How to reset a solar inverter after a power outage

Learn how to reset a solar inverter after a power outage safely. Follow standard Australian shutdown procedures to clear fault codes and restore solar power.

Quick answer

To reset a solar inverter, turn off the AC solar supply main switch, turn off the inverter AC isolator, and switch off the DC isolator. Wait five minutes to discharge stored energy. Reverse the steps to restart: switch on the DC isolator first, followed by all AC switches.

Skill level
Beginner
Time
15-30 minutes
Trade
Electrical
Updated
29 November 2026

Tools you will need

  • Fluke 117 True-RMS - Digital Multimeter CAT III 600V
  • Klein Tools NCVT-3P - Dual Range Non-Contact Voltage Tester CAT IV 1000V
  • Fronius Primo / Symo - Inverter Operating Manual
  • SMA Sunny Boy - System Quick Reference Guide
  • Sungrow SG Series - User Manual & iSolarCloud App
  • Cabac K11 - Electrical Switchboard Meter Box Key

⚡ How to reset a solar inverter after a power outage — safe Australian homeowner guide

What is involved in resetting a solar inverter after a power outage?

After a blackout or grid disturbance, most grid-connected solar inverters in Australia will shut down automatically and then attempt to reconnect once mains power is stable again. In many cases, no manual reset is needed — but if the inverter stays in fault mode, this guide explains the safe homeowner checks and restart sequence to try before calling your installer or a licensed electrician.

Electrical work in Australia must be performed by a licensed electrician. This guide is for understanding the process and selecting the right tools and materials. For grid-connected solar systems, the relevant requirements commonly include AS/NZS 3000, AS/NZS 4777.1, AS/NZS 4777.2, and AS/NZS 5033.

What skill level is required to reset a solar inverter?

Beginner — Estimated time: 15-30 minutes

What tools are required to safely reset a solar inverter?

Torch or headlamp for reading inverter and switchboard labels clearly
Smartphone or tablet with the inverter manufacturer app installed
Examples: Fronius Solar.web, Sungrow iSolarCloud, GoodWe SEMS, SolarEdge app
Access to the inverter user manual or quick-start guide
Pen and notebook, or phone camera, to record fault codes and indicator lights
Lockable warning tag or “Do Not Operate” tag if the system needs to remain isolated pending service
CAT III 600V digital multimeter — licensed electrician use only
CAT III 1000V non-contact voltage indicator — screening tool only, not a substitute for proving de-energised

What materials are needed for a solar inverter reset?

No replacement parts are normally required for a standard reset
Manufacturer login details or installer handover documents
Dry cloth to wipe dust from the display screen only
Temporary isolation tag if the inverter is left switched off awaiting service
If damaged wiring is suspected, do not attempt repair — common inverter supply cabling such as 2.5mm², 4mm², or 6mm² TPS must only be assessed and replaced by a licensed electrician

Safety Requirements

⚠️ Electrical work in Australia must be performed by a licensed electrician. This guide is for understanding the process and selecting the right tools and materials.
⚠️ Only use user-accessible, clearly labelled switches and isolators in accordance with the inverter manual.
⚠️ Do not remove covers from the inverter, switchboard, battery system, meter panel, or any rooftop equipment.
⚠️ Solar DC circuits can remain energised in daylight even when the mains supply is off.
⚠️ If there is any sign of burning smell, melted plastic, buzzing, arcing, water ingress, corrosion, storm damage, or cracked isolators, stop immediately and call a licensed electrician or your solar installer.
⚠️ Do not touch rooftop DC isolators, PV plugs, or wiring. Roof access and solar repairs are not DIY work.
⚠️ If the inverter or switchboard is wet after rain, flooding, or fire-fighting water, do not reset it until inspected.
⚠️ If a battery system is installed, follow the manufacturer’s shutdown/start-up procedure exactly. Hybrid and backup systems may have additional battery isolators and EPS/backup circuits.
⚠️ For any fault investigation beyond a basic user reset, licensed electricians should isolate correctly and follow lock-out/tag-out (LOTO) procedures before testing.
🔒 Licensing: In Australia, electrical installation and repair work must be carried out by a licensed electrician. Check your state regulator if you need to verify a contractor: NSW Fair Trading, VIC Energy Safe Victoria (ESV), QLD Electrical Safety Office (ESO), WA EnergySafety. Equivalent regulators apply in SA, TAS, ACT, and NT.

