Skip to main content

How to relight a gas hot water system pilot light

Learn how to relight a gas hot water system pilot light safely. Follow Australian standards to clear residual gas, ignite the burner, and restore hot water.

Quick answer

Relighting a gas hot water pilot light requires isolating the valve to off for five minutes to clear residual gas. Turn the control to pilot, depress the knob, and strike the piezo igniter. Hold the knob down for twenty seconds to heat the thermocouple, then release and adjust the temperature setting.

Skill level
Beginner
Time
15–30 minutes
Trade
Plumbing
Updated
28 November 2026

Tools you will need

  • Ledlenser H8R - Rechargeable LED Headlamp
  • Supa-Peg - Extra Long Reach Utility Gas Lighter
  • Wiha SoftFinish - 6.5mm Slotted Flathead Screwdriver
  • Mechanix Wear Specialty 0.5mm - High-Dexterity Work Gloves
  • Tradie Gear - Heavy-Duty Kneeling Pad

🔧 How to Relight a Gas Hot Water System Pilot Light

Why might a gas hot water system pilot light go out?

If your older gas storage hot water system has suddenly stopped producing hot water, a blown-out pilot light is a common cause. This guide explains the usual relighting process for Australian standing-pilot gas hot water units, but you must always follow the manufacturer’s instructions on the unit data plate or manual first.

Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials.

What skill level is required to relight a gas hot water system pilot light?

Beginner — Estimated time: 15–30 minutes

What tools are required to relight a gas hot water system pilot light?

Long-neck gas lighter or BBQ igniter
Torch or headlamp for viewing the burner compartment
Flat-blade screwdriver (only if the access cover or viewing port requires it)
Phone camera to photograph the instruction label before starting
Work gloves for handling metal access panels

What materials are needed to relight a gas hot water system pilot light?

Manufacturer’s lighting instructions from the unit label or manual
Replacement access panel clips or screws if any are missing
Clean rag for wiping dust from the control area
New batteries only if the unit has battery-assisted ignition rather than a true standing pilot

What safety precautions must be taken when relighting a gas hot water system pilot light?

Gas work requires a separate gas fitter licence in Australia.
If you can smell gas, do not attempt to relight the unit.
Turn the gas control to OFF if safe to do so, ventilate the area, keep all flames and sparks away, and contact a licensed gas fitter.
Never use matches inside an enclosed burner chamber unless the manufacturer specifically allows it. A long-neck igniter is safer.
Do not force the gas control knob. If it is jammed, damaged, or loose, stop and call a licensed plumber/gas fitter.
Follow the PCA, AS/NZS 3500 for plumbing context, and especially AS/NZS 5601.1 for gas installations.
In Australia, gas and plumbing licensing is regulated by state authorities such as NSW Fair Trading, VIC VBA, QLD QBCC, and the WA Building Commission.
WELS star ratings are generally not applicable to relighting a pilot light, but if replacement is needed, consider an efficient hot water upgrade.

Step-by-Step Guide

Step 1: 1️⃣ Identify your hot water system type

Check whether your unit is an older gas storage hot water system with a standing pilot. Look for a gas control valve marked OFF / PILOT / ON, a small viewing window, and lighting instructions on the front panel.

If your system has an electronic ignition, digital control, or no visible pilot instructions, this guide may not apply. In that case, use the manufacturer’s reset procedure or call a licensed plumber/gas fitter.

Step 2: 2️⃣ Make the area safe before doing anything

Stand near the unit and check for any smell of gas. If you smell gas strongly, hear hissing, or suspect a leak, do not continue.

Turn off ignition sources nearby, do not use switches or power tools in the area, and ventilate the space. If safe, turn the gas control to OFF and wait for professional assistance.

Step 3: 3️⃣ Read the lighting instructions on the unit

Most Australian gas storage units have a label showing the exact relighting sequence. Take a clear photo of the instructions with your phone so you can refer to them while working.

Different brands such as Rheem, Dux, Aquamax, and Vulcan may vary slightly. Always follow the unit’s label over any general guide.

Step 4: 4️⃣ Turn the control knob to OFF and wait

If there is no gas smell and the area is safe, turn the gas control knob to OFF. Wait at least 5 minutes so any unburnt gas in the combustion chamber can disperse.

This waiting period is important. Trying to relight too early can cause a flare-up or failed ignition.

Step 5: 5️⃣ Set the control to PILOT

After waiting, turn the knob to PILOT. Open the viewing port or access panel if required so you can see the pilot area.

Some systems require you to press and hold the control knob down to allow gas to flow to the pilot. Others have a separate red pilot button. Check the label carefully.

Step 6: 6️⃣ Ignite the pilot flame

While holding the control knob or pilot button down, place the flame from a long-neck lighter at the pilot burner as shown in the instructions. Keep the button depressed while the pilot lights.

Once the pilot is burning, continue holding the knob/button for about 20–30 seconds, or as specified by the manufacturer. This heats the thermocouple so it can keep the pilot flame established.

Step 7: 7️⃣ Release the button slowly and confirm the pilot stays lit

Release the button gradually. Watch the pilot through the viewing opening.

