Skip to main content

How to Install a Rainwater Tank for Home Use

This guide details the process of installing a rainwater tank system for home use, focusing on collecting water from a roof and connecting it for garden irrigation or toilet flushing. It covers site selection, foundation preparation, tank installation, and connecting the necessary plumbing component

Skill level
Intermediate
Time
1-2 days (excluding concrete curing time)
Trade
Plumbing
Updated
29 November 2026

Tools you will need

  • Tape Measure: 8m retractable, steel blade.
  • Spirit Level: 600mm and 1200mm, box
  • Wheelbarrow: 80L capacity.
  • Rubber Mallet: For seating tank.
  • Drill: Cordless 18V impact drill with various drill bits
  • Adjustable Wrench/Spanner Set: For tightening fittings.
  • Caulking Gun: For applying silicone sealant.
  • Safety Knife: Retractable blade.
  • Marker Pen: Permanent, fine tip.
  • Bucket: 10L for mixing.

Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials.

What is involved in installing a rainwater tank for home use in Australia?

This guide details the process of installing a rainwater tank system for home use, focusing on collecting water from a roof and connecting it for garden irrigation or toilet flushing. It covers site selection, foundation preparation, tank installation, and connecting the necessary plumbing components, ensuring compliance with Australian standards for water conservation and safety.

What skill level is required for rainwater tank installation in Australia?

Intermediate — Estimated time: 1-2 days (excluding concrete curing time)

What specific tools are required for rainwater tank installation in Australia?

Tape Measure: 8m retractable, steel blade. Spirit Level: 600mm and 1200mm, box-beam type. Shovel & Spade: Round point and square mouth for excavation. Wheelbarrow: 80L capacity. Trowel & Float: Steel finishing trowel and magnesium float for concrete. Rubber Mallet: For seating tank. Hacksaw or PVC Pipe Cutter: For cutting PVC pipes up to 100mm. Drill: Cordless 18V impact drill with various drill bits (e.g., 10mm masonry, 25mm hole saw for tank connections). Adjustable Wrench/Spanner Set: For tightening fittings. Caulking Gun: For applying silicone sealant. Safety Knife: Retractable blade. Marker Pen: Permanent, fine tip. Bucket: 10L for mixing. Gloves: Heavy-duty work gloves. Safety Glasses: AS/NZS 1337.1 compliant.

What materials are needed for a compliant rainwater tank system in Australia?

Rainwater Tank: Polyethylene or steel, suitable capacity (e.g., 2,000L - 5,000L). Ensure it's certified to AS/NZS 4766 (Polyethylene) or AS/NZS 4020 (Steel). Tank Base Material: Concrete Slab: Cement (20kg bags), aggregate (20mm), sand (washed river sand). Reinforcing mesh (SL72 or similar). Damp-proof membrane (200 micron builders plastic). Formwork timber (70x35mm treated pine). Crushed Rock Base: Crushed rock/road base (e.g., DGB20), geotextile fabric. Tank Inlet Kit: Includes leaf filter/strainer (e.g., 400 micron mesh). First Flush Diverter: 90mm or 100mm PVC, appropriate length for roof area. Overflow Kit: 90mm or 100mm PVC pipe and fittings (elbows, adaptors). Tank Outlet Fittings: Brass tank outlet (e.g., 25mm or 32mm BSP), ball valve (matching outlet size), thread tape (PTFE). Pump (Optional): Automatic pressure pump, suitable for rainwater, with pre-filter. Ensure it's rated for outdoor use if exposed. Pump Cover (Optional): To protect pump from elements. Pipework: Downpipe Adaptors: To connect existing downpipes to first flush diverter/tank inlet (e.g., 90mm round to 100x50mm rectangular). PVC Pipe: 90mm or 100mm Class 6 or 9 (for stormwater/drainage). Pressure Pipe (if connecting to pump): 25mm or 32mm PN12 or PN16 poly pipe (HDPE) or copper pipe. PVC Cement: Medium duty, AS/NZS 3879 compliant. Primer: For PVC cement. Flexible Hose: Reinforced, UV stabilised (e.g., 25mm or 32mm) for pump connection. Stainless Steel Hose Clamps: To secure flexible hose. Silicone Sealant: Neutral cure, suitable for potable water if tank water is for drinking (e.g., AS/NZS 4020 compliant). Fasteners: Screws for downpipe adaptors, formwork nails.

