How to use a drain camera to inspect blocked pipes
Drain camera inspections are one of the most effective methods for diagnosing recurring blockages, locating pipe defects, confirming line condition, and identifying junctions, offsets, root ingress, or collapsed sections. Plumbing work in Australia must be performed by a licensed plumber. This guide
- Skill level
- Advanced
- Time
- 1–3 hours per inspection, depending on access, pipe length, blockage severity, and reporting requirements
- Trade
- Plumbing
- Updated
- 28 November 2026
Tools you will need
- Drain inspection camera system with self
- High
- Measuring wheel or tape measure for surface set
- PPE including gloves, eye protection, boots, high
🔧 Using a drain camera to inspect blocked pipes — professional trade guide for Australian plumbers
What is the primary purpose of using a drain camera for pipe inspections in Australia?
Drain camera inspections are one of the most effective methods for diagnosing recurring blockages, locating pipe defects, confirming line condition, and identifying junctions, offsets, root ingress, or collapsed sections. Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials.
For Australian trade professionals, drain CCTV work should be carried out in line with the PCA and relevant provisions of AS/NZS 3500, particularly where inspection outcomes inform repair, replacement, excavation, or compliance decisions. If inspection identifies gas-related risks or confined-space hazards, additional licensed or specialist controls may apply.
What skill level is required for drain camera inspections in Australia?
Advanced — Estimated time: 1–3 hours per inspection, depending on access, pipe length, blockage severity, and reporting requirements
What essential tools are required for a professional drain camera inspection in Australia?
Materials Required
Safety Requirements
Step-by-Step Guide
Step 1: Assess the job and confirm the drainage system layout
1️⃣ Review the service history
Establish whether the issue is a recurring blockage, slow drain, overflow, surcharge, odour complaint, or suspected structural failure. Ask which fixtures are affected and whether previous clearing has been temporary or ineffective.
Check available plans, as-builts, sewer service diagrams, and prior CCTV reports. Determine whether you are inspecting sanitary drainage, stormwater, trade waste, or a combined site issue.
💡 For repeat call-backs, camera work is most valuable after basic clearing because it confirms whether the underlying issue is roots, grade failure, a cracked junction, grease build-up, or a collapsed section rather than a simple obstruction.
Step 2: Select the correct access point
2️⃣ Choose the best entry location
Identify the most suitable inspection opening, boundary trap, overflow relief gully vicinity, upstream shaft, downstream pit, or maintenance opening. The best access point is usually one that allows inspection in the direction of flow and, if possible, back upstream as a secondary pass.
For internal branch lines, access may be through a fixture trap riser, floor waste branch, or dedicated inspection opening. For main drains and house sewers, common entry sizes are 100 mm or 150 mm.
Avoid forcing a large camera head into smaller branch lines. Match the camera head and rod stiffness to the pipe diameter and likely fitting configuration.
Step 3: Make the line safe and prepare the work area
3️⃣ Set up for safe inspection
Advise occupants or site personnel not to use affected fixtures during the inspection. Isolate the work zone with cones or barrier tape.
Open access points carefully in case the line is surcharged. If the pit or opening is full, remove standing water as required and clean the entry enough to avoid immediately fouling the camera lens.
If the area is enclosed, poorly ventilated, or pit-based, test atmosphere as required. Never assume a pit is safe because it is shallow.
⚠️ Safety
Step 4: Pre-clean the line if visibility will be compromised
4️⃣ Open and flush before CCTV if needed
If the line is fully blocked or heavily fouled with grease, paper, wipes, roots, or silt, conduct preliminary clearing using a drain machine or high-pressure jetter. The goal is not necessarily full restoration at this stage, but enough flow path to allow camera passage and meaningful footage.
For sanitary lines with grease or paper accumulation, jetting often provides better visual results than cable cleaning alone. For root masses in larger lines, mechanical opening may be needed before a second cleaning pass.
Do not issue defect conclusions from a camera pushed into opaque sludge or backed-up effluent without proper cleaning. Poor visibility produces poor diagnosis.
Step 5: Configure and test the camera system
5️⃣ Prepare the CCTV unit
Inspect the camera head, lens, skids, push rod, and monitor before insertion. Confirm the recording function works and the sonde is transmitting correctly.
Fit an appropriate skid if inspecting a larger diameter line. In 100 mm or 150 mm drains, a skid helps keep the lens centred and improves orientation and image quality.
Set the date, property details, and job reference in the recording system if your unit allows text overlay. This is important for traceability and reporting.
💡 A self-levelling head significantly improves interpretation of grade issues, junction direction, and waterline observations during reporting.
Step 6: Insert the camera and begin the inspection run
6️⃣ Feed the camera methodically
Introduce the camera slowly into the pipe while watching the monitor continuously. Advance in controlled increments rather than forcing the rod. Let the head navigate bends and junctions with steady pressure.
Call out and record meter marks, fitting changes, material transitions, and direction changes as you progress. Typical observations include:
If you lose orientation, withdraw slightly and re-approach. Excessive force can damage the camera head, push rod, or existing brittle pipework.
