How to replace a hot water system tempering valve

This guide details the process of replacing a faulty tempering valve on a hot water system, ensuring compliance with AS/NZS 3500.4 and maintaining safe hot water delivery temperatures. A tempering valve mixes hot water from the storage tank with cold water to deliver tempered hot water at a maximum

Skill level
Intermediate
Time
1-2 hours
Trade
Plumbing
Updated
28 November 2026

Tools you will need

  • Adjustable spanners
  • Pipe wrenches
  • Multi
  • Tube cutter
  • PEX crimping tool or press
  • Deburring tool
  • Bucket or drain pan
  • Rags
  • Digital thermometer
  • Thread sealant

What is a hot water system tempering valve and why is it important?

This guide details the process of replacing a faulty tempering valve on a hot water system, ensuring compliance with AS/NZS 3500.4 and maintaining safe hot water delivery temperatures. A tempering valve mixes hot water from the storage tank with cold water to deliver tempered hot water at a maximum of 50°C to sanitary fixtures, preventing scalding.

What skill level is required to replace a hot water system tempering valve?

Intermediate — Estimated time: 1-2 hours

What tools are required to replace a hot water system tempering valve?

Adjustable spanners (250mm and 300mm) Pipe wrenches (300mm for larger pipe sizes) Multi-grips Tube cutter (for copper pipe, if applicable) PEX crimping tool or press-fit tool (if applicable) Deburring tool Bucket or drain pan Rags Digital thermometer (with probe for water temperature measurement) Thread sealant (PTFE tape or liquid sealant suitable for potable water) Wire brush (for cleaning threads)

What materials are needed for a tempering valve replacement?

New tempering valve (AS/NZS 4032.2 compliant, suitable for potable water, appropriate size for existing pipework – typically 20mm or 25mm). Ensure it's a Type 1 or Type 2 valve as per AS/NZS 3500.4. Isolation valves (if not already present and required for future maintenance – 20mm or 25mm ball valves) Pipe fittings (e.g., brass olives, compression nuts, PEX crimp rings, press-fit fittings) if modifying pipework. Copper pipe or PEX pipe (if pipework modification is necessary)

What are the essential safety requirements for replacing a tempering valve?

⚠️ ALWAYS turn off the power/gas supply to the hot water system before commencing work. ⚠️ ALWAYS isolate the cold water supply to the hot water system. ⚠️ ALWAYS wear appropriate Personal Protective Equipment (PPE), including safety glasses and gloves. ⚠️ BE AWARE of hot water and steam when draining the system. Allow water to cool if possible. ⚠️ ENSURE the work area is well-ventilated, especially if working with gas appliances. ⚠️ NEVER attempt gas work unless you hold a separate, valid gas fitter's licence. This guide focuses solely on the plumbing aspects of tempering valve replacement.

Step-by-Step Guide

Step 1: 1️⃣ Isolate Services and Drain System

Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials.

Locate the hot water system. Turn off the electrical supply at the circuit breaker or the gas supply at the appliance isolation valve. Turn off the main cold water supply to the hot water system. This is usually a ball valve on the cold water inlet pipe. Open a hot water tap at the highest point in the house to break any vacuum and allow air into the system. Open a hot water tap at the lowest point in the house (e.g., laundry tub) or the drain valve on the hot water tank to relieve pressure and drain some water from the hot water outlet pipe, particularly the section leading to the tempering valve. Use a bucket or drain pan to catch the water.

Step 2: 2️⃣ Locate and Prepare for Valve Removal

Identify the existing tempering valve. It will typically be located on the hot water outlet pipe, mixing with a cold water line before the tempered hot water supply branches off to fixtures. Place rags and a bucket beneath the valve to catch any residual water when it's disconnected. Inspect the existing pipework configuration. Note the connections (e.g., compression, threaded, soldered, PEX).

Step 3: 3️⃣ Remove the Old Tempering Valve

Using adjustable spanners or pipe wrenches, carefully loosen the connections on the hot water inlet, cold water inlet, and tempered water outlet of the existing valve. Support the pipework to prevent strain or damage to other connections. Once all connections are loose, remove the old tempering valve. Be prepared for some water to spill out. Clean the pipe threads or ends thoroughly with a wire brush or rag to ensure a good seal for the new valve.

Step 4: 4️⃣ Install the New Tempering Valve

Ensure the new tempering valve is oriented correctly according to the flow arrows marked on its body (Hot In, Cold In, Tempered Out). Apply thread sealant (PTFE tape or liquid sealant) to all male threaded connections. For compression fittings, ensure olives are correctly seated. Connect the hot water inlet pipe to the hot inlet port of the new valve. Connect the cold water supply pipe to the cold inlet port of the new valve. Connect the tempered water outlet pipe to the tempered outlet port of the new valve. Hand-tighten all connections, then use spanners to firmly tighten them. Avoid over-tightening, especially with plastic components or compression fittings, as this can cause damage.

Step 5: 5️⃣ Restore Water Supply and Test for Leaks

Slowly open the main cold water supply valve to the hot water system. Check all new connections for leaks immediately. Tighten any weeping connections carefully. Once the system is repressurised, close the hot water tap that was opened at the lowest point. Allow the hot water system to fill completely. Air will be expelled from the open hot water tap at the highest point. Close this tap once water flows steadily.