Safety Requirements

ALWAYS wear appropriate Personal Protective Equipment (PPE) including safety glasses, gloves, and sturdy footwear. NEVER work on a roof without proper fall protection. If working at height, use a stable ladder or scaffolding. BE AWARE of underground services (water, gas, electricity) before digging. Dial Before You Dig (1100) is mandatory. EXERCISE CAUTION when lifting heavy objects like tanks or bags of cement. Use correct lifting techniques or mechanical aids. ENSURE electrical connections for pumps are performed by a licensed electrician. GAS WORK requires a separate gas fitter licence. This guide does not cover gas connections. PLUMBING WORK in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials. Refer to your state's licensing body (e.g., NSW Fair Trading, VIC VBA, QLD QBCC, WA Building Commission) for specific requirements.

Step-by-Step Guide

Step 1: Site Selection and Planning

Choose a level, stable site near a downpipe and where the tank will not obstruct access or views. Consider the tank's full weight (e.g., a 2,000L tank weighs over 2 tonnes when full). Ensure sufficient clearance around the tank for maintenance and future access. Check local council regulations for setbacks and maximum tank height.

Step 2: Prepare the Tank Foundation

A stable, level foundation is crucial to prevent tank damage and ensure longevity.

Option A: Concrete Slab (Recommended for larger tanks)

1. Mark out the slab area, ensuring it's slightly larger than the tank''s base diameter (e.g., 100mm wider all around).

2. Excavate the area to a depth of 100-150mm, ensuring a level base.

3. Construct formwork using 70x35mm treated pine around the perimeter, securing it with stakes.

4. Lay a 200 micron damp-proof membrane over the excavated area, overlapping edges by 300mm.

5. Place reinforcing mesh (e.g., SL72) on plastic bar chairs (75mm high) to ensure it's in the middle of the slab.

6. Mix and pour concrete (e.g., 1 part cement, 2 parts sand, 3 parts aggregate) into the formwork, ensuring it's level and smooth using a screed and float.

7. Allow concrete to cure for at least 7 days before placing the tank.

Option B: Crushed Rock Base (Suitable for smaller tanks)

1. Mark out the area, slightly larger than the tank's base.

2. Excavate to a depth of 100-150mm.

3. Lay geotextile fabric to prevent weed growth and base material migration.

4. Fill the area with compacted crushed rock/road base (e.g., DGB20) in layers of 50mm, compacting each layer with a plate compactor or hand tamper. Ensure the surface is perfectly level.

Step 3: Install Tank Inlet and First Flush Diverter

The first flush diverter prevents the initial dirty rainwater from entering the tank.

1.Identify the downpipe(s) that will feed the tank.
2.Cut the downpipe at a suitable height to allow for the first flush diverter and tank inlet.
3.Install a downpipe adaptor (e.g., 90mm round to 100x50mm rectangular) to connect to the first flush diverter.
4.Assemble the first flush diverter according to manufacturer instructions, ensuring it's plumb and securely attached. The length of the diverter pipe depends on the roof area (e.g., 10L per 10m² of roof area).
5.Connect the outlet of the first flush diverter to the tank's inlet, typically via a 90mm or 100mm PVC pipe. Ensure a leaf filter/strainer is installed at the tank inlet. Use PVC cement and primer for all PVC connections.

Step 4: Install Tank Overflow

The overflow pipe directs excess water away from the tank once it's full.

1.Locate the overflow connection point on the tank (usually near the top).
2.Connect a 90mm or 100mm PVC pipe to the tank's overflow outlet.
3.Route the overflow pipe to a suitable discharge point, such as a stormwater drain, garden bed, or soakage trench, ensuring it flows downhill.
4.Ensure the overflow pipe has a screened end to prevent vermin entry. All connections must be sealed with PVC cement and primer.

Step 5: Install Tank Outlet and Ball Valve

This allows controlled access to the stored rainwater.

1.Locate the tank's outlet connection point (usually near the bottom).
2.Apply PTFE thread tape (at least 10-15 wraps) to the threads of the brass tank outlet fitting.
3.Carefully screw the brass tank outlet into the tank, ensuring it's hand-tight, then tighten with an adjustable wrench for a secure, leak-free seal. Do not overtighten.
4.Attach a ball valve (matching the outlet size, e.g., 25mm or 32mm) to the tank outlet, again using PTFE tape.

Step 6: Connect Pump (Optional)

If you plan to use the water for pressure applications (e.g., garden hose, toilet flushing).

1.Position the pump on a stable, level surface near the tank, ideally on a small concrete slab or pavers.
2.Connect the tank outlet to the pump's inlet using a flexible hose and stainless steel hose clamps. Ensure the hose is rated for suction.
3.Install a pre-filter between the tank and the pump to protect the pump from sediment.
4.Connect the pump's outlet to your desired irrigation system or internal plumbing (e.g., 25mm or 32mm poly pipe).
5.IMPORTANT: All electrical connections for the pump must be performed by a licensed electrician. Ensure the pump is protected from the elements with a pump cover if exposed.

