Skip to main content

How to clear a blocked stormwater drain

Clearing a blocked stormwater drain is a high-urgency drainage task that requires fast fault-finding, safe access, and the correct use of augers, high-pressure jetters, and CCTV inspection equipment. The objective is not just to restore flow, but to identify whether the blockage is caused by debris,

Skill level
Advanced
Time
1-6 hours for clearing and inspection, longer if excavation or pipe repair is required
Trade
Plumbing
Updated
28 November 2026

Tools you will need

  • CCTV drain camera with self
  • High
  • Sectional auger or drum machine with cutters sized for 90
  • Hose for controlled flushing and final flow testing

🔧 How to Clear a Blocked Stormwater Drain — Australian Trade Guide

What is involved in clearing a blocked stormwater drain?

Clearing a blocked stormwater drain is a high-urgency drainage task that requires fast fault-finding, safe access, and the correct use of augers, high-pressure jetters, and CCTV inspection equipment. The objective is not just to restore flow, but to identify whether the blockage is caused by debris, silt, roots, a belly, a broken section, or an outlet restriction at the legal point of discharge.

Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials. Works should be carried out in accordance with the PCA (NCC Volume Three) and relevant provisions of AS/NZS 3500.3 for stormwater drainage.

What skill level is required to clear a blocked stormwater drain?

Advanced — Estimated time: 1-6 hours for clearing and inspection, longer if excavation or pipe repair is required

What tools are required to clear a blocked stormwater drain?

CCTV drain camera with self-levelling head and 512 Hz sonde, suitable for 90 mm, 100 mm, and 150 mm stormwater lines
High-pressure drain jetter with stormwater hose reel, foot control, and nozzle set including penetrator, flusher, and root-cutting heads
Sectional auger or drum machine with cutters sized for 90-150 mm lines
Drain rods with retrieval, corkscrew, and plunger heads for short runs and pit-to-pit work
Pipe locator/receiver for tracing line and defect depth from CCTV sonde
Pit key, pry bar, shovel, spade, trenching shovel, and debris scoop
Wet vacuum or sludge pump for dewatering pits and removing silt
Hand tools including multigrips, screwdrivers, adjustable spanner, hammer, cold chisel, and tape measure
Hose for controlled flushing and final flow testing
Barricades, cones, warning tape, and temporary traffic/pedestrian control equipment where required
PPE: waterproof gloves, gumboots, eye protection, hearing protection, high-vis clothing, rain gear, and P2 respirator where contaminated silt or mould is present

Materials Required

Replacement PVC-U stormwater pipe in 90 mm, 100 mm, or 150 mm to AS/NZS 1254, or DWV pipe to AS/NZS 1260 where matching existing installation
PVC stormwater fittings to suit: bends, couplings, inspection openings, adaptors, caps, and junctions
Rubber repair couplings/shear bands to suit pipe OD for point repairs
PVC primer and solvent cement compatible with the pipe and fitting system
Replacement pit risers, pit baskets, sediment buckets, grates, or grated drains as required
Crushed drainage aggregate, bedding sand, and compactable backfill for reinstatement
Geotextile fabric or silt socks where sediment control is required during wet-weather works
Root barrier material if tree-root recurrence is being addressed during excavation
Marker paint and defect tags for locating and reporting damaged sections

Safety Requirements

Treat all stormwater overflows as slip, contamination, and property-damage hazards; isolate the work area before opening pits or removing grates.
Never place hands into a charged stormwater line or pit until flow conditions are confirmed and visible debris is removed safely.
High-pressure jetting can cause injection injuries and whipping hose incidents; use foot control, correct nozzle retention, and manufacturer pressure limits at all times.
Use hearing and eye protection when operating jetters, augers, or cutting heads.
Avoid energised electrical hazards during storms, especially near submersible pumps, outdoor GPOs, garden lighting, and flooded plant areas.
Do not enter pits, manholes, tanks, or any confined space without a compliant confined space system, permit, atmospheric testing, rescue plan, and trained personnel.
If excavation is required, comply with trench safety, underground service locating, and shoring/battering requirements.
Use traffic and pedestrian management where pits are in driveways, footpaths, laneways, or road reserves.
Confirm the system is stormwater, not sanitary drainage; cross-connections and mixed systems require further investigation and may trigger additional compliance requirements.
Stormwater clearing and repairs must align with the PCA and AS/NZS 3500.3. Any repair to sanitary drainage may also involve AS/NZS 3500.2 requirements.
🔒 Licensing: Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials. Licensing requirements are administered by authorities such as NSW Fair Trading, VIC VBA, QLD QBCC, and the WA Building Commission. Gas work is not part of stormwater drainage and requires a separate licensed gas fitter where any associated gas services are involved on site.