If the flame stays on, the pilot has successfully relit. If it goes out immediately, wait 5 minutes and try once more. If it still will not stay lit, the problem may be a faulty thermocouple, dirty pilot jet, gas valve issue, or lack of gas supply.

Step 8: 8️⃣ Turn the control from PILOT to ON

Once the pilot remains stable, turn the gas control knob to ON. The main burner should fire when the thermostat calls for heat.

Listen for the main burner to ignite and check that the flame is steady and normal. Replace any access covers securely after confirming operation.

Step 9: 9️⃣ Check the unit is heating correctly

Allow time for the burner to heat the tank. Depending on tank size, recovery can take 30 minutes to several hours before full hot water is available.

Check later at a hot tap. Water should become hot again, but use caution as storage systems can deliver very hot water before a tempering valve mixes it down.

Step 10: 🔟 Know when to stop and call a licensed professional

If the pilot will not light, will not stay lit, keeps going out, or the burner ignition seems delayed or abnormal, stop troubleshooting. These are signs the unit needs professional service.

Common faults include a failed thermocouple, blocked pilot assembly, faulty gas control valve, poor combustion air, or flueing problems. These require a licensed plumber/gas fitter.

Common Mistakes to Avoid

1.Skipping the 5-minute wait time after turning the gas control to OFF.
2.Trying to relight the system when there is a clear smell of gas.
3.Using excessive force on the gas valve or buttons.
4.Confusing an electronic ignition unit with a standing-pilot unit.
5.Repeatedly attempting ignition without checking whether the gas supply is actually turned on.
6.Leaving the access cover off after relighting, which can affect safe burner operation.
7.Ignoring repeated pilot failures, which often indicate a component fault rather than a one-off outage.

Pro Tips

💡 Take a photo of the model number and data plate before starting. This makes it easier to find the correct manual or book a service call.
💡 If the pilot keeps blowing out on windy days, the issue may be related to flueing, draughts, or burner chamber sealing rather than the igniter itself.
💡 A pilot that lights but will not stay on often points to a worn thermocouple or dirty pilot assembly.
💡 If your gas storage unit is older and unreliable, compare replacement options such as a 5-star or better gas storage system, 26–30 L/min continuous flow gas, or an energy-efficient heat pump where suitable.
💡 If you are replacing fixtures during a hot water upgrade, choose taps and showers with strong WELS ratings to reduce hot water use.

Recommended Tools

Long-neck BBQ lighter — safer reach into pilot access areas
LED headlamp — keeps both hands free while viewing the pilot flame
Flat-blade screwdriver set — useful for access panels and covers
Phone with camera/torch — ideal for reading faded instruction labels
Work gloves — helps protect hands from sharp sheet-metal edges

🔒 Licensing: Relighting a pilot light may seem simple, but any fault-finding, repairs, gas leak investigation, burner servicing, thermocouple replacement, or valve work must be carried out by a licensed plumber with the appropriate gas fitter licence. In Australia, check licensing requirements through NSW Fair Trading, VIC VBA, QLD QBCC, or the WA Building Commission.

Frequently asked questions

How do you relight a gas hot water system pilot light?
To relight a gas hot water pilot light, turn the control knob to OFF and wait five minutes to clear residual gas. Turn the knob to PILOT, depress it fully, and press the piezo igniter repeatedly until lit. Hold the knob down for twenty seconds before releasing and adjusting the temperature.
Why does a gas hot water pilot light keep going out?
A gas hot water pilot light typically goes out due to a faulty thermocouple, a blocked pilot injector, or strong downdrafts through the flue. If the thermocouple fails to generate the millivolt current required to keep the gas valve open, the safety mechanism cuts the gas supply instantly.
How long should you wait before relighting a gas pilot light?
You must wait a minimum of five minutes before attempting to relight a gas hot water system pilot light. This critical safety pause allows any unburnt, accumulated gas inside the combustion chamber to dissipate into the atmosphere, preventing dangerous flare-ups or small explosions when ignition is struck.
Can a homeowner legally relight a gas hot water pilot light in Australia?
Yes, homeowners can legally relight a standing pilot light using the manufacturer instructions located inside the access panel. However, under AS/NZS 5601.1:2022, any repairs, component replacements such as thermocouples, or gas line adjustments must be carried out exclusively by a licensed gas fitter.
How do you know if a hot water system has electronic ignition or a pilot light?
Storage units with a continuous standing pilot light feature a visible gas control valve with a manual spark piezo or match hole. Continuous-flow systems like Rinnai Infinity and modern storage tanks use electronic pulse ignition, relying on mains electricity or internal hydro-generators without any permanent pilot flame.
What should you do if you smell gas around the hot water heater?
If you smell gas, do not attempt to light the pilot, operate electrical switches, or create naked flames. Immediately isolate the gas supply at the main meter or cylinder valve, ventilate the surrounding outdoor area, and contact a licensed gas fitter or your gas network emergency hotline.

Written by Pipey, the Plumbing specialist at VIC.Tools.