Step 6: 6️⃣ Restore Power/Gas and Adjust Temperature

Turn on the electrical supply or gas supply to the hot water system. Allow the system to heat up fully. This may take some time depending on the tank size and heating method. Once the water is hot, open a hot water tap (e.g., bathroom basin) and allow it to run for a few minutes until the temperature stabilises. Using a digital thermometer, measure the temperature of the tempered hot water at the tap. Adjust the tempering valve's adjustment screw (usually located on the valve body) until the water temperature at the tap is between 45°C and 50°C. AS/NZS 3500.4 mandates a maximum of 50°C at the outlet of sanitary fixtures used for personal hygiene. Re-check the temperature after adjustment to confirm compliance.

Common Mistakes to Avoid

1.Incorrect Valve Orientation: Installing the tempering valve backwards or with incorrect hot/cold/tempered connections will prevent it from functioning correctly or at all. Always check flow arrows.
2.Insufficient Thread Sealant: Leads to leaks. Ensure adequate PTFE tape (wrapped clockwise) or liquid sealant is applied.
3.Over-tightening Connections: Can strip threads, crack fittings, or damage the valve body, leading to leaks or premature failure.
4.Not Isolating Services: Extremely dangerous. Failure to turn off power/gas and water supply can lead to electric shock, burns, or flooding.
5.Incorrect Temperature Setting: Setting the tempered water temperature above 50°C at the fixture is a breach of AS/NZS 3500.4 and poses a scalding risk.

Pro Tips

💡 Pre-assemble: If possible, assemble any necessary fittings onto the new tempering valve before installing it into the pipework. 💡 Isolation Valves: If the existing system lacks isolation valves on the hot and cold lines leading to the tempering valve, consider installing them during this replacement. This makes future maintenance much easier. 💡 WELS Rating: While tempering valves don't have a WELS rating, ensuring your hot water system and fixtures are WELS-rated contributes to overall water efficiency. 💡 Check Pressure: If you suspect high water pressure, consider installing a pressure limiting valve (PLV) on the main cold water inlet to the property or hot water system, as high pressure can affect valve longevity. 💡 Record Settings: Note the final temperature setting and the date of replacement for future reference.

Recommended Tools

Ridgid 31090 10" Aluminium Pipe Wrench: Lightweight yet strong for gripping and turning pipes and fittings. Knipex Cobra Water Pump Pliers (250mm): Excellent grip and adjustability for various nuts and pipes, reducing the need for multiple spanners. Rothenberger Rocut 42 Tube Cutter: Provides clean, burr-free cuts on copper pipe, essential for good compression or soldered joints.
Fluke 59 MAX Infrared Thermometer: Quick and accurate non-contact temperature measurement for checking pipe surface temperatures, complementing probe thermometer for water.

🔒 Licensing: Plumbing work in Australia, including the replacement of hot water system components like tempering valves, requires a licensed plumber. Refer to your state's licensing body (e.g., NSW Fair Trading, VIC VBA, QLD QBCC, WA Building Commission) for specific requirements. Gas work requires a separate gas fitter licence.

Frequently asked questions

What is involved in replace a hot water system tempering valve?
This guide details the process of replacing a faulty tempering valve on a hot water system, ensuring compliance with AS/NZS 3500.4 and maintaining safe hot water delivery temperatures. A tempering valve mixes hot water from the storage tank with cold water to deliver tempered hot water at a maximum
What skill level do I need for replace a hot water system tempering valve?
Intermediate — Estimated time: 1-2 hours
What are common mistakes when replace a hot water system tempering valve?
1. Incorrect Valve Orientation: Installing the tempering valve backwards or with incorrect hot/cold/tempered connections will prevent it from functioning correctly or at all. Always check flow arrows. 2. Insufficient Thread Sealant: Leads to leaks. Ensure adequate PTFE tape (wrapped clockwise) or liquid sealant is applied. 3. Over-tightening Connections: Can strip threads, crack fit
What tools do I need for replace a hot water system tempering valve?
This guide includes a comprehensive tools list. Key plumbing tools are detailed in the Tools Required section.
What is the Australian standard for hot water tempering valves?
The Australian standard for hot water tempering valves is AS/NZS 4032.2, which specifies requirements for thermostatic mixing valves for hot water supply. Additionally, AS/NZS 3500.4:2021, the Plumbing and drainage – Hot water supply systems, mandates that tempered water delivered to sanitary fixtures must not exceed 50°C.
How often should a hot water tempering valve be replaced?
While there's no strict national mandate for replacement frequency, many manufacturers recommend inspecting tempering valves annually and replacing them every 5-7 years, or sooner if performance issues like inconsistent temperature or reduced flow are observed. Regular maintenance helps ensure compliance with AS/NZS 3500.4 and prevents scalding.
Can I replace a hot water tempering valve myself in Australia?
In most Australian states and territories, the replacement of a hot water tempering valve is considered plumbing work that must be carried out by a licensed plumber. This ensures compliance with the Plumbing Code of Australia (PCA) and relevant state regulations, protecting against improper installation and potential safety hazards.
What is the maximum hot water temperature allowed in Australian homes?
According to AS/NZS 3500.4:2021, the maximum hot water temperature delivered to sanitary fixtures (like showers and basins) in Australian homes must not exceed 50°C. This is a critical safety measure to prevent scalding, particularly for children, the elderly, and people with disabilities.

Written by Pipey, the Plumbing specialist at VIC.Tools.