Skip to main content

Guide to Fittings

If you are asking, “What fittings do I need?”, the answer depends on the fixture, the pipe material, the connection size, and whether you are connecting water supply, waste, or both. In Australian plumbing, most tap and fixture connections are based around 15 mm water supplies with 1/2" BSP

Skill level
Intermediate
Time
1–2 hours to identify and specify fittings; 2–6 hours for installation by a licensed plumber
Trade
Plumbing
Updated
28 November 2026

Tools you will need

  • Tape measure with mm markings
  • Adjustable spanners, 200 mm and 250 mm
  • Basin spanner for tight tap backnuts
  • Multi
  • Thread gauge or vernier caliper for checking thread sizes
  • Deburring tool
  • PTFE thread tape suitable for potable water
  • Torch or headlamp for under

🔧 Guide to Plumbing Fittings for Fixtures & Taps

What plumbing fittings are essential for fixtures and taps in Australian homes?

If you are asking, “What fittings do I need?”, the answer depends on the fixture, the pipe material, the connection size, and whether you are connecting water supply, waste, or both. In Australian plumbing, most tap and fixture connections are based around 15 mm water supplies with 1/2" BSP threaded tapware connections, while wastes are commonly 32 mm, 40 mm, or 100 mm depending on the fixture.

Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials. Selection and installation should align with the PCA/NCC Volume Three and AS/NZS 3500 series, with licensing overseen by NSW Fair Trading, VIC VBA, QLD QBCC, and WA Building Commission.

What skill level is required for selecting and installing plumbing fittings in Australia?

Intermediate — Estimated time: 1–2 hours to identify and specify fittings; 2–6 hours for installation by a licensed plumber

What specific tools are required for installing plumbing fittings for fixtures and taps in Australia?

Tape measure with mm markings
Adjustable spanners, 200 mm and 250 mm
Basin spanner for tight tap backnuts
Multi-grip pliers
Thread gauge or vernier caliper for checking thread sizes
Tube cutter suitable for 15 mm copper or PEX cutter for 16 mm PEX
Deburring tool
PTFE thread tape suitable for potable water
Torch or headlamp for under-sink and vanity work
Bucket and towels for residual water during isolation/testing

What materials are required for plumbing fittings for fixtures and taps in Australia?

Isolation stop valves or mini cocks, typically 15 mm x 1/2" BSP
Flexible braided tap connectors, commonly 15 mm x 1/2" BSP or mixer-specific tails
Mixer tap or tap set, matched to fixture mounting holes
Wall flanges and spindle extensions where required
Basin waste, usually 32 mm
Sink or laundry waste, usually 40 mm
Bottle trap or P-trap, typically 32 mm for basins and 40 mm for sinks/laundries
Pan connector for toilet, typically 100 mm
Shower outlet elbow or wall plate elbow, usually 15 mm
Brass cap, plug, nipple, elbow, tee, or reducing fittings as required
Copper tube 15 mm to AS 1432 or PEX pipe 16 mm to relevant Australian product standards
Copper/brass compression or press fittings to suit pipe system
DWV pipe and fittings in 40 mm, 50 mm, or 100 mm to suit waste application
Tap washers, O-rings, olives, seals, and fixing kits
Neutral-cure sanitary silicone
Tempering valve where required for heated water serving sanitary fixtures under AS/NZS 3500.4

Safety Requirements

Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials.
Isolate the water supply before disconnecting any tap, mixer, stop valve, or flexible connector.
Confirm the hot water system delivery temperature is compliant. Bathroom outlets generally require tempered water to a maximum of 50°C under AS/NZS 3500.4 and PCA requirements.
Use only approved fittings suitable for potable water and matched to the pipe system manufacturer’s instructions.
Do not mix incompatible metals without considering corrosion risk.
Check that any backflow protection requirement is met, especially for hose taps, bidet sprays, and specialist fixtures.
Gas work requires a separate gas fitter licence and is not covered by standard plumbing licensing.
Waterproofing around showers and wall penetrations must be coordinated with licensed trades and relevant NCC requirements.

Step-by-Step Guide

Step 1: 1️⃣ Identify the fixture and what it needs to connect to

Start by identifying whether the fitting is for a basin, kitchen sink, laundry tub, shower, bath, toilet, or appliance point.

For each fixture, check three things:

Water supply connection
Waste outlet connection
Mounting/fixing method

In most Australian homes:

Water supplies are commonly 15 mm
Tapware thread connections are commonly 1/2" BSP
Basin wastes are usually 32 mm
Sink and laundry wastes are usually 40 mm
Toilet pan connections are usually 100 mm

If you are only replacing tapware, you may only need isolation valves and flexi connectors. If you are replacing the full fixture, you will usually also need wastes, traps, seals, and fixing hardware.

