Skip to main content

How to install a hot water tempering valve

This guide details the compliant installation of a tempering valve on a hot water system in Australia. Tempering valves are crucial for preventing scalding injuries by limiting the maximum hot water delivery temperature to sanitary fixtures, as mandated by the Plumbing Code of Australia (PCA) and AS

Skill level
Intermediate
Time
1-2 hours
Trade
Plumbing
Updated
28 November 2026

Tools you will need

  • Pipe Cutter: For 15mm or 20mm copper or PEX pipe.
  • Adjustable Spanners
  • Crimping Tool
  • Deburring Tool: For copper pipe.
  • Measuring Tape: For accurate pipe cutting.
  • Marker Pen: For marking cut lines.
  • Bucket/Towels: For catching residual water.
  • Thermometer
  • Safety Glasses: Eye protection.
  • Work Gloves: Hand protection.

Why is a hot water tempering valve installation necessary in Australia?

This guide details the compliant installation of a tempering valve on a hot water system in Australia. Tempering valves are crucial for preventing scalding injuries by limiting the maximum hot water delivery temperature to sanitary fixtures, as mandated by the Plumbing Code of Australia (PCA) and AS/NZS 3500.4. This process involves isolating the hot water supply, cutting into the hot water line, installing the valve, and testing its operation.

What skill level is required to install a hot water tempering valve?

Intermediate — Estimated time: 1-2 hours

What specific tools are required for tempering valve installation?

Pipe Cutter: For 15mm or 20mm copper or PEX pipe. Adjustable Spanners (2): For tightening tempering valve connections. Crimping Tool (PEX) / Press Tool (Copper) / Soldering Torch (Copper): Depending on pipe material and connection type. Deburring Tool: For copper pipe. Measuring Tape: For accurate pipe cutting. Marker Pen: For marking cut lines. Bucket/Towels: For catching residual water. Thermometer (Digital or Probe): Essential for checking tempered water temperature. Safety Glasses: Eye protection. Work Gloves: Hand protection.

What materials are needed for a compliant tempering valve installation?

Tempering Valve: AS 4032.2 compliant, appropriate size (15mm or 20mm) for the hot water system. Ensure it's suitable for the water heater type (e.g., solar, storage). Pipe Fittings: Copper: 15mm or 20mm copper pipe, 15mm or 20mm elbows, 15mm or 20mm tees (if cold water connection is needed at the valve). PEX: 15mm or 20mm PEX pipe, crimp/press fittings (elbows, tees, straight connectors). Flexible Hoses: If connecting to the tempering valve directly from the hot water outlet, ensure they are rated for hot water and pressure. Thread Seal Tape (PTFE): For threaded connections. Pipe Dope (Optional): For threaded connections. Insulation: For hot water pipes, including around the tempering valve.

Safety Requirements

⚠️ ALWAYS turn off the main water supply before commencing work. ⚠️ ALWAYS turn off the power/gas supply to the hot water system. ⚠️ BE AWARE of residual hot water in the system; wear appropriate PPE. ⚠️ ENSURE adequate ventilation if soldering. ⚠️ NEVER attempt gas work unless you hold a separate, valid gas fitter's licence. 🔒 Licensing: Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials. Refer to state licensing bodies (e.g., NSW Fair Trading, VIC VBA, QLD QBCC, WA Building Commission) for specific requirements.

Step-by-Step Guide

Step 1: 1️⃣ Isolate Hot Water System

Turn off the main water supply to the property at the main stopcock. Locate the hot water system and turn off its power supply (for electric units at the switchboard) or gas supply (for gas units at the gas meter or appliance valve). Open a hot tap at the highest point in the house and the lowest point (e.g., laundry trough) to drain down the hot water system and relieve pressure. Place a bucket under the hot water system's outlet pipe to catch any remaining water.

Step 2: 2️⃣ Select Tempering Valve Location

The tempering valve must be installed on the hot water outlet pipe as close as practicable to the hot water heater, but after any dedicated hot water outlets that do not require tempering (e.g., dishwasher, washing machine, or solar hot water booster). Ensure there is sufficient space for installation and future maintenance. The valve should be accessible.

Step 3: 3️⃣ Cut and Prepare Hot Water Pipe

Using the pipe cutter, carefully cut a section out of the hot water outlet pipe where the tempering valve will be installed. The length to be removed will depend on the tempering valve's dimensions and the required pipework. Deburr the cut ends of copper pipe. Ensure the cut is clean and straight.

Step 4: 4️⃣ Install Tempering Valve

The tempering valve has three ports: hot water inlet (from heater), cold water inlet (for tempering), and tempered water outlet (to fixtures).

Connect Hot Water Inlet: Connect the hot water pipe from the heater to the 'Hot' inlet port of the tempering valve. Connect Cold Water Inlet: Run a 15mm cold water line from a nearby cold water supply to the 'Cold' inlet port of the tempering valve. This connection must be after the main stopcock and before any other cold water outlets that could affect flow to the tempering valve. Connect Tempered Water Outlet: Connect the tempered water outlet port of the valve to the hot water distribution pipework leading to the sanitary fixtures.

Use appropriate fittings (press, crimp, or solder) for your pipe material. Apply PTFE tape to all threaded connections, ensuring it's wrapped in the direction of the thread. Tighten connections firmly with adjustable spanners, but do not overtighten.