Step-by-Step Guide

Step 1: 1️⃣ Make the site safe and confirm the overflow source

Attend the site and identify immediate risks to occupants, structures, and accessways. During storm conditions, first control surface water where possible to reduce further ingress into garages, subfloors, plant rooms, or habitable areas.

Confirm the reported issue is stormwater surcharge and not a sewer overflow. Check whether water is backing up from grated drains, pit lids, strip drains, downpipes, ag lines discharging into pits, or the legal point of discharge.

Set up barricades around flooded pits, slippery surfaces, and open grates. If there is any risk of water contacting electrical equipment, isolate power through the appropriate channels before commencing work.

Step 2: 2️⃣ Identify the system layout and likely blockage zone

Establish the stormwater line path from upstream collection points to the legal point of discharge. Review site plans if available and locate all downpipes, pits, inspection openings, charged lines, rainwater tank overflows, and discharge points to kerb, inter-allotment drainage, easement line, or on-site detention system.

Open the lowest accessible pit first. If that pit is full, move downstream toward the outlet. If it is clear, move upstream until you find the first pit with standing water. The blockage is typically between the last clear point and the first surcharged point.

Where layout is unclear, use the CCTV sonde and locator, or trace visible pipe alignments and surface depressions. In older sites, allow for undocumented alterations, broken junctions, and illegal tie-ins.

Step 3: 3️⃣ Open and clean access points

Remove pit lids, grates, leaf guards, and inspection caps carefully. Clear loose debris by hand tools, scoop, or vacuum before introducing rods or jetting equipment.

If pits are silted, vacuum or shovel out accumulated sediment so you can see inlet and outlet invert levels. This is critical for distinguishing a line blockage from a silted pit, a downstream surcharge, or a failed outlet.

Check for obvious restrictions such as:

leaf matter and mulch at grated drains
roof tile fragments from downpipes
concrete washout or render slurry
root masses at joints
collapsed grates or crushed risers
sediment plugging the outlet pipe within the pit wall

Step 4: 4️⃣ Establish a pilot opening with rods or auger

For short runs or soft blockages, rod the line from the downstream side toward the obstruction. For heavier debris, roots, or compacted silt, use a sectional auger or drum machine sized for the pipe diameter.

Use the least aggressive head first to avoid damaging older PVC, thin-wall pipe, corrugated pipe, or brittle earthenware sections. A pilot hole through the blockage allows initial relief and improves jetter effectiveness.

If the tool repeatedly hangs at the same distance, suspect:

root ingress at a joint
a displaced junction
a backfall holding silt
a collapsed or deformed section
a foreign object wedged at a bend or junction

Do not force the machine if pipe failure is likely. Escalate to CCTV inspection if resistance is abnormal or the pipe material is unknown.

Step 5: 5️⃣ Jet the line correctly from the downstream access

Set up the jetter at the most suitable downstream access point so debris can be drawn back or flushed toward a controlled discharge location. For most blocked stormwater lines, work upstream from the downstream pit to break and mobilise debris, then perform a final downstream flush to the outlet.

Select the nozzle to suit the obstruction:

penetrator nozzle for total blockage
flusher nozzle for silt, leaves, and sludge
root-cutting nozzle only where pipe condition and material are suitable
spinning rear jet for wall cleaning after initial opening

Advance the hose steadily, not aggressively. Let the nozzle work rather than forcing it. Withdraw in controlled passes to bring debris back to the pit for removal. Repeat until the line runs free and the return water is substantially cleaner.

For charged or surcharged systems, monitor upstream pits while jetting. If water levels rise suddenly, stop and reassess to avoid property flooding or hose entrapment.

Step 6: 6️⃣ CCTV inspect the full run after flow is restored

Once the line is open, perform a CCTV inspection from upstream to downstream or vice versa depending on access and line condition. Record the full run, note defect positions by metre count, and locate defects from the surface using the sonde.

Typical stormwater defects include:

root ingress through couplings or cracked sockets
settled sections holding silt
backfall or inadequate grade
broken junctions
displaced rubber ring joints
crushed or ovalised pipe
concrete slurry or building debris left from construction
outlet restrictions at kerb adaptors or silted charged lines

A clear-flowing line can still be non-compliant or structurally defective. CCTV is the step that separates temporary relief from a proper diagnosis.

Step 7: 7️⃣ Repair or recommend rectification of the underlying defect

If CCTV shows a structural failure, point repair or replacement is generally required. Mark out the defect location, verify underground services, and excavate only after confirming depth and alignment.

Typical rectification works include:

replacing broken PVC sections in 90 mm, 100 mm, or 150 mm
cutting out root-affected joints and installing new couplings
regrading a sagged section to remove a silt trap
replacing a damaged pit base, riser, or grate
clearing and rebuilding the legal point of discharge
separating illegal stormwater connections or cross-connections
installing additional inspection openings for future maintenance access

Use compatible materials and fittings, and match the existing system standard where practicable. Reinstate bedding and backfill properly to avoid repeat settlement.

