How to troubleshoot a split system air conditioner that is not heating in winter — Victoria Guide

A split system air conditioner not heating in Victoria's cooler months often points to a simple setup, airflow, or maintenance issue. This guide helps Victorian homeowners safely troubleshoot their reverse-cycle system before needing a licensed professional.

Skill level
Intermediate
Time
30 minutes to 2 hours, depending on cleaning required and whether the fault is a simple settings issue or needs professional diagnosis
Trade
HVAC & Refrigeration
Updated
29 November 2026

Tools you will need

  • Remote control for the split system
  • Fresh AAA/AA batteries for the remote
  • User manual or manufacturer app
  • Step ladder
  • Torch
  • Soft microfibre cloth
  • Vacuum cleaner with soft brush attachment
  • Fin comb or soft brush for accessible coil debris
  • Digital room thermometer
  • Outdoor thermometer or weather app

Why is my split system air conditioner not heating in winter?

A split system air conditioner that is not heating in Victoria's cooler months is often suffering from a simple setup, airflow or maintenance issue rather than a major breakdown. This guide walks Victorian homeowners through safe, practical checks to identify why a reverse-cycle system is blowing cool air, cycling oddly, or struggling to reach temperature before calling in a licensed technician. Understanding these common issues can save you a call-out fee, especially during peak winter demand in Melbourne or regional areas like Ballarat and Bendigo.

What skill level is required to troubleshoot a split system heating issue in Victoria?

Intermediate — Most checks are straightforward for a homeowner, but heating faults can involve electrical components, sensors, refrigerant charge or defrost controls that legally require a licensed electrician and/or ARCtick-licensed refrigeration mechanic in Australia. In Victoria, all electrical work must be carried out by a licensed electrician registered with Energy Safe Victoria (ESV), and refrigerant handling by an ARCtick-licensed technician.

How long does it typically take to troubleshoot a split system that isn't heating?

30 minutes to 2 hours, depending on cleaning required and whether the fault is a simple settings issue or needs professional diagnosis. Be mindful that during a cold snap, professional technicians may have extended wait times.

What tools are essential for troubleshooting a split system heating issue?

Remote control for the split system
Fresh AAA/AA batteries for the remote
User manual or manufacturer app (often available online for brands like Daikin, Mitsubishi Electric, Fujitsu General, Panasonic and ActronAir)
Step ladder (ensure it's stable on uneven ground, especially if working outdoors)
Torch
Soft microfibre cloth
Vacuum cleaner with soft brush attachment
Fin comb or soft brush for accessible coil debris (can be found at hardware stores like Bunnings or Sydney Tools)
Digital room thermometer
Outdoor thermometer or weather app (useful for understanding ambient temperatures, especially in frost-prone areas)
Notepad or phone for recording fault codes
Garden gloves
Bucket and mild detergent for washable filters
Smartphone to photograph model numbers and error displays

How do you troubleshoot a split system air conditioner that is not heating?

1.Confirm the system is actually in HEAT mode — This sounds obvious, but it is the number one winter callback item. On brands such as Daikin, Mitsubishi Electric, Fujitsu General, Panasonic and ActronAir, make sure the remote is set to HEAT (sun icon), not AUTO, DRY or FAN. In AUTO mode, the unit may decide the room is warm enough and blow unheated air or stop the compressor. Set the temperature to 24–26°C for testing, with fan speed on AUTO. Remember, Victoria's 6-star energy efficiency requirements for new builds mean systems are designed to be efficient, so proper mode selection is key.
2.Replace the remote batteries and reset the settings — Weak remote batteries can cause partial commands or stop the indoor unit receiving the mode change properly. Fit new batteries, then turn the system off for 5 minutes and restart it in HEAT mode. If your unit uses Wi-Fi control, check the app and compare settings with the remote to make sure there is no conflict. This is a common issue, especially with smart home integrations.
3.Allow proper warm-up time — Reverse-cycle systems do not always blow warm air immediately. Many indoor units delay the fan for 2 to 10 minutes while the indoor coil heats up, to avoid a cold draft. If the system has just started, wait a full 10–15 minutes before deciding it is not heating. During this time, watch for the outdoor unit starting up and listen for compressor operation. This delay is particularly noticeable on colder Victorian mornings.
4.Check the set temperature against actual room temperature — Use a thermometer in the room, ideally away from direct drafts or sunlight. Ensure the set temperature on your remote is at least 3-5°C higher than the current room temperature. If the room is already warm, the system may not engage heating. This is crucial for systems operating in Victoria's temperate climate where temperatures can fluctuate rapidly.

