How to install an under-sink water filter
🔧 Installing an Under-Sink Water Filter An under-sink filter connects to the kitchen’s cold-water supply and delivers filtered water through either a dedicated drinking-water tap or a compatible three-way mixer. This guide covers a typical cartridge-style system using 6.35 mm (1/4 in) tubing
Quick answer
To install an under-sink water filter in Australia, isolate the cold-water supply, tee into the DN 15 service using a WaterMark-approved dual-check isolation valve and 350–500 kPa pressure limiter, mount the filter bracket, and route 6.35 mm food-grade tubing to a dedicated tap. AS/NZS 3500.1 mandates WaterMark-certified components and licensed plumbing execution.
- Skill level
- Intermediate
- Time
- 2–4 hours
- Trade
- Plumbing
- Updated
- 28 November 2026
Tools you will need
- Adjustable spanner, approximately 200
- Basin wrench or tap
- Step drill suitable for thin stainless steel
- Cordless drill with variable speed and side handle
- Tube cutter suitable for 6.35 mm
- Phillips and flat
- Measuring tape and permanent marker
- Spirit level
- Bucket and absorbent towels
- Torch or headlamp
How does an under-sink water filter system work?
🔧 Installing an Under-Sink Water Filter
An under-sink filter connects to the kitchen’s cold-water supply and delivers filtered water through either a dedicated drinking-water tap or a compatible three-way mixer. This guide covers a typical cartridge-style system using 6.35 mm (1/4 in) tubing connected to a DN 15 (15 mm) cold-water service.
Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials. The installation must comply with the Plumbing Code of Australia (PCA), NCC Volume Three, AS/NZS 3500.1, applicable WaterMark requirements and local plumbing regulations.Who is legally allowed to install an under-sink water filter in Australia?
Intermediate — Estimated time: 2–4 hours
A licensed plumber should make or alter the potable water connection. Drilling the benchtop and mounting the filter may be suitable for a capable homeowner, subject to the benchtop manufacturer’s requirements.
What tools are required to install an under-sink water filter?
What materials and certifications are needed for an under-sink filter installation?
Use components suitable for potable water and carrying the required WaterMark certification. Do not substitute irrigation fittings, generic pneumatic tubing or non-approved valves.
Safety Requirements
⚠️ Safety
🔒 Licensing
Plumbing licensing is administered by the relevant state or territory regulator, including NSW Fair Trading, the Victorian Building Authority (VBA), the Queensland Building and Construction Commission (QBCC) and the relevant WA building and plumbing regulator, historically referred to as the WA Building Commission. Requirements differ between jurisdictions, so verify whether a compliance certificate or notification is required.
Step-by-Step Guide
Step 1: 1️⃣ Select the Filter System
Choose a filter based on the contaminants you want to reduce and the quality of the incoming water.
Check that the complete assembly and all plumbing components are approved for use with Australian potable-water systems. Review:
💡 A high flow rating is useful, but contact time is also important. Do not fit an oversized tap that draws water faster than the cartridge’s rated treatment flow.
Step 2: 2️⃣ Inspect the Existing Plumbing
Empty the cabinet and identify the cold-water supply. In most Australian kitchens, the tap connection is supplied from a DN 15 (15 mm) service through an isolation valve and flexible connector.
Check for:
Operate the existing isolation valve gently. If it will not close fully, leaks around the spindle or is not WaterMark approved, have it replaced by a licensed plumber.
Step 3: 3️⃣ Plan the Layout
Position the filter housings on a cabinet wall where they will remain upright and accessible. Allow the clearance specified by the manufacturer—often at least 50–100 mm below the housing—for cartridge removal.
Plan tubing routes with broad curves. Keep tubing away from:
Mark the bracket holes and proposed tap location. Confirm that the tap can rotate without striking the splashback or mixer.
💡 Install a leak tray beneath the housing where practical, but never rely on the tray as a substitute for correct connections and leak testing.
Step 4: 4️⃣ Isolate and Depressurise the Cold-Water Supply
Place a bucket and towels beneath the cold-water connection.
Do not proceed while the line remains pressurised.
Step 5: 5️⃣ Install the Dedicated Filter Tap
If using an existing sink accessory hole, confirm it matches the tap manufacturer’s required diameter.
For a stainless-steel sink:
Do not overtighten; this can deform a thin stainless-steel sink or damage the gasket.
For stone, porcelain, glass or composite surfaces, use a benchtop professional. Do not assume a spare-looking section is safe to drill.
If using a three-way mixer instead of a dedicated filter tap, select a model with separate internal waterways so filtered water is not mixed with ordinary hot or cold supply. Choose WELS-registered tapware where the product is within the WELS scheme and check its registration details. A 4-star or higher WELS-rated kitchen mixer is generally a water-efficient choice.
Step 6: 6️⃣ Mount the Filter Bracket and Housings
Hold the bracket level against the cabinet wall and mark the fixing points. Before drilling, ensure screws cannot penetrate the outside of the cabinet or strike concealed services.
Fit suitable screws into a solid cabinet panel or reinforced mounting board. Lightweight cabinet backs may not support full filter housings, which become considerably heavier when filled with water.
Secure the filter head or bracket, then install the cartridges in the correct order. Check that:
Do not use petroleum grease on O-rings. Use only manufacturer-approved food-grade lubricant where required.