Step 8: 8️⃣ Flush, test, reinstate, and document the job

Run a controlled hose or water test from the highest upstream inlet or downpipe. Confirm the line drains freely through each pit and discharges correctly at the legal point of discharge without backing up.

Remove all debris from pits and site surfaces. Refit grates, lids, leaf guards, and caps securely. Reinstate landscaping, paving, or soft ground where disturbed.

Document:

blockage cause
clearance method used
CCTV findings
defect locations and depths
repairs completed
outstanding recommendations
before/after photos or footage

For strata, commercial, or insurance-related work, provide a concise report identifying whether the issue was maintenance, storm loading, or asset failure.

Common Mistakes to Avoid

1.Starting with aggressive root cutting or heavy augering before confirming pipe material and condition, resulting in avoidable pipe damage.
2.Clearing the blockage without CCTV inspection, then missing a broken section, belly, or displaced joint that causes the line to block again.
3.Jetting from the wrong access point and pushing debris further into the system instead of retrieving or flushing it in a controlled direction.
4.Failing to clean pits before diagnosis, which can make a silted pit look like a blocked line and lead to misdiagnosis.
5.Treating the symptom only and not checking the legal point of discharge, where many stormwater issues are caused by blocked kerb outlets, inter-allotment lines, or downstream surcharge.

Pro Tips

💡 Start at the downstream end whenever possible. The quickest diagnosis usually comes from identifying the first full pit and the last clear pit.
💡 In wet season callouts, carry both a jetter and CCTV as standard. Clearing without recording the defect often creates a repeat emergency within the next major rain event.
💡 When silt is the main issue, higher flow and the correct flushing nozzle are usually more effective than chasing maximum pressure.
💡 If roots are present, inspect all nearby junctions and couplings. A single root ball often indicates multiple compromised joints in the same run.
💡 Where repeated leaf and mulch blockages occur, recommend pit baskets, improved grate maintenance, and better surface debris control rather than repeated reactive clearing.

Recommended Tools

Ridgid SeeSnake Compact C40 with locator — reliable CCTV inspection and sonde locating for residential and light commercial stormwater lines
Ridgid K-6200 sectional machine — strong option for initial mechanical opening and root intrusion work in 90-150 mm drains
Jetwave or Aussie Pumps trailer/portable jetter — suitable for trade stormwater clearing with interchangeable nozzles and long hose reach
Radiodetection locator — accurate sonde tracing and defect depth confirmation before excavation
Nilfisk or similar wet vacuum/sludge extractor — fast pit cleaning and silt removal before jetting or camera work

Frequently asked questions

What is involved in clear a blocked stormwater drain?
Clearing a blocked stormwater drain is a high-urgency drainage task that requires fast fault-finding, safe access, and the correct use of augers, high-pressure jetters, and CCTV inspection equipment. The objective is not just to restore flow, but to identify whether the blockage is caused by debris,
What skill level do I need for clear a blocked stormwater drain?
Advanced — Estimated time: 1-6 hours for clearing and inspection, longer if excavation or pipe repair is required
What are common mistakes when clear a blocked stormwater drain?
1. Starting with aggressive root cutting or heavy augering before confirming pipe material and condition, resulting in avoidable pipe damage. 2. Clearing the blockage without CCTV inspection, then missing a broken section, belly, or displaced joint that causes the line to block again. 3. Jetting from the wrong access point and pushing debris further into the system instead of retrieving or flush
What tools do I need for clear a blocked stormwater drain?
This guide includes a comprehensive tools list. Key plumbing tools are detailed in the Tools Required section.
What is the Australian standard for stormwater drainage?
The Australian standard for stormwater drainage is AS/NZS 3500.3:2021, 'Plumbing and drainage - Stormwater drainage'. This standard outlines requirements for design, installation, and materials to ensure effective and safe stormwater management. For tradies in Queensland, additional requirements are specified by the Queensland Plumbing and Wastewater Code.
Do I need a license to clear a blocked stormwater drain in Australia?
Yes, in Australia, clearing a blocked stormwater drain that involves working on permanent plumbing infrastructure requires a licensed plumber. According to state and territory plumbing regulations, unlicensed work can result in fines and void insurance. Always verify local licensing requirements before undertaking such work.
What PPE is recommended for clearing blocked stormwater drains?
Recommended PPE for clearing blocked stormwater drains includes waterproof gloves, gumboots, eye protection, hearing protection, high-visibility clothing, and rain gear. According to SafeWork Australia guidelines, a P2 respirator may also be necessary if dealing with contaminated silt or sewage, to protect against airborne hazards.

Written by Pipey, the Plumbing specialist at VIC.Tools.