Skip to main content

How to replace flexi hoses under a sink

Learn how to replace flexi hoses under a sink safely. Follow Australian standards, isolate water supplies, and install WaterMark-certified connectors.

Quick answer

Replacing flexi hoses under a sink involves isolating the water supply, relieving line pressure, unscrewing the damaged hose, and fitting an AS/NZS 3500.1 compliant WaterMark-certified replacement. Captured rubber washers create the watertight seal without thread tape. In Australia, licensed plumbers must execute mains-connected installations to satisfy national plumbing codes.

Skill level
Beginner / Intermediate
Time
30 minutes to 1 hour for a direct like-for-like replacement on an accessible under-sink hose
Trade
Plumbing
Updated
28 November 2026

Tools you will need

  • Bahco 8072 - 250 mm Adjustable Wrench
  • Knipex 87 01 180 - Cobra Water Pump Pliers
  • Monument 345V - Tap Backnut Spanner
  • Ledlenser H8R - Rechargeable LED Headlamp
  • Ox Tools 10 L - Heavy Duty Trade Bucket
  • Stanley FatMax 5 m - Tape Measure

🔧 How to replace flexi hoses under a sink safely and correctly

Why is it important to replace flexi hoses under a sink promptly?

Burst or leaking flexi hoses under a sink can cause fast, expensive water damage, so the first priority is isolating the water and confirming exactly which hose has failed. Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials.

This job is usually a straightforward like-for-like replacement where the hose remains fully visible and accessible inside the cabinet, but correct sizing, thread matching, installation angle, and pressure suitability are critical. Relevant compliance references include the Plumbing Code of Australia (PCA) and AS/NZS 3500.1 for water services; all replacement hoses should be WaterMark-approved for potable water use in Australia.

What skill level is required to replace flexi hoses under a sink in Australia?

Beginner / Intermediate — Estimated time: 30 minutes to 1 hour for a direct like-for-like replacement on an accessible under-sink hose

What tools are essential for replacing flexi hoses under a sink?

Adjustable spanner, 200 mm to 250 mm
Shifting spanner or multi-grip pliers for holding isolation valve bodies if needed
Torch / headlamp for cabinet visibility
Bucket or shallow tray to catch residual water
Old towels or rags
Tape measure for hose length and fitting checks
Phone camera to photograph existing hose routing and fitting type before removal
Marker pen or masking tape to label hot and cold hoses
Optional: Basin spanner if access is tight behind the sink bowl

What materials are needed for a flexi hose replacement?

Replacement braided flexible tap connector / flexi hose, matching:
existing length, typically 300 mm, 450 mm, or 600 mm
thread size, commonly 15 mm BSP female swivel at the stop tap
mixer tail connection, commonly M10, M12, or manufacturer-specific
WaterMark-approved potable water flexi hose
New sealing washers if supplied or required by the manufacturer
Replacement mini stop tap / isolation valve if the existing valve will not shut off properly or is leaking at the spindle — plumber installation recommended
Optional: new WELS-rated mixer or tap if the hose is integrated and cannot be separately replaced; look for 4 Star WELS or higher where practical

Safety Requirements

Turn off the water at the local isolation valve first; if it does not fully shut off, isolate at the water meter.
Open the tap to relieve pressure before undoing any fittings.
Be careful with hot water lines; trapped hot water can still discharge after isolation.
Keep towels and a bucket ready to control spills and protect cabinetry.
Do not use excessive force on old copper, chrome-plated brass, or plastic fittings.
Do not kink, twist, or sharply bend a new hose; this shortens service life and can cause premature failure.
Only install hoses that are fully visible and accessible after the job; concealed flexible connectors are a compliance and maintenance risk.
🔒 Licensing: Plumbing work in Australia must be carried out by a licensed plumber, with licensing administered by authorities such as NSW Fair Trading, VIC VBA, QLD QBCC, and WA Building Commission. If the job involves altering fixed pipework, replacing valves, changing tapware connections, or dealing with non-compliant fittings, engage a licensed plumber.
Gas work requires a separate gas fitter licence. If there is any gas appliance or gas line in the same cabinet area, do not disturb it.