Step-by-Step Guide

Step 1: 1️⃣ Check whether the inverter actually needs a reset

After a blackout, a solar inverter usually shuts down as a safety function called anti-islanding. This is normal and required for grid-connected systems.

First, confirm that mains power has returned to the property:

Check if lights and general power are back on
Confirm neighbouring homes are also restored if possible
Check your switchboard for any tripped breakers or safety switches

If the house still has no mains power, the inverter will usually remain off or in standby. In that case, a reset will not solve the problem.

💡 Many inverters wait for the grid to stabilise before reconnecting. This delay is commonly between 60 and 300 seconds, depending on the model and settings under AS/NZS 4777.2 compliance.

Step 2: 2️⃣ Identify the type of solar system you have

Before touching any switches, work out what equipment is installed:

String inverter system: one main inverter mounted on a wall, usually in the garage, outside wall, or near the meter
Hybrid inverter system: inverter plus battery equipment and possibly backup circuits
Microinverter system: no large central inverter; each panel has electronics on the roof, and you may only have a gateway/controller such as an Envoy

If you have a microinverter system, there may be no manual inverter reset at all. In that case, check the monitoring gateway, internet connection, and switchboard solar supply breaker first.

If you have a battery or backup supply, be extra cautious. Some hybrid systems keep essential circuits energised during outages.

Step 3: 3️⃣ Read the inverter screen, lights, or app before switching anything

Check the inverter display or app for:

Fault code or warning message
Grid fault, overvoltage, undervoltage, frequency fault, insulation fault, relay check, or DC error
Status such as “Waiting”, “Standby”, “Checking grid”, “Normal”, or “Fault”

Take a photo of the screen and any error code before resetting. This helps your installer diagnose the issue if the fault returns.

Common post-blackout messages that may clear on their own include:

Grid over/under voltage
Grid frequency error
Mains loss
Reconnect countdown
Relay self-check

If the inverter says “Waiting for grid” or shows a countdown, let it finish first. Do not interrupt the normal reconnect cycle unless the manual specifically directs a reset.

Step 4: 4️⃣ Try a soft reset first if the model allows it

Some brands allow a simple user-level restart through:

The inverter touchscreen/menu
A restart button
The mobile app or web portal

If your model has a soft reset option:

1.Follow the exact manufacturer instructions
2.Confirm the command has been accepted
3.Wait for the inverter to reboot and begin its normal grid-check sequence

Do not guess your way through hidden installer menus. If the app asks for installer credentials or advanced settings, stop there.

💡 A soft reset is usually safer and faster than a full power-down, especially on newer Fronius, Sungrow, GoodWe, SMA, and SolarEdge systems.

Step 5: 5️⃣ If needed, perform a full shutdown in the correct order

Only do this if:

The inverter manual permits a user shutdown/start-up
The equipment is dry and undamaged
All switches are clearly labelled and accessible from ground level

A common shutdown sequence for many string inverters is:

1.Turn OFF the AC solar supply main switch at the switchboard if it is labelled for the inverter
2.Turn OFF the inverter’s AC isolator if a separate local AC isolator is installed
3.Turn OFF the inverter’s DC isolator if the manual identifies it as user-operable
4.Wait at least 5 minutes for the inverter capacitors and internal electronics to discharge

Some systems have only one AC switch and one DC switch. Others may label the AC side as “Solar Supply Main Switch” and the DC side as “PV Array DC Isolator”.

Do not operate any rooftop isolator. Do not unplug DC connectors. Do not open the inverter enclosure.

Step 6: 6️⃣ Restart in the correct order

For many Australian string inverter systems, the usual restart sequence is:

1.Turn ON the DC isolator first
2.Wait for the inverter display to power up and begin booting
3.Turn ON the local AC isolator if fitted
4.Turn ON the AC solar supply main switch at the switchboard

The inverter should now run through:

Internal checks
Grid voltage/frequency verification
Mandatory reconnect delay
Export/generation start-up

This process can take several minutes. Some inverters will show “Starting”, “Checking”, or a countdown timer before producing power.

💡 If the sun is low, heavily overcast, or it is late afternoon, the inverter may power up normally but still show little or no generation. That does not always mean the reset failed.

