Skip to main content

How to use a drain camera to diagnose blocked drains

Diagnose blocked drains accurately with a drain camera. This guide covers essential techniques, tools, and Australian standards for plumbers to identify blockages, root intrusion, or pipe damage efficiently.

Skill level
Intermediate
Time
1-3 hours for a standard domestic diagnosis, longer where multiple junctions, heavy root intrusion, or collapsed lines are involved
Trade
Plumbing
Updated
28 November 2026

Tools you will need

  • Ridgid SeeSnake Mini - Drain Inspection Camera (with self-levelling head)
  • Ridgid NaviTrack Scout - Underground Pipe Locator
  • Milwaukee M18 FUEL High-Performance - Headlamp
  • Stanley FatMax 8m - Tape Measure
  • Selleys Trade - Marker Paint (Fluoro Orange)
  • Karcher HD 5/11 P - High-Pressure Cleaner (for pre-cleaning)
  • Drain Cleaning Cable Machine (e.g., Spartan 100)
  • Safety Glasses (AS/NZS 1337.1 certified)

🔧 Trade guide: using a drain camera to diagnose blocked drains accurately and efficiently

What is involved in using a drain camera for blocked drains?

Using a drain camera properly allows plumbers to confirm the cause, location, severity, and likely repair method for blocked drains without unnecessary excavation or guesswork. In Australian drainage work, camera inspection is commonly used on sanitary and stormwater lines from 40 mm fixture wastes through to 100 mm and 150 mm property drains, in conjunction with a sonde locator and, where required, jetting or mechanical cleaning equipment.

Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials. Inspection, testing, repair, and alteration of drainage systems must comply with the Plumbing Code of Australia (PCA) and relevant provisions of AS/NZS 3500, with licensing regulated by authorities such as NSW Fair Trading, VIC VBA, QLD QBCC, and the WA Building Commission.

What skill level is required to operate a drain camera effectively?

Intermediate — Estimated time: 1-3 hours for a standard domestic diagnosis, longer where multiple junctions, heavy root intrusion, or collapsed lines are involved

What essential tools are needed for a drain camera inspection?

Drain inspection camera with self-levelling head, suitable for 40 mm-150 mm lines
Camera reel/push rod, typically 20 m-60 m depending on residential or commercial work
Sonde locator/transmitter and receiver for tracing buried drains
CCTV monitor/recording unit with still image and video capture
Pipe skids/guides sized for 50 mm, 90 mm, 100 mm, and 150 mm pipelines
Access keys and hand tools for inspection openings, ORG caps, boundary trap caps, and maintenance shafts
High-pressure water jetter or sectional drum machine for pre-cleaning if the line is fully blocked
Measuring wheel or tape measure for above-ground reference checks
Marker paint, flags, or chalk for marking defect locations
Torch or headlamp for pits, underfloor areas, and low-light access points
Bucket, wet vac, or absorbent pads for spill control around openings
PPE: gloves, eye protection, waterproof boots, long sleeves, and hearing protection if jetting
Job tablet or inspection form for recording pipe material, defect location, invert direction, and recommendations

Materials Required

Cleaning rags and disinfectant wipes for camera head and cable hygiene
Replacement inspection opening caps, ORG caps, or trap caps if damaged during access
PVC or DWV lubricant approved for camera skid fitting where required
Marker paint or flags for surface marking of located defects
Temporary barriers/signage for work area control
Spare camera skids for 50 mm, 65 mm, 90 mm, 100 mm, and 150 mm pipework
Batteries/chargers for locator, monitor, and recording unit
USB drive, SD card, or cloud upload access for client reporting
Jetter nozzles or cutter heads if combining cleaning with inspection
Basic repair consumables if minor reinstatement is planned after diagnosis, such as rubber couplings, PVC fittings, and solvent cement suitable for DWV PVC

