How to install timber stair stringers and treads
Install timber stair stringers and treads to NCC 2022 and AS 1684. Master rise and going set-out, stringer cutting, and bracket fixing on decks and stairs.
Quick answer
To install timber stair stringers and treads, calculate rises between 115mm and 190mm and goings between 240mm and 355mm under NCC 2022. Cut stringers maintaining a 90mm minimum throat depth, trim the bottom riser by the tread thickness, and secure to landing joists using engineered structural steel brackets.
- Skill level
- Advanced
- Time
- 1-2 days depending on stair complexity, number of flights, finish requirements and whether the stair is internal or external
- Trade
- Carpentry & Joinery
- Updated
- 28 November 2026
Tools you will need
- Makita HS0600 - 260mm Circular Saw
- Empire EMT2485 - 600mm True Blue Magnetic Box Level
- Milwaukee M18 FUEL - 1/2 Inch High Torque Impact Wrench
- Starrett 505A-12 - ProSite Protractor Miter Rule
- Stanley 0-16-144 - 6-Piece FatMax Chisel Set
- DeWalt DCS334N-XJ - 18V Brushless Jigsaw
- Swanson S0101 - 7-Inch Speed Square
What is involved in installing timber stair stringers and treads?
🪚 Installing Timber Stair Stringers and Treads
Installing timber stair stringers and treads is a precision framing and finishing task that directly affects structural performance, compliance and user safety. For Australian projects including internal fit-outs, external decks and home extensions, the work must be set out accurately, fixed correctly and checked against the National Construction Code (NCC), AS 1684 Residential Timber-Framed Construction, and relevant stair geometry requirements before installation proceeds.
This guide covers professional set-out, cutting, fixing and finishing of timber stair stringers and treads for typical site-built timber stairs, with attention to rise/run consistency, support conditions, durability and finish quality.
What skill level is required for timber stair stringer and tread installation?
Advanced — Estimated time: 1-2 days depending on stair complexity, number of flights, finish requirements and whether the stair is internal or externalWhat tools are essential for installing timber stair stringers and treads?
What materials are needed for timber stair stringers and treads?
Safety Requirements
Step-by-Step Guide
Step 1: Confirm stair geometry, compliance and support conditions
1️⃣ Verify Rise, Going and Compliance Parameters
Measure the floor-to-floor height from the finished lower floor level to the finished upper floor or landing level. Confirm whether tread finishes, tile build-ups, underlay or external decking boards are included in the final level calculation.
Check approved plans, engineering details and NCC stair requirements for:
Consistency is critical. The allowable variation between risers and goings is tightly controlled, so do not start fabrication until finished levels are locked in.
💡 Pro tip: Always calculate from finished floor level to finished floor level, not structural substrate to substrate. A missed 10-20 mm floor finish will throw out the whole flight.
Step 2: Select suitable stringer and tread material
2️⃣ Choose Structural and Finish-Appropriate Timber
Select stringer stock based on span, exposure, stair width and loading. For many site-built stairs, structural stringers are cut from 290x45 mm or 240x45 mm stock, but wider or longer flights may require engineered design, larger sections or steel support integration.
For external stairs, use:
For internal stairs, use:
Reference AS 1684 for timber framing principles, and engineer-specific details where the stringer acts as a primary structural member beyond standard residential framing assumptions.
Step 3: Calculate the number of rises and exact tread set-out
3️⃣ Set Out the Stair Accurately Before Cutting
Divide the total floor-to-floor height by the target rise to determine the number of risers. Adjust until each rise is compliant and equal. Then determine the going and total run based on plan space, pitch limits and stair use.
Mark your calculations clearly:
For open-tread or external deck stairs, confirm how the tread thickness affects the first and final rise. For housed or closed-riser internal stairs, account for finished tread and riser build-up in your set-out.
💡 Pro tip: On cut stringers, the bottom plumb cut and top plumb cut are rarely identical to the internal step pattern once finished flooring and tread thickness are considered. Set these separately.
Step 4: Mark out the stringer
4️⃣ Transfer Rise and Going to the Stringer Stock
Use a framing square with stair gauges locked to the exact rise and going. Start at the lower end of the stringer stock and mark each tread and riser intersection progressively along the timber.
Clearly indicate:
Avoid overcutting into internal corners. Cut stringer notches reduce member capacity, so maintain adequate throat depth through the stringer. If the notching leaves insufficient material, increase member depth or change to a housed or engineered stair design.
For multiple stringers, use the first fully checked stringer as the master template only after dry verification.
Step 5: Cut the first stringer and proof it
5️⃣ Fabricate a Master Stringer and Test Fit
Cut the waste side of each line with a circular saw, stopping just short of the intersection to avoid overcutting. Finish corners cleanly with a jigsaw or handsaw.
Offer the first stringer into position and check:
Check that the first and last rises remain correct once tread thickness and floor finishes are included.
Do not cut the remaining stringers until the first one has been physically test-fitted and confirmed.