Step-by-Step Guide

Step 1: 1️⃣ Confirm the leak source

Check whether the leak is actually coming from the flexi hose, not the isolation valve, mixer body, trap, or sink waste.

Dry the area thoroughly with a rag, then turn the water back on briefly and watch closely with a torch. Common flexi hose failure points are:

the braided section itself
the crimped ferrule ends
the swivel nut connection at the stop tap
the mixer tail connection at the tap end

If the valve body itself is leaking, or the hose has caused corrosion or damage to nearby fittings, stop here and call a licensed plumber.

Step 2: 2️⃣ Shut off the water and relieve pressure

Turn off the under-sink mini stop taps for both hot and cold if fitted. If the valve will not close properly, turn off the water at the property water meter.

Open the sink mixer or tap to relieve pressure and drain residual water from the line. Leave the tap open until flow stops.

Place a bucket and towels underneath the hose connection points before loosening anything.

Step 3: 3️⃣ Identify the hose type, length, and thread

Before removing the old hose, photograph both ends and note:

whether it is the hot or cold hose
the hose length, such as 300 mm, 450 mm, or 600 mm
the stop tap connection, commonly 15 mm BSP female
the tap or mixer connection, often M10 or M12
whether the hose seals via a rubber washer, cone seal, or O-ring

This step matters because many flexi hoses look similar but are not interchangeable. The new hose must match the original connection type exactly.

💡 If the hose is integrated into the mixer and does not appear removable separately, the whole mixer may need replacement rather than just the hose.

Step 4: 4️⃣ Remove the old flexi hose

Use one spanner to undo the hose nut and, where necessary, use a second spanner to hold the valve body steady so you do not twist the pipework in the wall or cabinet.

Undo the stop tap end first and allow any remaining water to drain into the bucket. Then disconnect the tap or mixer end.

Inspect the removed hose for:

burst braid
corrosion at the crimp
damaged washer
kinking or twisting
signs the hose was too short and under tension

If the isolation valve thread is damaged, heavily corroded, or loose in the wall, do not proceed with force. That becomes a licensed plumbing repair.

Step 5: 5️⃣ Check the new hose before installation

Confirm the replacement hose is:

WaterMark-approved
suitable for potable water
the same thread type and connection style
long enough to form a gentle curve without tension
not so long that it loops excessively or rubs on sharp cabinet edges

Do not use a hose that has to be stretched to reach. A hose installed under strain is much more likely to fail early.

💡 A correctly sized hose should form a smooth bend, not a sharp kink or spiral twist.

Step 6: 6️⃣ Install the new hose correctly

Start the threads by hand on both ends to avoid cross-threading. If the connection has a sealing washer or O-ring, make sure it is seated correctly and clean.

Tighten the hose according to the fitting type:

Washered swivel nut connections: hand-tighten first, then nip up with a spanner
Mixer tail or O-ring connections: follow manufacturer instructions exactly
Cone or compression-style seals: tighten carefully; overtightening can deform the seal

In most cases, PTFE tape is not required on braided flexi hose swivel nuts because they seal on a washer, cone, or O-ring rather than the thread itself. Only use thread sealant if the manufacturer specifically calls for it.

Make sure the hose:

is not twisted along its length
does not touch sharp metal edges
does not foul the waste trap or stored items
remains visible and accessible for future inspection

Step 7: 7️⃣ Turn the water back on slowly and test

Close the sink tap, then slowly reopen the isolation valve or water meter. Turn the tap on gently and let the line fill.

Check both hose ends carefully with a dry finger or tissue. Even a very small bead of water means the connection is not sealed correctly.

Run both hot and cold for several minutes, then inspect again. Recheck after 10 to 15 minutes and again later in the day.

💡 A dry tissue wrapped briefly around each connection is a simple way to detect a tiny leak you might not see with your eyes.

