Skip to main content

How to stop a toilet from running

Stop a running toilet in Australia by inspecting the inlet valve, adjusting water levels, or replacing a worn flush seal using WaterMark-certified components.

Quick answer

To stop a running toilet, adjust the float mechanism so water rests twenty millimetres below the overflow pipe, or replace the worn rubber flush valve washer. If water continues flowing into the cistern continuously, replace the complete WaterMark-certified inlet valve. Always shut off the isolating mini-cistern cock before commencing internal repairs.

Skill level
Beginner to Intermediate
Time
30 minutes to 2 hours
Trade
Plumbing
Updated
28 November 2026

Tools you will need

  • Bahco 9031 - 200mm Wide-Jaw Adjustable Spanner
  • Knipex 87 01 250 - Cobra Water Pump Pliers
  • Craftright 6mm x 100mm - Flared Flathead Screwdriver
  • Fluidmaster 400UK063 - WaterMark-Certified Cistern Inlet Valve
  • Caroma 750015 - Dual Flush Outlet Valve Seal
  • Ansell 87-195 - Heavy Duty Neoprene Rubber Gloves
  • McKenzie's 50ml - Food Dye

🔧 How to Stop a Toilet from Running — Diagnose the inlet valve, water level, and outlet seal before replacing the faulty cistern part

What causes a toilet to run continuously in Australia?

A running toilet usually means water is either continuously entering the cistern or leaking from the cistern into the pan. The most common causes are a faulty inlet valve, a worn outlet seal/flush valve seal, or a water level set too high.

Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials. For compliance, toilet plumbing work in Australia should meet the PCA (NCC Volume Three) and relevant parts of AS/NZS 3500.1 and AS/NZS 3500.2.

What skill level is required to fix a running toilet?

Beginner to Intermediate — Estimated time: 30 minutes to 2 hours

What tools are required to fix a running toilet in Australia?

Adjustable spanner, 200 mm to 250 mm
Multigrip pliers
Flat-head screwdriver
Phillips-head screwdriver
Small bucket or tray
Sponge or old towel
Torch or headlamp
Rubber gloves
Food colouring or leak-detection tablets for leak testing
Plastic scraper or soft brush for cleaning mineral build-up

What materials are needed for a toilet repair in Australia?

Replacement inlet valve to suit your cistern, typically 15 mm (1/2" BSP) connection, WaterMark-certified
Replacement outlet valve seal or dual-flush outlet valve to suit the cistern brand/model
Replacement button assembly or linkage, if damaged
Silicone grease suitable for plumbing seals
New flexible connector washer, if the inlet connection is disturbed
Cleaning cloths
Mild descaling solution for mineral build-up
Optional: complete cistern repair kit for common brands such as Caroma, Geberit, R&T, or Fluidmaster-compatible systems

What are the key safety requirements for toilet plumbing repairs?

Turn off the water at the toilet isolation valve before opening the cistern or loosening any fittings.
Flush the toilet to empty as much water from the cistern as possible before working on it.
Ceramic cistern lids are heavy and can chip easily; place the lid on a towel on a flat surface.
Do not use excessive force on plastic cistern parts, as they crack easily.
If water is leaking from the 15 mm supply connection, stop tap, or flexible hose, call a licensed plumber.
If the toilet is connected to a concealed/in-wall cistern, access and repair can be more complex and may require licensed plumbing work.
Only use WaterMark-certified replacement plumbing products in Australia.
If you are replacing connected plumbing components rather than just inspecting them, check licensing requirements in your state: NSW Fair Trading, VIC VBA, QLD QBCC, and WA Building Commission.
Gas work is unrelated to this task, but in Australia any gas work requires a separate gas fitter licence.

Step-by-Step Guide

Step 1: 1️⃣ Confirm where the water is going

First, work out whether the toilet is “running” because the cistern is overfilling or because water is leaking into the pan.

Remove the cistern lid and look inside while the toilet is idle.

You are usually looking for one of these two faults:

Water level too high / inlet valve not shutting off: water rises and spills into the overflow tube, then trickles constantly into the pan.
Outlet valve seal leaking: the cistern fills normally, the inlet valve shuts off, but water slowly leaks past the flush valve seal into the bowl, causing the inlet valve to top up every few minutes.