Safety Requirements

Confirm site hazards before opening any drain access point, including traffic, slips, contaminated water, and electrical risks near pump pits or external GPOs.
Treat all sanitary drainage as contaminated. Use gloves, eye protection, wash-down facilities, and contamination control for tools and hands.
Do not insert or retrieve camera equipment from live electrical pits, unverified confined spaces, or unstable excavations without appropriate controls.
If jetting or drain cleaning is required before camera work, isolate the work area and manage hose whip, splashback, and noise exposure.
Be cautious with hot discharge lines from commercial kitchens, laundries, and plant rooms.
Where the line may contain chemical waste, grease interceptor discharge, or industrial effluent, confirm compatibility before inserting the camera.
Never force the camera through a hard obstruction where a collapsed section is suspected, as this can damage the push rod or camera head and worsen the failure.
Gas work requires a separate gas fitter licence. If tracing combined service corridors or excavation zones, confirm gas service locations before digging.
🔒 Licensing: Drainage diagnosis, drain clearing, repair, and alteration in Australia must be carried out by appropriately licensed plumbing practitioners in accordance with the PCA and AS/NZS 3500, with state-based requirements set by NSW Fair Trading, VIC VBA, QLD QBCC, and the WA Building Commission.

Step-by-Step Guide

Step 1: 1️⃣ Assess the complaint and choose the best entry point

Start by confirming the reported symptoms: single fixture blockage, multiple fixture surcharge, gully overflow, ORG discharge, slow stormwater pits, or repeated backups after previous clearing. This tells you whether you are likely dealing with a branch drain issue, stack issue, graded drain problem, or downstream property drain obstruction.

Select the most suitable access point before uncoiling the camera. For internal sanitary drains this may be an inspection opening, boundary trap, ORG, stack access, or maintenance shaft. For stormwater, it may be a grated pit, charged line inspection point, or downstream pit. Choose an access point that allows you to inspect in the normal direction of flow wherever possible.

Match the camera head and skid to the pipe size and likely line condition. In residential work, common lines include 40 mm and 50 mm fixture wastes, 65 mm branch lines, and 90 mm-100 mm sanitary drains. Stormwater commonly includes 90 mm, 100 mm, and 150 mm PVC.

Step 2: 2️⃣ Pre-clean if the line is fully obstructed

A drain camera is a diagnostic tool, not a clearing tool. If the line is surcharged with water, full of paper, grease, or roots, perform enough cleaning first to establish visibility. Depending on the blockage type, use a jetter, eel, or cutter head to restore partial flow.

Do not over-clean before the first meaningful inspection if you are trying to preserve evidence for insurance, builder defect claims, or tenancy disputes. In those situations, take preliminary footage at the access point showing surcharge level, visible roots, or broken pipe edges before aggressive cleaning.

💡 For recurring sewer blockages, a quick pre-clean followed by a full CCTV run gives the best balance between visibility and accurate diagnosis. Root masses often hide cracked sockets, displaced junctions, or backfall until the line is reopened.

Step 3: 3️⃣ Set up the camera system correctly

Inspect the camera head lens, LEDs, spring, skid, and push rod for damage. Confirm the sonde is transmitting if your unit has an integrated locator head. Zero or note the reel metre counter before insertion so footage can be tied to measured location later.

Set the monitor to record video and stills with date, site address, and line reference if the unit supports it. On multi-line jobs, label each run clearly, for example: “Kitchen branch from IO”, “Sewer from boundary trap to main”, or “Stormwater south line from pit 2”.

Adjust brightness to suit the pipe material and water level. Overexposed LED settings in clean white PVC can wash out joints, while low light in vitrified clay or cast iron can hide cracks and corrosion.

Step 4: 4️⃣ Insert the camera with control, not force

Feed the camera into the line steadily while maintaining light forward pressure. Use skids in larger pipework so the lens stays centred and gives a reliable view of joints, grade, and internal wall condition. A self-levelling head is particularly useful for identifying backfall and standing water.

Advance slowly past bends, junctions, and offsets. If resistance is encountered, withdraw slightly, rotate the rod, and re-approach. Forcing the head through a tight bend, displaced joint, or root mass can damage the camera and create a false impression of line condition.

Pay close attention to changes in pipe material. Domestic lines may transition from PVC to earthenware, cast iron, or repaired sections with rubber couplings. These transitions are common defect points and should be filmed clearly.