Step 2: 2️⃣ Match the fitting set to the fixture type

This is the practical answer to “What fittings do I need?”

For a basin mixer you will usually need:

2 x isolation stop valves or mini cocks, 15 mm x 1/2" BSP
Mixer with flexible tails or connectors
Basin waste, 32 mm
Bottle trap or P-trap, usually 32 mm inlet to 40 mm wall connection as required
Backnuts, rubber seals, and silicone where specified by manufacturer

For a kitchen sink mixer you will usually need:

2 x isolation stop valves, 15 mm x 1/2" BSP
Mixer tails/flexi connectors
Basket waste or sink waste set, usually 40 mm
Sink trap, usually 40 mm
Dishwasher branch trap if connecting a dishwasher

For a laundry tub you will usually need:

2 x 15 mm isolation valves
Tap set or mixer
Waste and trap, typically 40 mm
Washing machine cock set if supplying a washer

For a shower mixer and outlet you will usually need:

In-wall mixer body or tap breech
Hot and cold water connections in 15 mm
Wall plate elbow or outlet fitting, usually 15 mm
Shower head/rail set
Cover plate/flanges
Waterproofing-compatible penetrations and sealing collars

For a bath you will usually need:

Bath mixer or tap set
Spout or combination outlet
Bath waste and overflow set, commonly 40 mm
Isolation valves and connection fittings in 15 mm

For a toilet suite you will usually need:

Isolation cock, usually 15 mm
Toilet inlet connector or flexible hose
Pan connector, usually 100 mm
Pan collar or sealing system as specified by manufacturer
Fixing kit and pan seal

For an appliance point such as dishwasher or fridge:

Appliance isolation valve
Dual outlet mini cock if sharing a basin/sink supply
Pressure-limiting or check valve only if specified by manufacturer or local requirements

Step 3: 3️⃣ Confirm connection sizes, thread types, and pipe material

Do not assume every fitting is interchangeable. Check:

Pipe material: copper, PEX, stainless braided connection, PVC DWV
Connection type: compression, crimp, press-fit, threaded, push-fit
Thread standard: commonly 1/2" BSP for domestic tapware
Set-out and spacing for mixers or wall tap sets

Typical Australian domestic supply pipe sizes are:

15 mm for basin, sink, toilet, shower, and bath branches
20 mm for higher-demand or grouped supplies in some installations

Typical waste sizes are:

32 mm for basin waste
40 mm for kitchen sink, bath, and laundry waste
50 mm for some floor wastes or branch drains
100 mm for toilet discharge

If you are connecting to copper, use fittings compatible with copper tube to AS 1432.

If you are connecting to PEX, use the manufacturer’s matched crimp/press/sliding sleeve system and do not cross-brand unless expressly approved.

Step 4: 4️⃣ Check compliance items before buying fittings

Good fitting selection is not just about “will it screw on?” It must also comply with Australian requirements.

Check:

WELS rating of taps and shower heads
Pressure rating of the tapware and flexible connectors
Tempering requirements for hot water to bathrooms
Backflow protection for hose taps, health fixtures, or specialty outlets
Whether the fixture manufacturer requires pressure-limiting valves, check valves, or proprietary connectors

As a guide:

Basin and sink mixers with 4 Star to 6 Star WELS ratings are common efficient choices
Shower heads with 3 Star to 4 Star WELS ratings are common water-saving options
Flexible hoses should be WaterMark-certified and suitable for concealed or exposed use only as allowed by manufacturer instructions

Selection and installation should comply with AS/NZS 3500.1, AS/NZS 3500.2, and AS/NZS 3500.4 where applicable.

Step 5: 5️⃣ Select the waste, trap, and sealing components

A very common mistake is buying the tap fittings but forgetting the waste and trap components.

For most fixture replacements:

A basin needs a 32 mm waste and matching trap
A sink needs a 40 mm basket waste and trap
A laundry tub typically uses 40 mm waste and trap
A bath usually needs a 40 mm waste/overflow set
A toilet needs a 100 mm pan connector suited to S-trap or P-trap configuration

Also check:

Wall outlet position
Trap orientation
Whether space under the fixture requires a bottle trap instead of a standard P-trap
Whether the outlet needs a dishwasher branch or overflow connection

Use only seals and washers supplied or approved by the fitting manufacturer. Overuse of silicone or thread tape in the wrong place often causes leaks rather than preventing them.

Step 6: 6️⃣ Plan installation and testing with a licensed plumber

Once the fittings are selected, installation should be completed by a licensed plumber.