Step 7: 7️⃣ Connect the Cold-Water Feed
A licensed plumber should make this connection to the potable water service.
The usual arrangement is:
Cold-water isolation valve → approved tee or filter valve → existing kitchen mixer and filter inletUse a WaterMark-certified DN 15 (15 mm) connection valve or tee compatible with the existing fitting. Avoid stacking multiple adaptors, which creates extra leak points and places strain on the pipework.
If an integral shut-off valve is supplied for the filter, position it where it remains accessible. Do not connect the filter using self-piercing saddle valves; they can restrict flow and may not meet Australian plumbing requirements.
Tighten connections according to the fitting manufacturer’s instructions. Hold the body of fixed valves with a second spanner to avoid twisting concealed pipework.
Step 8: 8️⃣ Cut and Fit the Tubing
Measure each run with enough slack for servicing but without loose coils.
For typical 6.35 mm (1/4 in) push-fit tubing, an angled or scratched cut can damage the O-ring and cause a delayed leak. Never cut tubing with side cutters, pliers or a blunt utility knife.
Connect the filter inlet, filter outlet and dedicated tap in accordance with the labelled flow direction.
Step 9: 9️⃣ Restore Water and Check for Leaks
Ensure the filter tap is closed, then reopen the water supply slowly. Sudden pressurisation can dislodge tubing and create water hammer.
Inspect every joint using dry tissue or paper towel. Check:
Open the filter tap slowly to purge trapped air. Initial sputtering and cloudy-looking water caused by air can be normal. If a leak appears, isolate the water immediately, depressurise the system and rectify the joint—never tighten or dismantle a pressurised fitting.
Step 10: 🔟 Flush and Commission the Filter
Flush the cartridges exactly as directed by the manufacturer. Carbon filters commonly release fine black carbon particles during initial flushing.
Depending on the product, flushing may require:
Do not drink the initial flush water. Check that the finished water runs clear and has no unusual odour.
Measure the flow if required and verify that it does not exceed the cartridge’s rated treatment flow. Recheck all joints under operating pressure.
Step 11: 1️⃣1️⃣ Record Maintenance and Finalise the Installation
Write the installation date and replacement date on the cartridge label. Keep the filter model and cartridge part number inside the cabinet.
Reinspect the installation:
Replace cartridges at the manufacturer’s time or volume limit, whichever comes first. Replace them sooner if flow drops significantly, taste or odour returns, or local water quality conditions require it.
If the home has been unoccupied for an extended period, flush the filter before use. Follow the manufacturer’s sanitising or cartridge-replacement instructions after prolonged stagnation.
Common Mistakes to Avoid
Pro Tips
Recommended Tools
Frequently asked questions
- What is involved in install an under-sink water filter?
- 🔧 Installing an Under-Sink Water Filter An under-sink filter connects to the kitchen’s cold-water supply and delivers filtered water through either a dedicated drinking-water tap or a compatible three-way mixer. This guide covers a typical cartridge-style system using 6.35 mm (1/4 in) tubing
- What skill level do I need for install an under-sink water filter?
- Intermediate — Estimated time: 2–4 hours
- What are common mistakes when install an under-sink water filter?
- 1. Connecting to the hot-water line — most under-sink cartridges and tubing are designed only for cold potable water. 2. Using non-approved fittings — irrigation valves, pneumatic fittings and uncertified tubing may not be suitable for drinking water or Australian mains pressure. 3. Cutting tubing at an angle — poor cuts can damage push-fit seals and cause slow or delayed leakage. 4
- What tools do I need for install an under-sink water filter?
- This guide includes a comprehensive tools list. Key plumbing tools are detailed in the Tools Required section.
- Do you need a licensed plumber to install an under-sink water filter in Australia?
- Yes, connecting an under-sink water filter directly to the mains drinking-water supply requires a licensed plumber under the Plumbing Code of Australia (NCC Volume Three). While homeowners may mount brackets or drill sink tap landings, all physical connections to the DN 15 cold-water service and isolation valves constitute regulated plumbing work across all Australian states and territories.
- What Australian standard applies to under-sink water filter installations?
- Under-sink water filter installations are governed by AS/NZS 3500.1:2021 (Plumbing and drainage — Water services) and the WaterMark Certification Scheme (WMTS-103). These standards require backflow prevention, dynamic pressure control not exceeding 500 kPa, and certified food-grade polyethylene tubing rated to withstand Australian mains pressure.
- Why do under-sink water filters require a pressure limiting valve?
- Under-sink filter housings and 6.35 mm (1/4 in) polyethylene tubing typically have a maximum operating threshold of 500 kPa. Because Australian mains water pressure can spike above 1,000 kPa during off-peak hours, AS/NZS 3500.1 mandates an inline pressure limiting valve (PLV) to prevent housing rupture and catastrophic internal flooding.
- Can an under-sink filter be connected to a hot-water line?
- No, under-sink water filter cartridges and standard polyethylene tubing must only be connected to the cold-water service. Hot water degrades activated carbon blocks, compromises polypropylene sediment membranes, melts standard push-fit seals, and can leach manufacturing chemicals into the potable water supply.
Written by Pipey, the Plumbing specialist at VIC.Tools.