Step 8: 8️⃣ Final checks and ongoing maintenance

Once the cabinet is dry and leak-free:

remove tools and wet towels
keep the hose visible for future checks
avoid storing chemicals or sharp objects against the hose
inspect all under-sink hoses every 6 to 12 months

If one hose has failed due to age, heat, or corrosion, the matching hose on the other side may be near the end of its service life as well. Consider replacing both hot and cold hoses at the same time.

Common Mistakes to Avoid

1.Buying the wrong hose end fittings, especially confusing 15 mm BSP stop tap threads with M10 or M12 mixer tails.
2.Reusing an old hose that is kinked, twisted, rust-stained, or has damaged braid near the crimp.
3.Using PTFE tape on fittings that seal with a washer or O-ring, which can prevent proper seating and cause leaks.
4.Overtightening the swivel nuts and damaging the washer, valve thread, or mixer tail.
5.Installing a hose that is too short, under tension, rubbing on sharp edges, or hidden behind joinery where it cannot be inspected.

Pro Tips

Choose a hose length that gives a relaxed curve rather than the shortest possible fit; this reduces stress on the crimped ends.
Replace both hot and cold hoses together if they are the same age. If one has failed, the other often is not far behind.
Photograph the old hose and take it to the plumbing supplier to match thread type, length, and seal style accurately.
If the mini stop tap is stiff, leaking, or will not fully isolate, have a licensed plumber replace it at the same time. A new hose on a faulty valve is only half a repair.
💡 If you are replacing the mixer as well, consider a 4 Star WELS or higher tapware product to improve water efficiency without sacrificing everyday performance.

Recommended Tools

Knipex Cobra Water Pump Pliers — excellent grip on valve bodies without excessive slip
Bahco 200 mm Adjustable Wrench — reliable for hose nuts and tight cabinet work
Rothenberger Basin Wrench — useful for hard-to-reach mixer tail connections
Milwaukee Rechargeable Headlamp — improves visibility deep inside under-sink cabinets

Frequently asked questions

Can I replace a flexi hose under my sink myself in Australia?
No, flexible hose replacements connecting to mains water supplies must be performed by a licensed plumber under the Plumbing Code of Australia (PCA). Unlicensed plumbing work breaches state regulations and can void home insurance policies in the event of flood or water damage. Property owners can, however, safely isolate the mini cistern stop valve.
How often should flexible braided hoses be replaced?
Flexible braided hoses should be inspected every six months and replaced every five to ten years depending on the manufacturer's warranty. Hoses showing surface rust, fraying stainless steel braids, kinks, or bulging must be replaced immediately, as these defects signal an imminent burst that can flood premises within minutes.
What size flexi hose do I need for a kitchen sink mixer?
Most Australian kitchen sink mixers connect to standard 15 mm (1/2-inch BSP) male mini cistern stops via 1/2-inch female swivel nuts. The tap end generally uses an M10 or M12 male metric thread. To prevent internal stress, choose a replacement length that provides a gentle, natural curve without kinking.
Should I use thread seal tape on flexi hose connections?
Do not use PTFE thread seal tape on flexible hose swivel nuts or mixer tails. Flexible hoses rely on captive rubber cone washers or O-rings to create a watertight compression seal against the fitting face. Applying thread tape prevents the nut from seating squarely and frequently induces leaks.
What Australian standards apply to flexible plumbing hoses?
Flexible plumbing connectors must comply with AS/NZS 3500.1 (Water services) and carry a visible WaterMark certification mark. Under national regulations, the maximum working pressure should not exceed 500 kPa at the fixture. If local mains pressure exceeds 500 kPa, a pressure-limiting valve must be installed upstream to prevent failure.
How tight should a new flexi hose connection be?
Flexible hose swivel nuts should be tightened hand-tight onto the isolating valve, then turned a further quarter to half turn with a spanner. Avoid overtightening, which distorts or tears the internal rubber washer. Never allow the hose body to twist or rotate while securing the hex nut.

Written by Pipey, the Plumbing specialist at VIC.Tools.