Step 5: 5️⃣ Read the pipe condition systematically

As you advance, assess the line in a consistent sequence:

flow condition
pipe material
joint condition
alignment
grade
intrusions or deposits
signs of structural failure

Typical blockage causes include root intrusion at joints, grease accumulation, paper and sanitary product build-up, scale in older pipework, construction debris, displaced junctions, collapsed sections, and sagging sections holding water. In stormwater, look for siltation, leaf matter, gravel ingress, crushed pipe, and incorrect falls.

A full water line at the invert after cleaning can indicate partial obstruction, backfall, or downstream surcharge. A clear mirror-like water level across the bottom of the pipe over a long section often suggests a belly or low spot, especially in 100 mm PVC property drains.

Step 6: 6️⃣ Locate the defect from the surface

Once a defect is identified, stop the camera at the centre of the issue and activate the locator. Trace the sonde from ground level and mark the position with paint or a flag. Record both the reel distance and the surface position relative to fixed site features such as external walls, pits, fences, or inspection shafts.

Take at least one mark at the defect and one confirming mark at a nearby known point. This reduces the chance of error where multiple parallel services exist. In dense service zones, confirm depth if your locator provides this function, but treat depth readings as indicative rather than absolute.

💡 On repair jobs, accurate locating can be the difference between a targeted excavation and unnecessary trenching across paving, driveways, or landscaped areas.

Step 7: 7️⃣ Confirm upstream and downstream condition

Do not stop after finding the first problem. Continue the inspection to verify whether there are multiple defects, especially in older drains where root intrusion, poor grade, and joint separation often occur in the same line. If the camera cannot pass, inspect from the opposite end where possible.

Where access allows, run the camera both directions. This gives a better understanding of:

exact defect extent
proximity to junctions
whether the blockage is localised or system-wide
whether repair, reline, replacement, or maintenance cleaning is the best recommendation

For branch drains, confirm that upstream fixtures and branch entries are correctly connected and flowing. Misconnections and poorly executed renovation tie-ins are common causes of repeat blockages.

Step 8: 8️⃣ Capture evidence suitable for quotation and compliance records

Record clear still images and continuous video of each significant finding. At minimum, capture:

entry point used
pipe size and material if identifiable
measured distance to defect
the defect itself
locating mark reference
downstream or upstream continuation

Describe defects using precise trade terminology such as “root intrusion through socket joint at 11.6 m”, “displaced PVC coupling”, “standing water indicating probable backfall”, “earthenware fracture with soil ingress”, or “grease build-up reducing bore by approximately 60%”.

Where repairs are proposed, tie your recommendation back to compliance with the PCA and applicable sections of AS/NZS 3500 relating to drainage performance, access, and installation quality.

Step 9: 9️⃣ Interpret the findings and recommend the right remedy

Match the fault to the most suitable corrective action. Examples include:

grease or soft blockage: clean and review maintenance frequency
root intrusion at otherwise sound pipe: cut roots and schedule maintenance, or repair/reline affected section
displaced or broken pipe: excavate and replace affected length
long section of backfall: regrade and relay
repeated blockage in old earthenware: consider sectional replacement or full renewal depending on condition and client budget

Be clear where camera evidence supports only probable diagnosis rather than absolute confirmation. For example, a line full of water beyond an inaccessible bend may indicate downstream obstruction, but full confirmation may require secondary access or excavation.

💡 For insurance or body corporate work, provide a concise defect summary with video reference times, marked locations, and repair scope. This speeds up approval and reduces call-backs.

Step 10: 🔟 Clean down, restore access points, and issue the report

Withdraw the camera carefully, cleaning the push rod as it returns to the reel to reduce contamination and extend equipment life. Inspect the head and skid for wear or damage after the run. Replace and tighten all access caps, trap caps, and inspection covers so the system is left safe and sealed.

Provide the client or supervisor with a structured report including:

complaint received
access point used
line inspected and approximate size
blockage cause
defect location by metres and surface mark
recommended repair method
whether immediate action is required

If no clear defect is found, note operating condition at the time of inspection and any limitations such as heavy flow, inaccessible sections, submerged camera view, or inability to pass a junction.