A quick test is to add a few drops of food colouring to the cistern water and wait 10 to 15 minutes without flushing. If coloured water appears in the pan, the outlet valve seal is leaking.

If the noise is coming from outside the cistern and you can see water around the stop tap, flexible connector, or pan base, that is a different problem and should be checked by a licensed plumber.

Step 2: 2️⃣ Isolate the water and empty the cistern

Turn off the toilet’s isolation valve, usually located on the wall behind or beside the pan on the 15 mm water supply.

Flush the toilet and hold the button or lever down to drain as much water as possible from the cistern. Use a sponge or towel to remove the remaining water from the bottom.

This makes the next checks cleaner and easier, especially if you need to remove the inlet or outlet valve.

Step 3: 3️⃣ Check the flush button, lever, or linkage

Sometimes the toilet keeps running because the flush button or linkage is not returning fully after a flush.

Inspect the following:

Dual-flush buttons sticking in the pressed position
Bent or misaligned button rods
A chain or linkage caught under the cistern lid
Push-button assemblies screwed down too tightly onto the lid

If the button is holding the flush valve slightly open, the cistern will never seal properly.

Loosen and realign the button assembly if needed. With some toilets, simply backing the button nut off slightly can restore free movement.

💡 If the toilet started running just after you replaced the cistern lid or button set, re-check the button rod length and alignment first before replacing any valves.

Step 4: 4️⃣ Check the water level and inlet valve operation

Turn the isolation valve back on briefly and watch the cistern fill.

Most toilets have a marked water line inside the cistern. The water should stop below the overflow opening. If it continues rising and spills into the overflow, the inlet valve is the likely fault.

Common inlet valve issues include:

Float set too high
Dirt or grit caught in the valve
Worn diaphragm or seal
Mineral build-up on moving parts
A float that is sticking on the side of the cistern

Adjust the float first:

On modern valves, use the adjustment screw or clip to lower the shut-off level.
On older float-arm systems, gently bend the arm down slightly if designed for that type.

If adjustment does not help, shut the water off again and inspect the inlet valve filter and diaphragm. Many valves can be dismantled at the top cap for cleaning. Rinse out grit and scale, then reassemble and retest.

If the valve still does not shut off cleanly, replace it with a matching 15 mm WaterMark-certified inlet valve.

Step 5: 5️⃣ Test the outlet valve seal for leaks

If the cistern fills properly and the inlet valve stops, but the toilet still runs intermittently, the problem is usually the outlet valve seal.

Look at the base of the cistern where the flush valve sits. A worn seal may be:

Hardened
Split
Distorted
Coated in scale or debris

Remove the outlet valve cap or canister as per the cistern design. On many dual-flush systems, the upper section twists and lifts out without disconnecting the whole cistern.

Inspect and clean the seating area. Replace the rubber seal if it is worn. Apply a small amount of silicone grease if the manufacturer allows it.

If the whole outlet valve body is cracked or badly worn, replace the complete assembly with a brand-compatible unit.

💡 Always match the new seal or valve to the cistern make and model. A “close enough” seal often causes repeat leaks.

Step 6: 6️⃣ Replace the inlet valve if it won’t shut off

If cleaning and adjusting the inlet valve does not solve the problem, replacement is usually the best fix.

General process:

Turn water off and empty the cistern
Disconnect the water supply from the bottom or side entry valve
Undo the retaining nut
Remove the old valve
Install the new valve with the correct washer orientation
Set the height and float level according to the manufacturer’s instructions
Reconnect the supply and tighten carefully

Do not overtighten plastic threads or cistern nuts. Hand-tight plus a small additional turn is often enough.

Once fitted, refill the cistern and confirm the water stops at the correct level below the overflow.

Step 7: 7️⃣ Replace the outlet seal or complete flush valve if water leaks into the pan

If water continues leaking from the cistern into the pan after seal replacement, the valve seat or outlet valve body may be damaged.

For accessible close-coupled cisterns, the repair may involve:

Removing the cistern lid
Draining the cistern
Disconnecting the inlet
Undoing cistern fixing bolts
Lifting the cistern clear
Replacing the full outlet valve and cistern-to-pan seals
Reinstalling and aligning the cistern

This is more involved than a simple seal change and can lead to leaks if done incorrectly. It also moves beyond basic troubleshooting into more formal plumbing repair work.

If you are unsure at this point, it is sensible to stop and book a licensed plumber.

