab thickness. For a 100 mm path, make the tooled joint about 25 mm deep.

If you prefer saw-cut joints, wait until the concrete is firm enough and cut them within the recommended time window, usually later the same day or the next morning depending on weather.

Step 12: Apply the final finish

For outdoor paths, a broom finish is the best choice because it provides grip when wet. Lightly drag a damp broom across the surface at right angles to the path direction or across the main direction of travel.

Avoid over-trowelling. A very smooth steel-trowelled finish can become slippery and is not recommended for most external paths.

Step 13: Cure the concrete properly

Proper curing is one of the most important steps. Once the surface is firm enough not to mark, apply curing compound or cover the path with plastic sheeting to hold moisture in.

Cure for at least 7 days where practical. In hot, dry or windy weather, start curing as soon as the finish allows. Good curing improves strength, reduces surface dusting and helps control shrinkage cracking.

Step 14: Remove forms and backfill the edges

Remove the formwork after 24-48 hours, depending on weather and concrete set. Backfill the sides with soil, mulch or gravel and compact lightly so water does not undermine the path edges.

Avoid heavy loads during the early curing period. Light foot traffic is usually fine after 24-48 hours, but wait around 7 days before using wheelbarrows or bins on the path. Full design strength develops over about 28 days.

Common Mistakes to Avoid

1.Pouring concrete onto loose soil or topsoil instead of a compacted base, which leads to sinking and cracking.
2.Using too much water in the mix, which weakens the concrete and causes a dusty, brittle surface.
3.Forgetting the fall, causing water to pond on the path or drain back toward the house.
4.Leaving reinforcement on the ground instead of supporting it on chairs, which makes it far less effective.
5.Skipping control joints and curing, which greatly increases the risk of random cracking.

Pro Tips

For most DIY paths, a 100 mm thick slab over 75-100 mm of compacted road base is a reliable standard.
If the job is larger than about 0.3 m³, order premixed concrete rather than hand mixing; the finish will usually be better and the work much easier.
In hot weather, dampen the base lightly before pouring so it does not suck moisture from the concrete, but do not leave standing water.
Use a broom finish for safety; it is the most practical outdoor finish for Australian homes.
Where the path sits beside a brick house, always keep the finished level below weep holes and slope water away from the wall.

Recommended Tools

Belle Minimix 150 concrete mixer — a proven small mixer for DIY jobs; ideal if you are not ordering premix
OX Pro aluminium screed, 1800-2400 mm — lightweight and straight for levelling small paths accurately
Masterfinish magnesium float, 400-500 mm — good for initial finishing without overworking the surface
Husqvarna or Wacker Neuson plate compactor, 60-80 kg class — excellent for compacting the base; better hired than bought for one project
OX Pro edger and groover set — helps create neat edges and proper control joints for a more professional finish

Frequently asked questions

What is the minimum thickness for a residential concrete path?
A residential concrete path requires a minimum thickness of 75 mm for pedestrian use under AS 3727.1:2016. Paths supporting ride-on mowers, wheelbarrows, or light utility vehicles must be at least 100 mm thick over a 75 mm compacted roadbase foundation.
What concrete strength and mesh do I need for a path?
Residential concrete paths require a minimum 20 MPa compressive strength, though 25 MPa mix ensures superior weather resistance. Reinforce the slab using SL62 or SL72 welded mesh supported on 50 mm plastic bar chairs to maintain elevation within the middle third of the slab depth.
What fall is required for proper drainage on a concrete path?
A concrete path requires an outward cross-fall gradient between 1:50 and 1:100 to shed surface water efficiently. This equates to a 10 mm to 20 mm slope per metre of path width, directing run-off away from residential foundations into garden beds or stormwater drains.
How far apart should expansion and control joints be placed in a path?
Control joints must be spaced at intervals between 1.5 and 2 metres, or no more than twice the path's width. Form or saw joints to a minimum depth of one-quarter the slab thickness within 12 to 24 hours of pouring to eliminate random shrinkage cracking.
How long does a concrete path take to cure in Australian conditions?
Concrete paths take 28 days to achieve specified structural compressive strength, but handle light foot traffic after 24 to 48 hours. Keep the slab wet or covered under plastic sheeting for at least 7 days to prevent rapid moisture loss and surface crazing.
What are the most common mistakes when pouring a concrete path?
Common mistakes include pouring directly onto uncompacted soil, placing steel mesh flat on the ground, and excessive trowelling while bleed water remains. These errors lead to subgrade subsidence, internal corrosion, surface dusting, and structural cracking across the finished pavement.

Written by Bricko, the Building & Construction specialist at VIC.Tools.