The installation process generally involves:

Isolating water
Removing old tapware/fixture
Inspecting stop taps and pipe condition
Installing new valves, connectors, tapware, waste, and trap
Reinstating water supply
Pressure and leak testing
Checking fixture operation, drainage fall, and temperature compliance

A licensed plumber will also confirm:

WaterMark approval
Correct support and clip spacing
No cross-threading or overtightening
Compliance certificates or notices where required by your state or territory

Common Mistakes to Avoid

1.Buying fittings based only on appearance and not checking thread size, set-out, or pipe material.
2.Assuming all tap connectors are the same. Many mixers use proprietary tail lengths and fixing kits.
3.Forgetting the waste and trap. A new basin or sink often needs a new 32 mm or 40 mm waste assembly to suit.
4.Mixing incompatible systems, such as using the wrong crimp/press fittings for the pipe brand or system.
5.Installing bathroom tapware without checking hot water tempering, WELS compliance, and WaterMark approval.

Pro Tips

💡 Take photos of the existing valves, pipework, wastes, and under-bench space before buying fittings. This saves multiple trips to the supplier.
💡 Replace old isolation valves when changing tapware. It is cheap insurance and makes future servicing much easier.
💡 For kitchen sinks, choose a trap with a dishwasher branch if there is any chance an appliance will be added later.
💡 Aim for good WELS ratings: 4 Star to 6 Star taps and 3 Star to 4 Star showers are strong water-saving choices without compromising usability.
💡 If space under a vanity is tight, check whether a bottle trap provides better clearance than a standard P-trap.

Recommended Tools

Basin Spanner — essential for removing and tightening tap backnuts in tight vanity and sink spaces
Knipex Cobra Multi-Grips — reliable grip for valves, traps, and compression fittings
Rothenberger Tube Cutter 15 mm–22 mm — clean cuts on copper tube
Vernier Caliper — useful for accurately checking pipe OD and fitting/thread dimensions
PTFE Thread Tape for Potable Water — suitable for approved threaded plumbing joints where required

Frequently asked questions

What fittings do I need?
If you are asking, “What fittings do I need?”, the answer depends on the fixture, the pipe material, the connection size, and whether you are connecting water supply, waste, or both. In Australian plumbing, most tap and fixture connections are based around 15 mm water supplies with 1/2" BSP
What skill level is needed for guide to fittings?
Intermediate — Estimated time: 1–2 hours to identify and specify fittings; 2–6 hours for installation by a licensed plumber
What are common mistakes when guide to fittings?
1. Buying fittings based only on appearance and not checking thread size, set-out, or pipe material. 2. Assuming all tap connectors are the same. Many mixers use proprietary tail lengths and fixing kits. 3. Forgetting the waste and trap. A new basin or sink often needs a new 32 mm or 40 mm waste assembly to suit. 4. Mixing incompatible systems, such as using the wrong crimp/press fittin
What tools do I need for guide to fittings?
This guide includes a comprehensive tools list. Key plumbing tools are detailed in the Tools Required section.
What Australian Standards apply to plumbing fittings?
The primary Australian Standards for plumbing fittings are the AS/NZS 3500 series, particularly AS/NZS 3500.1:2021 for water services and AS/NZS 3500.2:2021 for sanitary plumbing and drainage. These standards, referenced by the National Construction Code (NCC) Volume Three, dictate material suitability, installation practices, and performance requirements for all plumbing work in Australia.
What is the Australian standard for plumbing installations?
The primary Australian standard for plumbing installations is the AS/NZS 3500 series, which covers water services, sanitary plumbing, stormwater, and heated water. This series is referenced by the Plumbing Code of Australia (PCA) within the National Construction Code (NCC) Volume Three, ensuring uniform compliance across all states and territories.
Why is a licensed plumber required for fittings installation in Australia?
A licensed plumber is required for fittings installation in Australia to ensure compliance with health, safety, and environmental regulations, as well as the AS/NZS 3500 standards. Unlicensed work can void insurance, lead to fines, and pose significant risks of water damage or contamination, as mandated by state regulatory bodies like NSW Fair Trading.
What are common mistakes when selecting plumbing fittings?
Common mistakes include not verifying thread sizes (e.g., 1/2" BSP vs. 3/4" BSP), overlooking specific set-out dimensions for mixer taps, and failing to account for waste and trap requirements (e.g., 32 mm or 40 mm). Additionally, mixing incompatible pipe materials or connection systems (e.g., crimp vs. compression) can lead to leaks and system failure.
How do you correctly measure pipe and fitting sizes?
To correctly measure pipe and fitting sizes, use a thread gauge or vernier caliper to determine the nominal bore and thread type (e.g., BSP). For pipes, measure the outside diameter (OD) for copper or PEX, and the inside diameter (ID) for some PVC applications. Always refer to manufacturer specifications and AS/NZS 3500 guidelines for accurate sizing.

Written by Pipey, the Plumbing specialist at VIC.Tools.