How to Install a USB Power Point
Learn how to install a USB power point safely in Australia. Step-by-step guidance on AS/NZS 3000 compliance, isolation, wiring, and testing procedures.
Quick answer
To install a USB power point in Australia, isolate the circuit at the main switchboard and verify with a calibrated voltage tester. Terminate the brown Active, blue Neutral, and green/yellow Earth cables into their corresponding terminals per AS/NZS 3000. All fixed electrical work must be certified by a licensed electrician.
- Skill level
- Beginner
- Time
- 1-2 hours
- Trade
- Electrical
- Updated
- 28 November 2026
Tools you will need
- Fluke T6-1000 - Electrical Voltage Tester
- Wiha SoftFinish 1000V - Insulated VDE Screwdriver Set
- Knipex 13 86 200 - Electrical Installation Pliers
- Megger MIT230 - Insulation Resistance Tester
- Clipsal Iconic 3042USB2 - Double Power Point with Integrated USB
- Milwaukee 2-in-1 Compact - Cable Stripper
What is a USB power point and why install one?
This guide outlines the process for installing a USB power point, replacing an existing standard power point. This upgrade provides convenient charging solutions for mobile devices directly from a wall outlet, eliminating the need for bulky adapters.
What skill level is required to install a USB power point in Australia?
Beginner — Estimated time: 1-2 hours
What specific tools are required for USB power point installation in Australia?
Voltage Tester/Multimeter: Essential for verifying circuits are dead. A non-contact voltage tester is also useful for initial checks. Insulated Screwdrivers: Flathead (various sizes) and Phillips head (PH1, PH2) for terminal screws and cover plates. Ensure they are rated for 1000V. Wire Strippers: For safely removing insulation from conductors (1.5mm, 2.5mm capacity). Side Cutters/Diagonal Pliers: For cutting wires. Small Spirit Level: For ensuring the new power point is installed straight. Pencil: For marking. Headlamp/Torch: For improved visibility in dimly lit areas. Insulation Resistance Tester (Megger): (Optional, for licensed electricians) To verify insulation integrity after installation.What materials are needed for a compliant USB power point installation?
USB Power Point: Choose a reputable brand (e.g., Clipsal, HPM, Legrand) with appropriate USB-A and/or USB-C ports and a minimum 2.1A output per port for efficient charging. Ensure it is Australian Standards compliant (AS/NZS 3112). New Mounting Block/Wall Box: (If existing is damaged or unsuitable) To ensure secure mounting. Electrical Tape: For securing connections if required, though not typically needed for modern terminals. Cleaning Cloth: For wiping down the area.What are the critical safety requirements for electrical work in Australia?
Electrical work in Australia must be performed by a licensed electrician. This guide is for understanding the process and selecting the right tools and materials. ALWAYS ISOLATE POWER: Before commencing any work, the circuit supplying the power point MUST be isolated at the main switchboard. Turn off the main switch and the specific circuit breaker/fuse for the power point. LOCK-OUT/TAG-OUT: For licensed electricians, apply a lock-out/tag-out device to the main switchboard to prevent accidental re-energisation. For homeowners, place a clear warning sign on the switchboard. VERIFY DEAD CIRCUIT: Use a voltage tester or multimeter to confirm that the circuit is completely de-energised at the power point terminals before touching any wires. PERSONAL PROTECTIVE EQUIPMENT (PPE): Wear appropriate PPE, including safety glasses and insulated gloves (if working near live parts, though this should be avoided). AS/NZS 3000 WIRING RULES: All electrical installations must comply with AS/NZS 3000:2018 (Wiring Rules) and relevant state/territory regulations (e.g., NSW Fair Trading, VIC ESV, QLD ESO, WA EnergySafety). EARTHING: Ensure all metallic parts are correctly earthed.Step-by-Step Guide
Step 1: Isolate Power at the Switchboard
Locate your main switchboard. Identify the circuit breaker or fuse that supplies power to the power point you intend to replace. Turn off the main switch first, then turn off the specific circuit breaker/fuse. Place a clear warning sign on the switchboard stating "DO NOT OPERATE - ELECTRICAL WORK IN PROGRESS."
Step 2: Verify Circuit is Dead
Return to the power point. Using your non-contact voltage tester, wave it near the power point to check for any residual voltage. Then, carefully remove the cover plate screws and the power point from the wall box. With your insulated screwdriver, carefully loosen the terminal screws holding the wires. Use your voltage tester or multimeter to test between Active and Neutral, Active and Earth, and Neutral and Earth terminals to absolutely confirm there is no voltage present. DO NOT PROCEED UNTIL YOU ARE CERTAIN THE CIRCUIT IS DEAD.
Step 3: Disconnect Existing Power Point
Once verified dead, carefully disconnect the wires from the existing power point. Note the colour coding:
Active (Live): Brown or Red (older installations) Neutral: Blue or Black (older installations) Earth: Green and Yellow (or Green in older installations)Pay close attention to which wire goes into which terminal (A, N, E). It's good practice to take a photo before disconnecting.