Common Mistakes to Avoid

1.Using the camera before establishing the correct line and flow direction, resulting in inspection of the wrong branch or stormwater line.
2.Forcing the camera through a blockage or suspected collapse, which can damage expensive equipment and distort the diagnosis.
3.Failing to pre-clean sufficiently, leading to muddy, submerged footage that does not identify the true cause of the blockage.
4.Recording poor-quality footage without metre count, line description, or surface location, making the inspection useless for quoting or excavation.
5.Stopping at the first defect and missing additional issues downstream such as further roots, sagged sections, or broken junctions.

Pro Tips

Use the smallest practical camera head for branch drains, but fit the correct skid in larger lines so the image stays centred and joint condition is easier to read.
On recurring root intrusion jobs, inspect immediately after cutting and again after flushing. The first pass confirms obstruction; the second pass shows whether the host pipe is salvageable.
Mark defects against permanent site features and photograph the locator reading. This is especially useful where the excavation is to be done on a later date by another crew.
Keep a standard defect terminology list across your business so reports are consistent between plumbers, apprentices, and office staff.
If a domestic sewer repeatedly blocks after rain, inspect both sanitary and stormwater systems. Illegal cross-connections and surcharge conditions can mimic a simple blockage.

Recommended Tools

🔧 Recommended Tools

RIDGID SeeSnake Compact M40 or M40+ — strong all-round choice for residential and light commercial CCTV inspection with reliable image quality
Milwaukee M12 Pipeline Locator Kit or equivalent sonde locator — useful for accurate surface marking of buried defects
Spartan Tool Revolution M1 or similar compact drain camera — suitable for everyday service work on 50 mm-100 mm drains
General Pipe Cleaners Gen-Eye POD — portable option for service vehicles where space is limited
A quality self-levelling camera head skid kit — essential for clearer inspection in 90 mm, 100 mm, and 150 mm lines

Frequently asked questions

What is the primary benefit of using a drain camera for blocked drains?
The primary benefit of using a drain camera is to accurately diagnose the cause, location, and severity of a blocked drain without destructive excavation, saving time and reducing repair costs. This precision allows plumbers to determine the most effective repair method, such as hydro-jetting, pipe patching, or relining, ensuring targeted intervention.
What size pipes can typically be inspected with a standard drain camera in Australia?
Standard drain cameras in Australia are typically used to inspect pipe diameters ranging from 40 mm fixture wastes up to 150 mm property drains for both sanitary and stormwater lines. Specialised cameras exist for larger mains, but for domestic and light commercial applications, these sizes cover most common plumbing scenarios as per AS/NZS 3500.
How do I locate a blockage or pipe defect accurately using a drain camera?
To accurately locate a blockage or pipe defect, use a drain camera equipped with a built-in sonde (transmitter) in conjunction with a compatible locator device. As the camera's sonde passes the defect, the locator above ground will pinpoint its exact position and depth, allowing for precise marking with marker paint or flags.
What Australian standards and regulations apply to drain camera inspections?
Drain camera inspections in Australia must comply with the Plumbing Code of Australia (PCA) and relevant sections of AS/NZS 3500: Plumbing and Drainage. These standards outline requirements for drainage system design, installation, inspection, and repair, ensuring all work meets safety and performance criteria for Australian conditions.
What are the common signs of a collapsed drain that a camera inspection can identify?
Common signs of a collapsed drain identifiable by camera inspection include visible cracks, breaks, severe pipe deformation, or complete dislodgement of pipe sections, often accompanied by debris ingress or soil intrusion. The camera will reveal a distinct obstruction where the pipe integrity has failed, confirming the need for excavation and repair.
Can a drain camera be used to inspect stormwater drains as well as sanitary drains?
Yes, a drain camera is highly effective for inspecting both stormwater and sanitary drains, providing clear visual evidence of blockages, root intrusion, or structural defects in either system. The same equipment and diagnostic principles apply, allowing for comprehensive assessment of a property's entire drainage network.

Written by Pipey, the Plumbing specialist at VIC.Tools.