Skip to main content

How to install reo mesh in concrete slabs

Learn how to install reo mesh in concrete slabs correctly. Comply with AS 2870 and AS 3600 for bar chair spacing, mesh overlap, and minimum concrete cover.

Quick answer

Reinforcement mesh in concrete slabs must be supported on plastic bar chairs at 700mm to 900mm intervals to achieve 40mm to 50mm minimum concrete cover. Mesh sheets must overlap by at least two cross wires, or 200mm to 225mm, adhering strictly to AS 2870:2011 and AS/NZS 3600:2018 standards.

Skill level
Intermediate
Time
0.5-2 hours per 100 m² (depending on slab complexity)
Trade
Building & Construction
Updated
29 November 2026

Tools you will need

  • Hitachi / Hikoki 24-inch (600mm) Heavy-Duty Bolt Cutters
  • Makita DTR180Z 18V Cordless Rebar Tying Tool
  • DeWalt DWE4120-XE 125mm Heavy Duty Angle Grinder
  • OX Pro Pull-Action Tie Wire Twister
  • Stanley FatMax 8m Heavy Duty Tape Measure
  • Novoplas Concrete Plastic Tipping Bar Chairs (50/65mm)

🧱 Installing Reinforcement Mesh in Concrete Slabs

What is the purpose of installing reo mesh in concrete slabs?

This guide details the correct procedure for installing steel reinforcement mesh in concrete slabs, ensuring compliance with Australian Standards and optimal structural integrity. Proper placement of reinforcement is critical for resisting tensile forces and preventing cracking in concrete.

What skill level is required for installing reo mesh?

Intermediate — Estimated time: 0.5-2 hours per 100 m² (depending on slab complexity)

What tools are essential for reo mesh installation?

Bolt Cutters: Heavy-duty, 600mm or larger, for cutting mesh. Tie Wire Twister/Rebar Tie Tool: Manual or automatic for securing mesh. Tape Measure: 8m or longer, for accurate spacing. Chalk Line: For marking cut lines. Angle Grinder: With metal cutting disc, for precise cuts (optional, but useful). Bar Chairs/Spacers: Plastic or concrete, appropriate height for cover. PPE: Safety glasses, gloves, steel-capped boots.

What materials are needed for reo mesh installation?

Reinforcement Mesh: SL72, SL82, SL92, or SL102 (or as specified by engineer). Tie Wire: 1.57mm annealed black tie wire. Bar Chairs/Spacers: Sufficient quantity to achieve specified concrete cover (e.g., 50mm for ground slabs).

What are the key safety requirements for reo mesh installation?

⚠️ PPE: Always wear safety glasses, heavy-duty gloves, and steel-capped boots. ⚠️ Manual Handling: Reinforcement mesh sheets can be heavy and awkward. Use team lifts or mechanical aids for larger sheets to prevent back injuries. ⚠️ Cutting Hazards: Exercise extreme caution when using bolt cutters or angle grinders. Ensure stable footing and clear work area. ⚠️ Trip Hazards: Keep the work area clear of offcuts and loose tie wire. ⚠️ Site Specific: Adhere to all site-specific safety plans and SWMS.

Step-by-Step Guide

Step 1: Site Preparation and Formwork Inspection

1️⃣ Verify Subgrade: Ensure the subgrade is compacted, level, and free from debris, as per engineering specifications.

2️⃣ Check Formwork: Confirm formwork is correctly installed, braced, and at the correct finished height. All penetrations (plumbing, electrical) should be in place and secured.

3️⃣ Install Vapour Barrier: Lay down a continuous vapour barrier (e.g., 200-micron builders' plastic) with 200mm overlaps, taped securely, to prevent moisture ingress.

Step 2: Marking and Initial Mesh Placement

1️⃣ Reference Lines: Use a chalk line to mark out the intended layout of the mesh sheets, including overlap zones.

2️⃣ First Sheet Placement: Carefully unroll or place the first sheet of reinforcement mesh (e.g., SL82) onto the prepared subgrade/vapour barrier. Ensure it is positioned correctly, allowing for required edge distances.

3️⃣ Edge Clearance: Maintain the specified concrete cover from the edge of the slab. For ground slabs, this is typically 50mm from the formwork.

Step 3: Overlapping and Tying Mesh

1️⃣ Overlap Requirements: Position subsequent mesh sheets to overlap the previous one by a minimum of 225mm (typically 3 squares) or as specified by the engineer (refer to AS 3600 Concrete Structures).

2️⃣ Secure Overlaps: Use tie wire and a tie wire twister to securely fasten the overlapping mesh sheets. Tie every second or third intersection along the overlap to prevent movement during concrete pour.

3️⃣ Corner Reinforcement: For re-entrant corners or areas of high stress, additional corner bars or mesh cut-outs may be required as per engineering drawings.

Step 4: Cutting and Shaping Mesh

1️⃣ Measure and Mark: Accurately measure the required cuts for penetrations, irregular shapes, or slab edges. Mark the cut lines clearly with chalk.

2️⃣ Cutting Mesh: Use heavy-duty bolt cutters to cut the mesh. For more precise or complex cuts, an angle grinder with a metal cutting disc can be used.