Step 8: 8️⃣ Reassemble, test, and check water efficiency

Reinstall the cistern lid carefully and ensure the flush buttons move freely.

Run these final checks:

Flush full and half flush several times
Confirm the water stops filling at the correct level
Listen for any ongoing hiss after 1 to 2 minutes
Check for leaks at the 15 mm inlet connection
Confirm there is no trickle into the pan

If the toilet is older and parts are no longer reliable, replacement may be more cost-effective than repeated repairs. If you are replacing the entire toilet suite, choose a model with a strong WELS rating. In Australia, many efficient toilets are 4 Star WELS, commonly 4.5/3 L dual flush with an average flush of 3.3 L.

Common Mistakes to Avoid

1.Replacing the wrong part without first checking whether the leak is from the inlet valve or the outlet seal.
2.Setting the water level too high so it constantly spills into the overflow.
3.Overtightening plastic cistern nuts, which can crack fittings or distort seals.
4.Buying non-compatible or non-WaterMark-certified replacement parts.
5.Ignoring a leak at the wall stop tap, flexible hose, or pan base, which is not a simple cistern-running issue.

Pro Tips

💡 Take a photo of the cistern internals before disassembly so you can match parts and reassemble correctly.
💡 If the toilet runs only every few minutes, the outlet seal is more likely the issue than the inlet valve.
💡 Bring the old valve or seal to the plumbing supplier; brand and model matching saves time and avoids repeat visits.
💡 Clean scale from the valve seat and moving parts before fitting new seals, especially in hard-water areas.
💡 If your toilet is old, noisy, and inefficient, compare repair cost with upgrading to a 4 Star WELS toilet suite.

Recommended Tools

Adjustable spanner 250 mm — useful for isolation valves, cistern nuts, and supply fittings
Multigrip pliers — handy for loosening stubborn retaining nuts and holding fittings
Headlamp or compact torch — makes it much easier to inspect inside the cistern and behind the pan
Food colouring or cistern leak-detection tablets — fast way to confirm an outlet valve leak into the pan
Plumbing repair kit for your toilet brand — convenient if you want seals, buttons, and valve components in one pack

🔒 Licensing: Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials. For state-based requirements, check NSW Fair Trading, VIC VBA, QLD QBCC, or WA Building Commission.

Frequently asked questions

What causes an Australian toilet to run continuously?
A toilet runs continuously due to a degraded flush valve seating washer, an incorrectly adjusted float level, or a faulty inlet valve failing to shut off. If water spills into the internal overflow pipe, the inlet valve or float is faulty. If water seeps directly into the pan below the overflow line, the outlet seal requires replacement.
How do you test if a toilet cistern is leaking into the pan?
Place several drops of food colouring into the cistern water and leave it undisturbed for twenty minutes without flushing. If coloured water appears in the toilet bowl, the flush valve washer or seating seal is leaking. If the bowl water remains clear, the leak is likely caused by an overflowing inlet valve.
Can a homeowner legally replace a toilet inlet valve in Australia?
Homeowners can replace minor internal serviceable components like rubber washers or drop valves in most states, but replacing valves connected directly to mains water generally requires a licensed plumber under AS/NZS 3500.2. State regulators, such as the Victorian Building Authority and NSW Fair Trading, restrict unlicensed interference with pressurised drinking water connections.
What height should the water level be set to inside a cistern?
Set the resting cistern water level between 15 millimetres and 25 millimetres below the top rim of the overflow pipe. To lower the level, adjust the threaded adjustment rod on a modern float valve clockwise, or reposition the ratcheted float clip on standard Caroma, Fowler, or Fluidmaster assemblies.
Do toilet replacement parts need WaterMark certification in Australia?
All replacement toilet valves, cistern mechanisms, and flexi-connectors installed in Australia must carry valid WaterMark certification under the Plumbing Code of Australia. Installing non-certified fittings breaches National Construction Code Volume Three, invalidates home insurance policies, and risks premature failure due to incorrect pressure ratings.
How much water does a leaking toilet cistern waste per day?
A continuously running toilet wastes between 200 and 1,000 litres of potable water per day, depending on the severity of the leak. Undetected slow leaks through a degraded flush cone or outlet seal typically add hundreds of dollars to quarterly municipal council water utility bills.

Written by Pipey, the Plumbing specialist at VIC.Tools.