Step 5: 5️⃣ Restore Water and Power/Gas

Once all connections are secure, slowly open the main water supply. Check all new connections for leaks. Once confirmed leak-free, open a hot tap inside the house to purge air from the system. Once water flows freely, turn on the power/gas supply to the hot water system. Allow the system to heat up fully.

Step 6: 6️⃣ Adjust and Test Tempering Valve

Once the hot water system has reached its operating temperature, open a hot tap at a fixture (e.g., basin or shower) and allow the water to run for at least 30 seconds. Using a thermometer, measure the temperature of the water at the tap.

AS/NZS 3500.4 requires: Maximum 50°C for sanitary fixtures (showers, baths, basins). Maximum 45°C for early childhood centres, primary schools, and facilities for the aged, sick, or disabled.

Adjust the tempering valve's setting screw (usually a hex key or screwdriver adjustment) until the desired temperature is achieved. Turn clockwise to decrease temperature, anti-clockwise to increase. Re-test the temperature after each adjustment until compliant.

Step 7: 7️⃣ Insulate Pipework

Insulate all hot water pipework, including the tempering valve, to minimise heat loss and improve energy efficiency. This is a PCA requirement for hot water pipes.

Common Mistakes to Avoid

1.Incorrect Valve Orientation: Installing the tempering valve backwards or with incorrect inlet/outlet connections. Always refer to the manufacturer's instructions and the arrows on the valve body.
2.No Cold Water Supply: Forgetting to connect a dedicated cold water supply to the tempering valve, which is essential for its operation.
3.Inadequate Temperature Testing: Not properly testing and adjusting the tempered water temperature, leading to non-compliance and potential scalding risk. A reliable thermometer is crucial.
4.Overtightening Connections: Stripping threads or damaging fittings by applying excessive force when tightening.
5.Installing After Untempered Outlets: Placing the tempering valve downstream of fixtures that require untempered hot water (e.g., dishwasher), which can lead to issues with appliance performance.

Pro Tips

💡 Pre-assemble: If space is tight, pre-assemble the tempering valve with short lengths of pipe and fittings on a workbench before installing it into the main pipe run. 💡 Isolation Valves: Consider installing isolation valves on the hot and cold inlets to the tempering valve for easier future maintenance or replacement without draining the entire system. 💡 WELS Rating: While tempering valves don't have a WELS rating, ensuring the overall hot water system is efficient (e.g., heat pump, solar) contributes to water and energy savings. 💡 Manufacturer's Instructions: Always keep the manufacturer's installation and adjustment instructions for the specific tempering valve model. 💡 Annual Checks: Advise clients that tempering valves should be checked annually by a licensed plumber to ensure they are operating correctly and maintaining the set temperature.

Recommended Tools

Rothenberger ROCUT 42 Pipe Cutter: For clean, burr-free cuts on plastic pipes up to 42mm. Ridgid Model 151 Quick-Acting Tubing Cutter: Excellent for precise, fast cuts on copper pipe up to 42mm. Milwaukee M18 FORCE LOGIC Press Tool: For efficient and reliable press-fit connections on copper or PEX, significantly reducing installation time.
Fluke 59 MAX Infrared Thermometer: For quick and accurate non-contact temperature measurement of water at the tap.

Frequently asked questions

What is involved in install a hot water tempering valve?
This guide details the compliant installation of a tempering valve on a hot water system in Australia. Tempering valves are crucial for preventing scalding injuries by limiting the maximum hot water delivery temperature to sanitary fixtures, as mandated by the Plumbing Code of Australia (PCA) and AS
What skill level do I need for install a hot water tempering valve?
Intermediate — Estimated time: 1-2 hours
What are common mistakes when install a hot water tempering valve?
1. Incorrect Valve Orientation: Installing the tempering valve backwards or with incorrect inlet/outlet connections. Always refer to the manufacturer's instructions and the arrows on the valve body. 2. No Cold Water Supply: Forgetting to connect a dedicated cold water supply to the tempering valve, which is essential for its operation. 3. Inadequate Temperature Testing: Not properly
What tools do I need for install a hot water tempering valve?
This guide includes a comprehensive tools list. Key plumbing tools are detailed in the Tools Required section.
What is the Australian standard for hot water tempering valves?
The Australian standard for hot water tempering valves is primarily AS/NZS 3500.4:2021, which covers plumbing and drainage, specifically heated water services. This standard, referenced by the Plumbing Code of Australia, mandates that hot water delivered to sanitary fixtures must not exceed 50°C to prevent scalding injuries.
How often should a tempering valve be checked or replaced?
According to AS/NZS 3500.4:2021, tempering valves should be inspected and tested annually by a licensed plumber to ensure correct operation and temperature output. Manufacturers typically recommend replacement every 5-7 years, or sooner if testing reveals inconsistent temperature control or valve failure.
Can I install a tempering valve myself in Australia?
No, in Australia, the installation or replacement of a tempering valve is considered plumbing work and must be carried out by a licensed plumber. This is mandated by state and territory plumbing regulations to ensure compliance with AS/NZS 3500.4 and the Plumbing Code of Australia, preventing potential safety hazards and ensuring warranty validity.
What is the difference between a tempering valve and a thermostatic mixing valve (TMV)?
A tempering valve blends hot and cold water to deliver water at a set maximum temperature, typically 50°C for domestic use, as per AS/NZS 3500.4. A Thermostatic Mixing Valve (TMV) offers more precise temperature control, often used in healthcare or aged care facilities, and is regulated by AS 4032.1.

Written by Pipey, the Plumbing specialist at VIC.Tools.