Step 4: Prepare Wires for New USB Power Point
Inspect the existing wires. If the insulation is damaged or the copper is corroded, carefully trim back the wire and re-strip a fresh section of insulation (approximately 10-12mm, as per the new power point's terminal strip length guide). Ensure there are no stray copper strands that could cause a short circuit. For 2.5mm TPS cable, ensure the conductor is fully inserted into the terminal.
Step 5: Connect New USB Power Point
Connect the wires to the corresponding terminals on the new USB power point:
Active (Brown/Red): Connect to the 'A' or 'L' terminal. Neutral (Blue/Black): Connect to the 'N' terminal. Earth (Green/Yellow): Connect to the 'E' or Earth symbol terminal.Ensure all connections are tight and secure. Give each wire a gentle tug to confirm it's firmly seated in the terminal. No copper strands should be visible outside the terminal.
Step 6: Mount the New USB Power Point
Carefully fold the wires back into the wall box, ensuring they are not pinched or stressed. Position the new USB power point into the wall box. Use a small spirit level to ensure it is perfectly straight. Secure the power point to the wall box using the provided mounting screws. Do not overtighten.
Step 7: Install Cover Plate
Attach the decorative cover plate to the USB power point, securing it with its retaining screws.
Step 8: Restore Power and Test
Return to the main switchboard. Remove your warning sign and lock-out/tag-out device (if used). First, turn on the specific circuit breaker/fuse for the power point. Then, turn on the main switch. Return to the newly installed USB power point. Plug in a device to the standard power outlet to ensure it works. Then, plug in a USB device (e.g., phone) to the USB ports to confirm it is charging correctly.
Common Mistakes to Avoid
Pro Tips
Take Photos: Before disconnecting anything, take clear photos of the existing wiring configuration. This serves as a valuable reference. Check Terminal Markings: Always refer to the 'A', 'N', 'E' or 'L', 'N', Earth symbol markings on the new power point, as they can vary slightly between brands. Quality Matters: Invest in a reputable brand of USB power point. Cheaper alternatives may have lower quality components or slower charging speeds. Consider Future Needs: If you have many USB-C devices, choose a power point with USB-C ports or a combination. RCD Protection: Ensure the circuit is protected by a Residual Current Device (RCD) at the switchboard. This is a mandatory safety requirement for all new power point circuits and highly recommended for existing ones.Recommended Tools
Fluke T150 Voltage/Continuity Tester: A robust and reliable tester for verifying dead circuits. Knipex 13 86 200 Pliers for Electrical Installation: Multi-functional pliers that can cut, strip, and crimp, reducing tool changes. Wera Kraftform Kompakt VDE 16 Slim 1 Screwdriver Set: Insulated screwdrivers with slim blades for accessing recessed terminals. Clipsal Iconic USB Power Point: A popular and reliable choice in Australia, known for its modular design and quality. HPM Excel Life USB Charger Powerpoint: Another excellent Australian compliant option with good charging capabilities.Frequently asked questions
- Can I legally install a USB power point myself in Australia?
- No, you cannot legally replace or install a standard power point with a USB power point yourself in Australia. Under Australian electrical safety legislation and AS/NZS 3000, fixed electrical wiring work must be performed by a licensed electrical contractor. Doing it unlicensed carries severe statutory fines and voids your home insurance policy.
- What is the wiring colour code for an Australian USB power point?
- Australian power points use standardised wiring colours: Active is brown (or red in older installations), Neutral is blue (or black in older wiring), and Earth is green/yellow. Always verify polarity with a multimeter rather than relying solely on sheath colour, especially when dealing with older, non-compliant Australian residential wiring circuits.
- Do USB power points draw continuous standby power?
- Most quality USB power points draw a negligible standby parasitic current of less than 0.1 watts when not in use. Premium brands like Clipsal and Hager feature smart internal switching that completely isolates the USB transformer module until a charging cable is physically plugged into the port, minimising unnecessary phantom energy consumption.
- Why is my new USB power point not charging fast?
- Slow charging usually results from inadequate output wattage or sharing amperage across dual ports. Standard budget outlets deliver 2.1 amps across both ports, whereas modern USB-C fast charging requires dedicated 30W Power Delivery (PD) protocols. Upgrading to a Clipsal Iconic with integrated 30W USB-C PD ensures your device charges at maximum speed.
- What Australian standards apply to USB power points?
- USB power points installed in Australia must comply with AS/NZS 3112 for standard socket outlets and AS/NZS 62368.1 for electrical equipment and USB power safety. The entire installation process must strictly adhere to AS/NZS 3000:2018 (the Australian/New Zealand Wiring Rules), ensuring mandatory RCD circuit breaker protection is active on the circuit.
Written by Sparky, the Electrical specialist at VIC.Tools.