Skip to main content

How to prime a pool pump after it loses suction

Learn how to prime a pool pump in Australia after losing suction. Follow step-by-step instructions, air leak diagnostics, and pump lid maintenance tips.

Quick answer

To prime a pool pump, isolate the power, remove the clear strainer lid, and manually fill the basket pot to the brim with water using a hose or bucket. Reseat the lubricated lid firmly and turn the motor on; water circulation should re-establish within 60 to 90 seconds.

Skill level
Beginner to Intermediate
Time
15–45 minutes, depending on how easily the pump takes prime and whether you need to inspect for air leaks or blockages.
Trade
Pool & Irrigation
Updated
28 November 2026

Tools you will need

  • Nylex Never Kink 18mm x 30m - Heavy Duty Garden Hose
  • Knipex Cobra 250mm - Quick-Set Water Pump Pliers
  • Waterco Lid Opener Tool - Universal Pump Lid Spanner
  • Loctite LB 8801 / Boss - Silicone O-Ring Lubricant
  • Ledlenser P7 Core - Handheld LED Inspection Torch
  • Bostik Titan Multi-Purpose - 10L Trade Bucket

What does it mean to prime a pool pump in Australia?

Priming a pool pump means filling the pump housing and suction line with water so the pump can create enough vacuum to start circulating again. In Australian backyards, loss of prime commonly happens after cleaning the pump basket, when the pool water level drops below the skimmer, after a power outage, or if there is a small air leak on the suction side.

What skill level is required to re-prime a pool pump?

Beginner to Intermediate — Most homeowners can re-prime a pool pump safely with basic tools, provided there is no electrical fault or major plumbing leak. The job becomes intermediate if you need to track down suction leaks, faulty O-rings or blocked pipework.

How long does it take to prime a pool pump?

15–45 minutes, depending on how easily the pump takes prime and whether you need to inspect for air leaks or blockages.

What tools are needed to prime a pool pump?

Garden hose
Bucket or watering can
Clean rag or cloth
Silicone-based pool O-ring lubricant
Flathead screwdriver or suitable lid key/clamp tool
Adjustable pliers or multigrips for stubborn unions
Pool-safe replacement O-ring or lid gasket if required
Torch for checking leaks and cracks
Skimmer plate or vacuum plate if applicable
PPE: safety glasses and gloves

What are the steps to prime a pool pump safely?

1.Switch off power and isolate the equipment — Turn the pool pump off at the controller and, ideally, at the power point or isolator as well. Never open the pump lid while the system is running. If the pump is hardwired, use the local isolator only—do not remove covers or attempt electrical repairs unless you are a licensed electrician, in line with Australian requirements.
2.Check the pool water level first — Make sure the pool water level is roughly halfway up the skimmer opening or slightly higher. If the water level is too low, the skimmer will draw air instead of water and the pump will not prime properly. Top up the pool with a hose if needed before doing anything else.
3.Set valves for the easiest suction path — If your system has multiple suction lines, such as skimmer, main drain or vacuum line, set the valves so the pump is drawing from the strongest and shortest line first—usually the skimmer or main drain. If there is a vacuum plate fitted in the skimmer, make sure it is seated properly and not sucking air.
4.Inspect the pump lid and basket area — Open the pump lid and remove the basket. Empty any leaves and debris. Check that the basket is seated correctly and has no cracks. Clean the lid O-ring or gasket and the sealing surface with a rag. If the O-ring is dry, flattened or nicked, it can let air in and stop priming.
5.Lubricate and inspect the lid O-ring — Apply a light film of silicone-based lubricant to the O-ring. Do not use petroleum grease, as it can damage rubber components. Refit the O-ring neatly into its groove. Australian pump brands such as Davey, Onga, AstralPool, Waterco and Zodiac all rely on a good lid seal for reliable priming.
6.Fill the pump pot completely with water — Using a garden hose or bucket, fill the pump housing/pump pot right to the top with clean pool water. The goal is to remove as much air as possible. If the water level drops quickly in the housing, that can indicate water draining back due to an air leak, a suction-side leak, or a faulty non-return/check valve if one is installed.
7.Refit the basket and secure the lid firmly — Place the basket back in position, then refit the lid and tighten it evenly. It needs to be snug and airtight, but do not overtighten to the point of cracking the lid. If your model uses a clamp ring, make sure it is seated evenly all the way around.
8.Open any air relief on the filter — If your filter has a manual air bleeder, usually on top of the filter tank, open it slightly before starting the pump. This allows trapped air to escape as water begins filling the filter. On cartridge filters and some media filters, this step helps the system prime faster.
9.Start the pump and watch the clear lid — Turn the pump back on and immediately observe the pump pot through the clear lid. Within 30 seconds to about 2 minutes, you should see the housing fill with water and the air bubbles reduce. Once a steady stream of water comes from the filter air relief, close the relief valve.
10.Let the pump run for 2–3 minutes to stabilise — A successfully primed pump will sound smoother and more consistent, and the water in the lid area should remain mostly full, with only a small air bubble at most. Return jets in the pool should have strong flow, and the filter pressure gauge should rise to its normal operating range.
11.If it does not prime, repeat using a hose-fed assist — Turn the pump off again. Refill the pump pot fully with water. If needed, place a garden hose into the skimmer box for a few minutes to help flood the suction line, especially after the line has drained back. Then restart the pump. Sometimes a pump that has fully lost water needs two or three attempts.
12.Check for common suction-side air leaks — If the pump still struggles, inspect the following:
Pump lid not sealed properly
Damaged lid O-ring
Loose pump unions on the suction side
Cracked pipe near the pump
Drain plugs on the pump housing not sealed
Skimmer weir door stuck shut
Skimmer basket blocked
Low pool water level
Vacuum hose or vacuum plate drawing air

Even a small air leak before the pump can stop proper prime.