3️⃣ Penetration Detailing: Ensure mesh is cut neatly around penetrations and that any required trimming or additional reinforcement (e.g., N12 bars) is installed as per engineering.

Step 5: Installing Bar Chairs/Spacers

1️⃣ Determine Cover: Refer to engineering drawings for the specified concrete cover, which dictates the height of the bar chairs. For ground slabs, this is commonly 50mm or 75mm.

2️⃣ Chair Placement: Place bar chairs evenly under the mesh, typically at 600-900mm centres, or closer in high-traffic areas or where mesh sags. Ensure chairs are stable and will not tip during the pour.

3️⃣ Maintain Uniformity: The goal is to ensure the mesh remains in the top third of the slab depth (for standard slabs) or as specified by the engineer, providing optimal tensile strength.

Step 6: Final Inspection and Engineering Sign-off

1️⃣ Visual Check: Conduct a thorough visual inspection of the entire mesh layout. Verify all overlaps are correct, ties are secure, and bar chairs are properly positioned.

2️⃣ Cover Verification: Randomly check the height of the mesh using a tape measure to ensure the specified concrete cover will be achieved.

3️⃣ Engineer Inspection: Ensure the structural engineer or their representative inspects and approves the reinforcement placement before any concrete is poured. This is a mandatory hold point for structural integrity.

Common Mistakes to Avoid

1.Insufficient Overlap: Failing to overlap mesh sheets by the specified amount (minimum 3 squares or as per engineer) compromises structural continuity.
2.Incorrect Cover: Mesh placed too low (on the subgrade) or too high (at the surface) is ineffective. Too low leads to no tensile strength, too high leads to spalling.
3.Lack of Tying: Not adequately tying overlaps or adjacent sheets allows mesh to move during the concrete pour, leading to incorrect placement.
4.No Engineering Sign-off: Pouring concrete without the engineer's approval on reinforcement placement can lead to costly rework or structural failure.
5.Damaged Vapour Barrier: Punctures or inadequate overlaps in the vapour barrier compromise its effectiveness, leading to moisture issues.

Pro Tips

💡 Pre-cut Tie Wire: Cut tie wire into 150-200mm lengths beforehand to speed up the tying process. 💡 Mesh Roll Management: When unrolling mesh, secure one end with a heavy object or a temporary peg to prevent it from springing back. 💡 Bar Chair Stability: For softer subgrades, use wider-based bar chairs or place a small piece of timber/plastic under standard chairs to prevent them from sinking. 💡 Temporary Walkways: Use timber planks across the mesh to create temporary walkways during the pour, preventing workers from stepping directly on and displacing the mesh. 💡 Order Correct Mesh: Always double-check the engineering drawings for the correct mesh type (e.g., SL72, SL82) and quantity to avoid delays and reordering.

Recommended Tools

🔧 Knipex Bolt Cutters (71 72 610): Superior cutting power and durability for rebar and mesh. 🔧 Max Rebar Tier (RB441T): Significantly speeds up tying, reducing manual effort and time on larger jobs. 🔧 Stanley FatMax Tape Measure (8m): Robust and reliable for accurate measurements on site. 🔧 Makita Angle Grinder (GA9020): Powerful and durable for heavy-duty cutting tasks when bolt cutters aren't sufficient.

Frequently asked questions

How much overlap is required for reo mesh in Australia?
Reinforcing mesh requires a minimum lap splice of two cross wires, generally equating to 200mm to 225mm, or as specified by an engineer under AS/NZS 3600:2018. For ribbed structural mesh like SL72 or SL82, ensuring at least two transverse wire overlaps prevents structural failure and control joint cracking.
What is the correct concrete cover for reo mesh?
Standard residential slabs on ground require a minimum concrete cover of 40mm to 50mm under AS 2870:2011 to prevent steel corrosion. Positioning reinforcement in the top third of the slab profile with 30mm to 50mm top cover best controls surface shrinkage cracking in driveways and flatwork.
How far apart should bar chairs be spaced for reo mesh?
Plastic bar chairs must be spaced between 700mm and 900mm apart on a continuous grid to support reo mesh securely. Chairs must support foot traffic during the pour without deflecting steel downwards. Spacers must sit on solid moisture barriers or blinding concrete without puncturing the damp-proof membrane.
What Australian standards govern concrete slab reinforcement?
Concrete reinforcement installation in Australia is governed by AS 2870:2011 for residential slabs and footings, and AS/NZS 3600:2018 for commercial concrete structures. Steel reinforcement products must also comply with AS/NZS 4671:2019 to verify specified yield strength, ductility classes, and structural compliance before inspection.
What are the most common reo mesh installation mistakes?
The most common mistakes are placing mesh directly on the ground without chairs, pulling it up during the pour, and cutting expansion joints through reinforcement. Using undersized laps, skipping edge beam corner tie-ins, and using incorrect chair heights compromise load transfer and inevitably cause severe slab cracking.
Do you need to tie every reo mesh intersection?
Tying every intersection is unnecessary; securing reo mesh at alternating intersections roughly 400mm to 600mm apart with 1.6mm tie wire is standard. Structural laps require tie wire on both outer edges to prevent displacement when trades walk over reinforcement or when concrete pump hoses discharge.

Written by Bricko, the Building & Construction specialist at VIC.Tools.