Step 7: Identify and interpret common defects
7️⃣ Diagnose what the camera is showing
Use the footage to determine whether the blockage is operational, structural, or installation-related. Common findings include:
Standing water does not automatically prove a major belly; it may reflect line loading, camera angle, or downstream restriction. Confirm by inspecting from the opposite direction where possible and by locating the exact section above ground.
💡 A recurring blockage at the same meter mark usually points to a fixed defect, not just poor user behaviour.
Step 8: Locate defects from the surface
8️⃣ Trace and mark the line accurately
Use the sonde locator to identify the camera head position from above ground. Mark defect locations with paint or chalk and record both depth and distance from the access point.
Take multiple locator readings if accuracy matters for excavation, especially near:
For commercial or strata work, produce a simple sketch showing access point, pipe run, defect marks, and depth. This reduces dispute and improves excavation efficiency.
Step 9: Inspect upstream and downstream as needed
9️⃣ Complete both directions where practical
A single inspection run may not reveal the full cause. After reaching the blockage, boundary connection, pit, or termination point, withdraw while observing additional details that may have been missed on insertion.
If possible, inspect from the opposite end as well. Dual-direction inspection is especially useful for:
This step often separates a quick service call from a high-value diagnostic job.
Step 10: Record evidence and prepare the report
🔟 Document the findings professionally
Capture stills and video of all significant defects, meter marks, and transitions. A professional report should include:
Recommended actions may include jet clean, root cut, sectional repair, patch relining, full excavation and replacement, additional inspection openings, or line regrade.
Reference compliance implications where relevant under the PCA and AS/NZS 3500, particularly if there is evidence of defective falls, illegal connections, damaged sanitary drainage, or non-compliant stormwater discharge arrangements.
Step 11: Clean down equipment and reinstate access points
1️⃣1️⃣ Finish the job properly
Withdraw the camera carefully, cleaning the rod progressively as it returns to the reel. Decontaminate the camera head, skids, and tools before packing away.
Re-fit inspection caps securely and replace damaged seals or caps where needed. Confirm the area is clean, safe, and left in serviceable condition.
Advise the client or site manager of immediate risks if you have found a collapsed line, active leakage, or conditions likely to cause imminent surcharge.
Common Mistakes to Avoid
Pro Tips
Recommended Tools
🔒 Licensing
Plumbing work in Australia must be performed by a licensed plumber. This guide explains the process and helps you select the right tools and materials. Licensing requirements vary by state, including NSW Fair Trading, VIC VBA, QLD QBCC, and WA Building Commission. Gas work requires separate gas fitter licence.
Frequently asked questions
- What is involved in use a drain camera to inspect blocked pipes?
- Drain camera inspections are one of the most effective methods for diagnosing recurring blockages, locating pipe defects, confirming line condition, and identifying junctions, offsets, root ingress, or collapsed sections. Plumbing work in Australia must be performed by a licensed plumber. This guide
- What skill level do I need for use a drain camera to inspect blocked pipes?
- Advanced — Estimated time: 1–3 hours per inspection, depending on access, pipe length, blockage severity, and reporting requirements
- What are common mistakes when use a drain camera to inspect blocked pipes?
- 1. Forcing the camera through bends, junctions, or obstructions and damaging the head or worsening pipe defects. 2. Inspecting a heavily fouled line without pre-cleaning, resulting in unusable footage and incorrect diagnosis. 3. Failing to use the locator accurately, leading to unnecessary excavation in the wrong position. 4. Assuming standing water always means a belly, without checking downstrea
- What tools do I need for use a drain camera to inspect blocked pipes?
- This guide includes a comprehensive tools list. Key plumbing tools are detailed in the Tools Required section.
- What is the Australian standard for plumbing and drainage inspections?
- The primary Australian standard for plumbing and drainage is AS/NZS 3500:2021. This standard outlines requirements for design, installation, and inspection of plumbing and drainage systems, including considerations for identifying defects. For tradies, adherence to AS/NZS 3500 is crucial for compliance and ensuring public health and safety.
- When should a drain camera be used for a blocked pipe?
- A drain camera should be used when recurring blockages occur, to accurately diagnose the cause, or to confirm the integrity of drainage lines. It is essential for locating pipe defects, identifying root ingress, collapsed sections, or offsets that traditional methods cannot detect. This ensures targeted and cost-effective repairs.
- What PPE is required for drain camera inspections in Australia?
- Essential PPE for drain camera inspections in Australia includes safety glasses or goggles, chemical-resistant gloves (e.g., nitrile), steel-capped boots, and high-visibility clothing. Depending on the environment, hearing protection, respirators for confined spaces, and hard hats may also be required. According to SafeWork Australia, a risk assessment should always guide PPE selection.
- How deep can a typical drain camera locate a pipe in Australia?
- Most professional drain camera systems with integrated sondes and compatible locators can accurately trace and locate pipes up to 3-5 metres deep in typical Australian soil conditions. Factors like soil composition, pipe material (non-metallic pipes are easier), and interference from metallic structures can affect maximum depth and accuracy. Always calibrate your locator on-site.
Written by Pipey, the Plumbing specialist at VIC.Tools.