Step 7: 7️⃣ Confirm the system has come back online

Once the inverter has restarted:

Check the status is Normal, Running, or Generating
Confirm the app shows live PV production
Look for a solar generation reading in kW
Check your switchboard has no re-tripped breakers or RCDs
If you have a smart meter or home energy monitor, confirm solar export/import looks normal

A healthy restart usually shows:

Green or normal status LED
No active fault code
Gradual rise in generation depending on sunlight
App or portal data resuming within a few minutes

If the inverter repeatedly boots, trips, or falls back into fault mode, stop trying to reset it.

Step 8: 8️⃣ Know when to stop and call a professional

Call your solar installer or a licensed electrician if:

The same fault returns immediately after reset
The inverter shows isolation fault, arc fault, relay fault, RISO fault, or persistent DC fault
The solar circuit breaker or main switch keeps tripping
There is visible damage, water ingress, insects inside the unit, or burnt smell
The inverter display is blank even with confirmed AC and DC supply
A battery system shows alarms or will not reconnect
Grid voltage faults occur frequently after outages

If the issue appears to be a network supply problem, your installer may also advise contacting your DNSP or electricity retailer.

Common Mistakes to Avoid

1.Resetting the inverter before mains power is fully restored and stable.
2.Interrupting the inverter during its normal reconnect countdown and assuming it is faulty.
3.Switching AC and DC in the wrong order, or guessing the sequence instead of checking the manual.
4.Touching rooftop isolators, opening covers, or unplugging solar DC connectors.
5.Ignoring signs of damage such as heat marks, cracks, moisture, corrosion, or repeated breaker trips.

Pro Tips

💡 Most post-blackout inverter issues resolve themselves within a few minutes. Always wait through the full reconnect delay before doing anything.
💡 Take clear photos of the inverter screen, serial number, fault code, and switch positions before you reset. This saves time if support is needed.
💡 Keep the inverter manual bookmarked on your phone. Brand-specific sequences can differ slightly between models.
💡 If you have a hybrid or battery-ready system, look for a separate battery status message before assuming the solar inverter is the only problem.
💡 If solar output looks low, compare it to the time of day and weather. A successful reset at 7:00 pm may still show zero generation because there is not enough sunlight.

Recommended Tools

Ledlenser MH5 or similar rechargeable headlamp — makes it easier to read inverter screens and switchboard labels in garages or side paths.
Brady lockout/tagout tag kit — useful if the inverter must remain isolated while waiting for service.
Fluke T5-600 electrical tester — a reliable diagnostic tool for a licensed electrician checking AC supply issues.
Manufacturer monitoring app such as Fronius Solar.web, Sungrow iSolarCloud, or GoodWe SEMS Portal — often the quickest way to identify whether the inverter is in standby, fault, or reconnect mode.

Frequently asked questions

How do you reset a solar inverter after a blackout?
To reset a solar inverter, turn off the Solar Supply Main Switch on the switchboard, switch off the inverter AC isolator, and turn the DC isolator to the off position. Wait five minutes, then reverse the sequence: turn on the DC isolator, AC isolator, and Solar Supply Main Switch.
Why does a solar inverter take so long to turn on after an outage?
Australian Standard AS/NZS 4777.2 requires solar inverters to monitor grid voltage and frequency for 60 to 300 seconds before reconnecting. This mandatory anti-islanding delay ensures the mains grid is completely stable and safe before the inverter exports power, preventing electrical hazards for network line workers.
Can an Australian homeowner safely reset their own solar inverter?
Homeowners can operate external AC and DC isolator switches to reset an inverter if the switches are clearly labelled and accessible. However, testing internal wiring or opening system enclosures is restricted electrical work under AS/NZS 3000:2018 (Wiring Rules) and must be carried out by a licensed electrical contractor.
What should I do if the solar inverter shows an isolation fault after resetting?
An isolation fault or 'earth fault' indicates electrical leakage between the DC array and ground, often triggered by moisture ingress or damaged cabling. Do not touch the inverter or rooftop switches. Keep the system shut down and immediately engage an accredited Clean Energy Council solar electrician for diagnostics.
Why is the DC isolator hard to switch or making a crackling noise?
A stiff or noisy DC isolator points to internal component degradation, moisture ingress, or dangerous electrical arcing across high-voltage contacts. Never force a jammed isolator switch. Leave the switchboard AC solar breaker turned off, stay clear of the unit, and call a licensed sparky to replace the faulty isolator.

Written by Sparky, the Electrical specialist at VIC.Tools.