Step 7: Final Checks and Commissioning

1.Inspect all connections for leaks, especially around the tank outlet, overflow, and pump connections.
2.Ensure the leaf filter and first flush diverter are correctly installed and clear.
3.Open the ball valve at the tank outlet.
4.Wait for rain! Observe the system during the first rainfall to ensure proper operation of the first flush diverter, tank filling, and overflow.

Common Mistakes to Avoid

1.Inadequate Foundation: A non-level or unstable base can lead to tank bulging, cracking, and premature failure.
2.Incorrect Pipe Sizing: Using undersized pipes for inlets or overflows can lead to blockages or inefficient water collection/discharge.
3.No First Flush Diverter: Skipping this step allows roof debris, dust, and contaminants to enter the tank, reducing water quality.
4.Poor Sealing: Leaky connections waste water and can cause structural damage to the tank or surrounding area. Always use appropriate sealants and thread tape.
5.Ignoring Council Regulations: Failing to check local council requirements for tank installation can lead to fines or forced removal.

Pro Tips

Maximise Collection: Connect multiple downpipes to your tank for faster filling, especially from larger roof areas. Regular Maintenance: Periodically clean your leaf filter, first flush diverter, and tank inlet to ensure optimal water quality and flow. Water Quality: If using rainwater for potable purposes, ensure the tank is food-grade, and consider additional filtration and UV sterilisation. Always check AS/NZS 3500.1 for potable water connections. Pump Protection: Install a pump cover to extend the life of your pump by protecting it from sun, rain, and debris. Future Proofing: Consider installing a mains water top-up system for your tank if you plan to use it for internal applications like toilets or laundry, ensuring a continuous supply during dry periods. This requires backflow prevention and must be installed by a licensed plumber in accordance with AS/NZS 3500.1.

Recommended Tools

Milwaukee M18 FUEL Impact Drill: Powerful and versatile for drilling and driving, essential for various installation tasks. Ridgid 150-L Quick-Acting Tubing Cutter: For clean, precise cuts on PVC and poly pipe, saving time and effort compared to a hacksaw. Stanley FatMax Tape Measure: Durable and accurate, with a strong blade stand-out for single-person measurements. Spear & Jackson Fibreglass Handle Shovel: Robust and comfortable for excavation, reducing fatigue during site preparation. Plumb-Boss PVC Cement & Primer Kit: Ensures strong, leak-

Frequently asked questions

What is involved in install a rainwater tank for home use?
This guide details the process of installing a rainwater tank system for home use, focusing on collecting water from a roof and connecting it for garden irrigation or toilet flushing. It covers site selection, foundation preparation, tank installation, and connecting the necessary plumbing component
What skill level do I need for install a rainwater tank for home use?
Intermediate — Estimated time: 1-2 days (excluding concrete curing time)
What are common mistakes when install a rainwater tank for home use?
1. Inadequate Foundation: A non-level or unstable base can lead to tank bulging, cracking, and premature failure. 2. Incorrect Pipe Sizing: Using undersized pipes for inlets or overflows can lead to blockages or inefficient water collection/discharge. 3. No First Flush Diverter: Skipping this step allows roof debris, dust, and contaminants to enter the tank, reducing water quality.
What tools do I need for install a rainwater tank for home use?
This guide includes a comprehensive tools list. Key plumbing tools are detailed in the Tools Required section.
What Australian standards apply to rainwater tanks?
Rainwater tanks must comply with specific Australian Standards. Polyethylene tanks should meet AS/NZS 4766:2006, while steel tanks often reference AS/NZS 4020:2018 for water contact. All plumbing connections must adhere to AS/NZS 3500.1:2021, ensuring safe and compliant installation for domestic use.
What is the Australian standard for rainwater tanks?
The primary Australian standard for polyethylene rainwater tanks is AS/NZS 4766:2006, which specifies requirements for material, design, and manufacturing. For tanks intended for drinking water, compliance with AS/NZS 4020:2018 for products in contact with drinking water is also crucial. Always check the tank's compliance documentation.
Do I need a permit to install a rainwater tank in Australia?
Permit requirements for rainwater tank installation vary by state and local council in Australia. Generally, tanks over a certain size (e.g., 5,000 litres) or those connected to internal plumbing may require council approval or a plumbing permit. Always consult your local council's planning department before commencing work.
What is a first flush diverter and why is it important?
A first flush diverter is a device that prevents the initial flow of water from the roof, which often contains debris, dust, and contaminants, from entering the rainwater tank. According to best practice guidelines from state water authorities, this improves water quality and reduces sediment build-up, especially if the water is used for potable purposes or garden irrigation.

Written by Pipey, the Plumbing specialist at VIC.Tools.