Frequently asked questions

What is involved in troubleshoot a split system air conditioner that is not heating in winter?
A split system air conditioner that is not heating in winter is often suffering from a simple setup, airflow or maintenance issue rather than a major breakdown. This guide walks Australian homeowners through safe, practical checks to identify why a reverse-cycle system is blowing cool air, cycling o
What skill level do I need for troubleshoot a split system air conditioner that is not heating in winter?
Intermediate — Most checks are straightforward for a homeowner, but heating faults can involve electrical components, sensors, refrigerant charge or defrost controls that legally require a licensed electrician and/or ARCtick-licensed refrigeration mechanic in Australia.
What are common mistakes when troubleshoot a split system air conditioner that is not heating in winter?
Assuming the system is broken when it is actually in defrost mode or still in its normal warm-up delay. Running the unit in AUTO mode in winter and expecting constant heating output. Ignoring dirty filters and then blaming the refrigerant charge. Blocking the indoor unit with curtains, furniture or drying clothes underneath it. Setting the louvres horizontally so all the warm air poo
What tools do I need for troubleshoot a split system air conditioner that is not heating in winter?
This guide includes a comprehensive tools list. Key hvac & refrigeration tools are detailed in the Tools Required section.
What is the Australian standard for electrical safety on split systems?
The Australian standard for electrical safety on split systems is primarily governed by AS/NZS 3000:2018, known as the 'Wiring Rules'. This standard outlines the mandatory requirements for electrical installations, ensuring safety and compliance. Any electrical work on these units must be carried out by a licensed electrician to meet these regulations.
Why is my split system blowing cold air in heat mode?
Your split system might be blowing cold air in heat mode due to several reasons, including incorrect remote settings (e.g., set to AUTO instead of HEAT), dirty filters restricting airflow, or the unit being in defrost mode. It could also indicate low refrigerant charge or a faulty sensor, which requires professional diagnosis.
Can I legally add refrigerant to my split system in Australia?
No, in Australia, it is illegal for an unlicensed individual to handle or add refrigerant to a split system. According to the Australian Refrigeration Council (ARC) and the Ozone Protection and Synthetic Greenhouse Gas Management Act 1989, only ARCtick-licensed technicians are authorised to perform work involving refrigerants due to environmental and safety regulations.
What temperature should I set my split system to for efficient heating?
For efficient heating, it is generally recommended to set your split system to between 20°C and 22°C. According to energy efficiency guidelines, every degree above 20°C can increase energy consumption by up to 10%. Setting the fan speed to AUTO also helps distribute heat effectively without excessive energy use.
Do I need a permit to replace my split system in Victoria?
Generally, replacing an existing split system with a like-for-like unit doesn't require a building permit from the Victorian Building Authority (VBA). However, any new electrical wiring or significant structural changes would require a permit and licensed tradespeople.
What are common issues for split systems in Victoria's winter?
Beyond basic settings, common issues in Victoria include outdoor units freezing up due to cold, damp conditions (requiring defrost cycles), dirty filters reducing airflow, and refrigerant leaks. Regular maintenance helps prevent these, especially in frost-prone areas.

Written by Frosty, the HVAC & Refrigeration specialist at VIC.Tools.