13.Inspect the filter and valve position — Confirm the multiport valve, if fitted, is set correctly to Filter and not Closed. Never change a multiport setting with the pump running. If the filter is heavily blocked, backwash a sand or glass media filter, or clean the cartridge filter, because excessive restriction can make starting circulation harder.
14.Check for blockages in the skimmer or suction line — Remove and clean the skimmer basket. If you suspect a blockage, use the garden hose to flush from the pump side or from the skimmer side where possible. Debris such as gum leaves, palm seeds and small twigs are common in Australian pool plumbing and can cause partial suction loss.
15.Look for signs of a failed non-return valve or worn pump seal — If the pump primes but loses it again after switching off, water may be draining back to the pool. A faulty check valve, leaking union, or suction-side air leak is often the culprit. If you see persistent bubbles in the pump lid or from the return jets even after priming, there is usually still air entering the system somewhere.
16.Know when to stop and call a professional — If the motor hums but does not spin, the pump trips the breaker/RCD, there is a burning smell, water is leaking from the motor area, or the pump will not prime after basic checks, contact a pool technician or licensed electrician. In Australia, electrical diagnosis and repair must be carried out by a licensed trade professional.

Safety Notes

Always switch off power before opening the pump lid, moving valves, or loosening unions.
Never run a pool pump dry for more than about 30–60 seconds at a time, as this can damage seals, impellers and pump housings.
Do not change a multiport valve position while the pump is operating.
Keep hands clear of moving parts and avoid splashing water near electrical connections or timers.
If the pump is hardwired, do not open electrical covers or attempt capacitor/motor repairs yourself—use a licensed electrician.
Release filter air carefully, as trapped air under pressure can discharge suddenly.

Pro Tips

Keep the pool water level midway up the skimmer opening during summer; evaporation in Australia can be enough to break prime surprisingly quickly.
A small dab of silicone O-ring lube on the pump lid seal every few months helps prevent nuisance air leaks.
If your pump repeatedly loses prime overnight, mark the water level in the pump pot after shutdown and check whether it drains back.
Take a photo of your valve positions when the system is working properly so you can reset them quickly after cleaning or maintenance.
If you have a variable-speed pump, start on a higher speed for priming, then reduce to normal filtration speed once circulation is established.
Replacement lid O-rings and drain plug seals are inexpensive—typically around $10–$35 AUD—and are often worth replacing before chasing bigger faults.

Common Mistakes to Avoid

Trying to prime the pump while the pool water level is below the skimmer.
Forgetting to fill the pump pot completely with water before restarting.
Overtightening the clear lid and cracking it, especially on older pumps.
Using petroleum grease instead of silicone lubricant on O-rings.
Ignoring a worn lid seal or loose suction union because the leak is “only small”.
Leaving the multiport valve on the wrong setting after backwashing.
Running the pump dry for several minutes hoping it will “pick up”.
Assuming the issue is the motor when the real problem is usually air entering on the suction side.
Cleaning the basket but not checking the skimmer basket, weir door and vacuum plate for air entry.
Attempting DIY electrical repairs instead of calling a licensed Australian professional.

Frequently asked questions

How do you prime a pool pump that has lost suction?
To prime a pool pump, turn off power at the isolator, set the multiport valve to recirculate, remove the strainer lid, and fill the basket housing completely with water using a hose. Refit the lubricated lid securely, then start the pump. Water should begin pulling through within 30 to 60 seconds.
Why does my pool pump keep losing prime when turned off?
A pool pump loses prime when turned off because air enters the suction plumbing, breaking the hydraulic vacuum. The most common cause in Australia is a degraded lid O-ring, followed by loose union fittings, a leaking check valve, or cracked PVC pipes between the skimmer box and pump.
How long should it take for a pool pump to prime?
A healthy pool pump should catch prime within 30 to 90 seconds under normal Australian operating conditions. If the pump is located more than one metre above water level or has long pipe runs, it may take up to three minutes. Never run it dry past three minutes to prevent mechanical seal damage.
Can you use Vaseline on pool pump O-rings?
No, you must never use Vaseline or petroleum jelly on pool pump O-rings because petroleum degrades nitrile and neoprene rubber, causing swelling and permanent air leaks. Australian pool manufacturers like AstralPool, Waterco, and Onga mandate non-petroleum, 100% silicone or PTFE lubricants such as Boss or Lube-Tube.
How do you detect an air leak on the suction side of a pool pump?
To locate a suction air leak, run the pump and drape running water from a garden hose over the lid, drain plugs, and pipe unions one by one. If bubbles clear in the pump lid window while watering a joint, that fitting is drawing air and requires resealing or a new O-ring.
What electrical safety rules apply when maintaining an Australian pool pump?
All pool pump maintenance must comply with AS/NZS 3000:2018 Wiring Rules, requiring equipment to run on an RCD-protected circuit. Always isolate power at the switchboard or weatherproof outlet before opening the pump housing. Any hardwired pump replacements or motor repairs require a licensed Australian electrician.

Written by Poolie, the Pool & Irrigation specialist at VIC.Tools.