💡 Pro tip: If the stair is exposed architectural work, machine or sand the saw cuts and arrises on the master before templating the rest. It saves substantial finishing time later.
Step 6: Duplicate remaining stringers and prepare supports
6️⃣ Produce Matching Stringers and Structural Backing
Clamp the approved master stringer onto the remaining stringer stock and trace accurately. Cut each one identically and label left, right and centre positions if the stair width requires multiple stringers.
Typical support spacing depends on tread thickness and stair width. As a general trade approach:
Install any supporting members including:
For deck stairs, tie supports into the primary deck structure rather than only into decking boards or trim elements.
Step 7: Fix the stringers in place
7️⃣ Install Stringers Plumb, Parallel and Fully Supported
Position each stringer and fix the top ends first using the specified bracket, cleat, bolts or structural screws. Then fix the lower bearing point to the landing, slab, bearer or support frame.
Check:
Use non-compressible packers only where required, and avoid packing that creates point loads or future movement. Re-check stringer spacing before proceeding to tread installation.
For external applications, keep stringers clear of direct soil contact and provide drainage and ventilation around the lower end.
Step 8: Install risers where required
8️⃣ Fix Risers Before or With Treads Depending on Stair Type
For closed-riser stairs, cut risers to fit tightly between stringers or into housings depending on the design. Fix with adhesive and screws from concealed positions where possible, maintaining a straight face line and consistent junction to the tread above and below.
If the stair is a joinery-grade internal stair, pre-finish components where practical before assembly, especially where later access is restricted.
Ensure risers do not force treads out of level. Any minor discrepancy should be corrected before moving upward through the flight.
Step 9: Install treads
9️⃣ Fix Treads Square, Level and With Controlled Gaps
Cut treads to exact length with consistent overhang or flush detail as shown on the drawings. Dry-lay the first few treads to confirm alignment across all stringers before final fixing.
Apply construction adhesive to each stringer contact point where specified, then fix treads with screws from above, from below, or with concealed methods depending on finish standard.
When fixing treads:
For external stairs, leave suitable drainage gaps if the tread system requires it. For internal feature stairs, maintain tight scribe joints and fill only where permitted by the finish specification.
💡 Pro tip: On exposed hardwood treads, fix with stainless steel screws and matching plugs for a cleaner finish and long-term durability.
Step 10: Check the full flight and complete finishing
🔟 Finalise, Protect and Prepare for Handover
Once all treads and risers are fixed, carry out a complete compliance and quality check:
Sand exposed surfaces as required and apply the specified finish:
Do not hand over until the stair is protected from follow-on trades. Newly installed treads are highly prone to gouging and paint contamination.
Common Mistakes to Avoid
Pro Tips
Recommended Tools
Frequently asked questions
- What Australian standards apply to timber stair stringers and treads?
- Timber stair installation in Australia must comply with National Construction Code (NCC 2022 Volume Two) Part H5D2 and AS 1684 Residential Timber-Framed Construction. Outdoor stairs require preservative-treated timber compliant with AS 1604, specifying a minimum of H3 treatment for exterior above-ground structural framing members and treads.
- How do you calculate rise and going for stairs under NCC 2022?
- Calculate stair dimensions by dividing the total vertical rise by target step heights between 115mm and 190mm to determine riser count. Ensure the going measures between 240mm and 355mm, satisfying the NCC rule where twice the rise plus the going (2R + G) equals 550mm to 700mm across all steps.
- What is the minimum throat depth for a cut timber stair stringer?
- The structural throat depth for cut timber stair stringers must measure at least 90mm of sound, un-notched timber throughout the entire span. For standard residential external decks, carpenters cut 250x50mm or 300x50mm F7 or MGP10 treated pine or hardwood stock to maintain adequate throat thickness beneath internal tread cuts.
- How do you fix timber stair stringers to a deck landing?
- Secure timber stair stringers directly to structural deck joists or bearers using Pryda or Simpson Strong-Tie stringer brackets and M12 hot-dipped galvanised coach screws. Never fasten stringers exclusively to non-structural timber fascia boards; install structural solid blocking behind the landing rim board to handle dynamic descent point loads.
- Why is the bottom of a stair stringer cut down by the tread thickness?
- The bottom plumb cut of a stair stringer must be shortened by the exact thickness of one finished tread. Removing this dimension ensures the first step rise matches all subsequent steps once the tread boards are installed, preventing a dangerous rise variation that violates the 5mm NCC maximum tolerance.
- How do you avoid overcutting notches in timber stair stringers?
- Prevent overcutting stringer throat corners by terminating all circular saw cuts approximately 10mm to 15mm before reaching the pencil line intersection. Complete the internal corner cuts manually using a handsaw or jigsaw to eliminate overcut blade kerfs, which create stress concentrations and cause stringers to crack under load.
Written by Chippy, the Carpentry & Joinery specialist at VIC.Tools.